scholarly journals Experimental Study on Active Cooling Systems Used for Thermal Management of High-Power Multichip Light-Emitting Diodes

2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Mehmet Kaya

The objective of this study was to develop suitable cooling systems for high-power multichip LEDs. To this end, three different active cooling systems were investigated to control the heat generated by the powering of high-power multichip LEDs in two different configurations (30 and 2 × 15 W). The following cooling systems were used in the study: an integrated multi-fin heat sink design with a fan, a cooling system with a thermoelectric cooler (TEC), and a heat pipe cooling device. According to the results, all three systems were observed to be sufficient for cooling high-power LEDs. Furthermore, it was observed that the integrated multifin heat sink design with a fan was the most efficient cooling system for a 30 W high-power multichip LED. The cooling system with a TEC and 46 W input power was the most efficient cooling system for 2 × 15 W high-power multichip LEDs.

2013 ◽  
Vol 284-287 ◽  
pp. 768-772 ◽  
Author(s):  
Rong Yuan Jou

High-power light emitting diode (LED) modules offer several advantages over conventional light sources, but require effective thermal management for optimal performance, such as liquid cooling or thermoelectric cooling (TEC). This study compared the thermal performance of high-power LEDs with liquid cooling and TEC using both the finite element method and experiments. We considered a mutichip module in which the LEDs are immersed in one of three different cooling fluids in a metal enclosure with passive cooling or a TEC module. In the experiments, temperatures were measured by thermocouples. The temperature and flow fields of the liquid-cooled package inside the enclosure were analyzed in detail using a numerical model, and the results were validated against the experimental measurements. In this paper, we discuss the major design considerations when using liquid cooling and TEC. Our results show that for the illumination module considered in this study, appropriate heat sink design is crucial to optimizing performance with TEC, which can enhance the heat dissipation for small and compact LED modules.


2011 ◽  
Vol 50-51 ◽  
pp. 278-282
Author(s):  
J.H. Xiang ◽  
Xiao Chu Liu ◽  
Chun Liang Zhang ◽  
Yong Tang

A novel heat sink was fabricated for packaging cooling of high power LED. Enhanced boiling structures in the evaporation surface were processed by ploughing-extrusion (P-E) and stamping methods, respectively. The cycle power of refrigerant was supplied by wick of sintered copper powder on internal surface of phase change heat sink. The experimental results showed that phase change heat sink was provided with a good heat transfer capability and the temperature of phase change heat sink reached 86.8°C under input power of 10W LED at ambient temperature of 20°C.


2010 ◽  
Vol 57 (9) ◽  
pp. 2203-2207 ◽  
Author(s):  
Ray-Hua Horng ◽  
Jhih-Sin Hong ◽  
Yu-Li Tsai ◽  
Dong-Sing Wuu ◽  
Chih-Ming Chen ◽  
...  

2014 ◽  
Vol 3 (5-6) ◽  
Author(s):  
Roland Lachmayer ◽  
Alexander Wolf ◽  
Gerolf Kloppenburg

AbstractFor many lighting applications, light-emitting diodes (LEDs) are replacing traditional light sources providing the possibility for smart and efficient systems as well as a reduction in the product weight. A next step in this development is the integration of laser-based light sources to increase luminance and to further scale down the optics possibly leading to a reduction of necessary resources. This article reviews the possibilities and challenges arising from the use of laser diodes especially compared to current high-power LED systems in terms of efficiency, color-rendering properties, and thermal management.


