Use of formalin-fixed tissues for ex-vivo imaging with optical coherence tomography (OCT)

2006 ◽  
Author(s):  
Sonya Shortkroff ◽  
Alicia Goodwin ◽  
Susanne Giattina ◽  
Bin Liu ◽  
Mark E. Brezinski
2017 ◽  
Author(s):  
Peijun Gong ◽  
Karol Karnowski ◽  
Paula Yu ◽  
Dong An ◽  
Dao-Yi Yu ◽  
...  

2007 ◽  
Vol 39 (1) ◽  
pp. 28-35 ◽  
Author(s):  
Nigel R. Munce ◽  
Victor X.D. Yang ◽  
Beau A. Standish ◽  
Beiping Qiang ◽  
Jagdish Butany ◽  
...  

2013 ◽  
Vol 195 (1) ◽  
pp. 25-27 ◽  
Author(s):  
T. Tschernig ◽  
L. Thrane ◽  
T.M. Jørgensen ◽  
J. Thommes ◽  
R. Pabst ◽  
...  

2010 ◽  
Vol 15 (1) ◽  
pp. 016001 ◽  
Author(s):  
Chao Zhou ◽  
Yihong Wang ◽  
Aaron D. Aguirre ◽  
Tsung-Han Tsai ◽  
David W. Cohen ◽  
...  

2005 ◽  
Vol 62 (4) ◽  
pp. 561-574 ◽  
Author(s):  
Pei-Lin Hsiung ◽  
Liron Pantanowitz ◽  
Aaron D. Aguirre ◽  
Yu Chen ◽  
Darshan Phatak ◽  
...  

The Analyst ◽  
2020 ◽  
Vol 145 (4) ◽  
pp. 1445-1456 ◽  
Author(s):  
Fabian Placzek ◽  
Eliana Cordero Bautista ◽  
Simon Kretschmer ◽  
Lara M. Wurster ◽  
Florian Knorr ◽  
...  

Characterization of bladder biopsies, using a combined fiber optic probe-based optical coherence tomography and Raman spectroscopy imaging system that allows a large field-of-view imaging and detection and grading of cancerous bladder lesions.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Bhoite ◽  
H Jinnouchi ◽  
F Otsuka ◽  
Y Sato ◽  
A Sakamoto ◽  
...  

Abstract Background In many studies, struts coverage is defined as >0 mm of tissue overlying the stent struts by optical coherence tomography (OCT). However, this definition has never been validated using histology as the “gold standard”. The present study sought to assess the appropriate cut-off value of neointimal thickness of stent strut coverage by OCT using histology. Methods OCT imaging was performed on 39 human coronary arteries with stents from 25 patients at autopsy. A total of 165 cross-sectional images from 46 stents were co-registered with histology. The optimal cut-off value of strut coverage by OCT was determined. Strut coverage by histology was defined as endothelial cells with at least underlying two layers of smooth muscle cells. Considering the resolution of OCT is 10–20 μm, 3 different cut-off values (i.e. at ≥20, ≥40, and ≥60 μm) were assessed. Results A total of 2235 struts were evaluated by histology. Eventually, 1216 struts which were well-matched struts were analyzed in this study. By histology, uncovered struts were observed in 160 struts and covered struts were observed in 1056 struts. The broadly used definition of OCT-coverage which does not consider neointimal thickness yielded a poor specificity of 37.5% and high sensitivity 100%. Of 3 cut-off values, the cut-off value of >40 μm was more accurate as compared to >20 and >60 mm [sensitivity (99.3%), specificity (91.0%), positive predictive value (98.6%), and negative predictive value (95.6%)] Conclusion The most accurate cut-off value was ≥40 μm neointimal thickness by OCT in order to identify stent strut coverage validated by histology. Funding Acknowledgement Type of funding source: None


2002 ◽  
Vol 30 (3) ◽  
pp. 209-215 ◽  
Author(s):  
Hans Hoerauf ◽  
J�rg Winkler ◽  
Christian Scholz ◽  
Christopher Wirbelauer ◽  
Roswitha S. Gordes ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document