scholarly journals Analytical Analysis of Seismic Behavior of Cold-Formed Steel Frames with Strap Brace and Sheathings Plates

2014 ◽  
Vol 2014 ◽  
pp. 1-22 ◽  
Author(s):  
M. Gerami ◽  
M. Lotfi

Cold-formed steel frames (CFS) are popular all over the world. In this study, we have investigated 112 frames with different bracing arrangements and different dimensional ratios with different thicknesses of sheathing plates under cyclic and monotonic loading using Finite Element Nonlinear Analysis. We also evaluated seismic parameters including resistance reduction factor, ductility, and force reduction factor due to ductility for all specimens. On the other hand, we calculated the seismic response modification factor for these systems. The maximum modification factor among shear wall panels with sheathing plates related to GWB (gypsum wall board) specimen with thickness of 15 mm was 5.14; among bracing specimens in bilateral bracing mode related to B sample was 3.14. The maximum amount of resistance among the specimens with bilateral (2-side) bracing systems belongs to the specimen C (2-side double X-bracing) with the dimension ratio of 2 (4.8 m × 2.4 m) and resistance of 305.60 kN and also among the shear wall panels with sheathing plates, it belongs to DFP (douglas fir plywood) with a thickness of 20 mm and resistance of 371.34 kN.

1993 ◽  
Vol 9 (1) ◽  
pp. 121-135 ◽  
Author(s):  
Chia-Ming Uang

The two-level design philosophy is recognized by modern seismic codes. When this philosophy is implemented in the code, the intensities of the two design earthquakes, the structural performance criteria, explicit versus implicit design approach, and the effectiveness to achieve the performance criteria vary considerably from one code to the other. For the ultimate limit state, the UBC was compared with seismic codes of Canada, Japan, and Eurocode. It was found that a trend to deviate from the UBC approach of using a single seismic force reduction factor (i.e., Rw) is apparent. Instead, an approach using a compound force reduction factor which considers the contribution of structural ductility and structural overstrength is preferred. For the serviceability limit state, a comparison of the level of design earthquakes and performance criteria of the UBC, Tri-Services Manual, and the Japanese code indicates that the UBC produces the most flexible structure, and that UBC does not control structural damage. It is suggested that the UBC adopts an explicit serviceability design procedure.


2006 ◽  
Vol 22 (1) ◽  
pp. 267-286 ◽  
Author(s):  
Jorge L. Varela ◽  
Jennifer E. Tanner ◽  
Richard E. Klingner

This paper addresses the development and application of a rational procedure to select the seismic force reduction factor ( R) and the displacement amplification factor ( Cd) for the design of autoclaved aerated concrete (AAC) structures. The values of R and Cd are proposed based on a combination of laboratory test results and numerical simulation. The test results are obtained from 14 AAC shear-wall specimens tested under simulated gravity and quasi-static reversed cyclic lateral loads. Analytical responses are predicted using nonlinear analysis models whose hysteretic characteristics are based on the experimentally observed responses. Using an iterative procedure, typical AAC structures are designed using successively larger trial values of the factor, R, until the structure's response (either ductility or drift) exceeds the experimentally determined capacity. A lower fractile of those critical values, modified for probable structural overstrength, is taken as a reasonable value of 3 for R. Using an analogous procedure, a reasonable value of Cd is determined as 3. These values will undoubtedly be refined based on field experience, just as they have been for other structural systems.


Author(s):  
J. B. Berrill ◽  
M. J. N. Priestley ◽  
R. Peek

This paper provides background material to the loadings section
of the model code recently published by the Society's Discussion Group
on Bridge Design, and presents a preliminary re-evaluation of the design spectra given in the proposed code. The basis for the proposed zoning scheme, in which the present uniform Zone B is replaced by a transition zone, is discussed. Arguments are given underlying the return period coefficients, and the force reduction factor used in generating the inelastic response spectra of the code. It is likely that the design spectra and the values of the other coefficients determining base shear forces will need to be revised as further research results become available; however, the form of the base shear expression, and the loadings section
as a whole, should remain unchanged. Re-evaluated spectra suggest that
the seismic coefficient values given in the proposed code may be too large by about 25 percent in Zone A, and too low by as much as 40 percent in
 Zone C. While the reassessed values should be more reliable than the original ones, they are based on a Japanese attenuation model, which has
not yet been calibrated against New Zealand data. Further research is required to establish an appropriate attenuation model for New Zealand;
 to avoid undue proliferation of design loadings it is preferable to defer revision of the various coefficients in the proposed code until such a
model is available. Until this is done, the proposed spectra should be viewed with caution, particularly in Zone C.


Sign in / Sign up

Export Citation Format

Share Document