Author(s):  
Tianyi Gao ◽  
James Geer ◽  
Bahgat G. Sammakia ◽  
Russell Tipton ◽  
Mark Seymour

Cooling power constitutes a large portion of the total electrical power consumption in data centers. Approximately 25%∼40% of the electricity used within a production data center is consumed by the cooling system. Improving the cooling energy efficiency has attracted a great deal of research attention. Many strategies have been proposed for cutting the data center energy costs. One of the effective strategies for increasing the cooling efficiency is using dynamic thermal management. Another effective strategy is placing cooling devices (heat exchangers) closer to the source of heat. This is the basic design principle of many hybrid cooling systems and liquid cooling systems for data centers. Dynamic thermal management of data centers is a huge challenge, due to the fact that data centers are operated under complex dynamic conditions, even during normal operating conditions. In addition, hybrid cooling systems for data centers introduce additional localized cooling devices, such as in row cooling units and overhead coolers, which significantly increase the complexity of dynamic thermal management. Therefore, it is of paramount importance to characterize the dynamic responses of data centers under variations from different cooling units, such as cooling air flow rate variations. In this study, a detailed computational analysis of an in row cooler based hybrid cooled data center is conducted using a commercially available computational fluid dynamics (CFD) code. A representative CFD model for a raised floor data center with cold aisle-hot aisle arrangement fashion is developed. The hybrid cooling system is designed using perimeter CRAH units and localized in row cooling units. The CRAH unit supplies centralized cooling air to the under floor plenum, and the cooling air enters the cold aisle through perforated tiles. The in row cooling unit is located on the raised floor between the server racks. It supplies the cooling air directly to the cold aisle, and intakes hot air from the back of the racks (hot aisle). Therefore, two different cooling air sources are supplied to the cold aisle, but the ways they are delivered to the cold aisle are different. Several modeling cases are designed to study the transient effects of variations in the flow rates of the two cooling air sources. The server power and the cooling air flow variation combination scenarios are also modeled and studied. The detailed impacts of each modeling case on the rack inlet air temperature and cold aisle air flow distribution are studied. The results presented in this work provide an understanding of the effects of air flow variations on the thermal performance of data centers. The results and corresponding analysis is used for improving the running efficiency of this type of raised floor hybrid data centers using CRAH and IRC units.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Krzysztof Posobkiewicz ◽  
Krzysztof Górecki

Purpose The purpose of this study is to investigate the validation of the usefulness of cooling systems containing Peltier modules for cooling power devices based on measurements of the influence of selected factors on the value of thermal resistance of such a cooling system. Design/methodology/approach A cooling system containing a heat-sink, a Peltier module and a fan was built by the authors and the measurements of temperatures and thermal resistance in various supply conditions of the Peltier module and the fan were carried out and discussed. Findings Conclusions from the research carried out answer the question if the use of Peltier modules in active cooling systems provides any benefits comparing with cooling systems containing just passive heat-sinks or conventional active heat-sinks constructed of a heat-sink and a fan. Research limitations/implications The research carried out is the preliminary stage to asses if a compact thermal model of the investigated cooling system can be formulated. Originality/value In the paper, the original results of measurements and calculations of parameters of a cooling system containing a Peltier module and an active heat-sink are presented and discussed. An influence of power dissipated in the components of the cooling system on its efficiency is investigated.


Author(s):  
Sangmesh ◽  
◽  
Gopalakrishna Keshava Narayana ◽  
Manjunath Shiraganhalli Honnaiah ◽  
Krishna Venkatesh ◽  
...  

2011 ◽  
Vol 687 ◽  
pp. 215-221
Author(s):  
Yuan Yuan Han ◽  
Hong Guo ◽  
Xi Min Zhang ◽  
Fa Zhang Yin ◽  
Ke Chu ◽  
...  

With increasing of the input power of the chips in light emitting diode (LED), the thermal accumulation of LEDs package increases. Therefore solving the heat issue has become a precondition of high power LED application. In this paper, finite element method was used to analyze the thermal field of high power LEDs. The effect of the heatsink structure on the junction temperature was also investigated. The results show that the temperature of the chip is 95.8°C which is the highest, and it meets the requirement. The conductivity of each component affects the thermal resistance. Convective heat exchange is connected with the heat dissipation area. In the original structure of LEDs package the heat convected through the substrate is the highest, accounting for 92.58%. Three heatsinks with fin structure are designed to decrease the junction temperature of the LEDs package.


2012 ◽  
Author(s):  
Ming-Seng Hsu ◽  
Jen-Wei Huang ◽  
Feng-Lin Shyu