Transscleral optical coherence tomography?An experimental study in ex-vivo human eyes

2002 ◽  
Vol 30 (3) ◽  
pp. 209-215 ◽  
Author(s):  
Hans Hoerauf ◽  
J�rg Winkler ◽  
Christian Scholz ◽  
Christopher Wirbelauer ◽  
Roswitha S. Gordes ◽  
...  
2011 ◽  
Vol 125 (5) ◽  
pp. 467-473 ◽  
Author(s):  
T Just ◽  
T Zehlicke ◽  
O Specht ◽  
W Sass ◽  
C Punke ◽  
...  

AbstractObjective:We report an ex vivo and in vivo experimental study of a device designed to measure tympanic membrane movement under normal and pathological conditions, assessed using optical coherence tomography.Materials and methods:We designed two types of flexible, round film patch with integrated strain gauge, to be attached to the tympanic membrane in order to measure tympanic membrane movement. Tympanic membrane attachment was assessed using optical coherence tomography. The devices were tested experimentally using an ex vivo model with varying middle-ear pressure.Results:Optical coherence tomography reliably assessed attachment of the film patch to the tympanic membrane, before and after middle-ear pressure changes. Strain gauge voltage changes were directly proportional to middle-ear pressure recordings, for low pressure changes. Tympanic membrane perforations smaller than 2 mm could be sealed off with the film patch.Conclusion:Attachment of the film patch with integrated strain gauge to the tympanic membrane was not ideal. Nevertheless, the strain gauge was able to precisely detect small pressure changes within the middle ear, in this experimental model.


2021 ◽  
Author(s):  
Ian Rubinoff ◽  
Roman V Kuranov ◽  
Zeinab Ghassabi ◽  
Yuanbo Wang ◽  
Lisa Beckmann ◽  
...  

Alterations in the retinal oxygen saturation (sO2) and oxygen consumption are associated with nearly all blinding diseases. A technology that can accurately measure retinal sO2 has the potential to improve ophthalmology care significantly. Recently, visible-light optical coherence tomography (vis-OCT) showed great promise for noninvasive, depth-resolved measurement of retinal sO2 as well as ultra-high resolution anatomical imaging. We discovered that spectral contaminants (SC), if not correctly removed, could lead to incorrect vis-OCT sO2 measurements. There are two main types of SCs associated with vis-OCT systems and eye conditions, respectively. Their negative influence on sO2 accuracy is amplified in human eyes due to stringent laser power requirements, eye motions, and varying eye anatomies. We developed an adaptive spectroscopic vis-OCT (Ads-vis-OCT) method to iteratively remove both types of SCs. We validated Ads-vis-OCT in ex vivo bovine blood samples against a blood-gas analyzer. We further validated Ads-vis-OCT in 125 unique retinal vessels from 18 healthy subjects against pulse-oximeter readings, setting the stage for clinical adoption of vis-OCT.


The Analyst ◽  
2020 ◽  
Vol 145 (4) ◽  
pp. 1445-1456 ◽  
Author(s):  
Fabian Placzek ◽  
Eliana Cordero Bautista ◽  
Simon Kretschmer ◽  
Lara M. Wurster ◽  
Florian Knorr ◽  
...  

Characterization of bladder biopsies, using a combined fiber optic probe-based optical coherence tomography and Raman spectroscopy imaging system that allows a large field-of-view imaging and detection and grading of cancerous bladder lesions.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Bhoite ◽  
H Jinnouchi ◽  
F Otsuka ◽  
Y Sato ◽  
A Sakamoto ◽  
...  

Abstract Background In many studies, struts coverage is defined as >0 mm of tissue overlying the stent struts by optical coherence tomography (OCT). However, this definition has never been validated using histology as the “gold standard”. The present study sought to assess the appropriate cut-off value of neointimal thickness of stent strut coverage by OCT using histology. Methods OCT imaging was performed on 39 human coronary arteries with stents from 25 patients at autopsy. A total of 165 cross-sectional images from 46 stents were co-registered with histology. The optimal cut-off value of strut coverage by OCT was determined. Strut coverage by histology was defined as endothelial cells with at least underlying two layers of smooth muscle cells. Considering the resolution of OCT is 10–20 μm, 3 different cut-off values (i.e. at ≥20, ≥40, and ≥60 μm) were assessed. Results A total of 2235 struts were evaluated by histology. Eventually, 1216 struts which were well-matched struts were analyzed in this study. By histology, uncovered struts were observed in 160 struts and covered struts were observed in 1056 struts. The broadly used definition of OCT-coverage which does not consider neointimal thickness yielded a poor specificity of 37.5% and high sensitivity 100%. Of 3 cut-off values, the cut-off value of >40 μm was more accurate as compared to >20 and >60 mm [sensitivity (99.3%), specificity (91.0%), positive predictive value (98.6%), and negative predictive value (95.6%)] Conclusion The most accurate cut-off value was ≥40 μm neointimal thickness by OCT in order to identify stent strut coverage validated by histology. Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Peijun Tang ◽  
Mitchell A. Kirby ◽  
Nhan Le ◽  
Yuandong Li ◽  
Nicole Zeinstra ◽  
...  

AbstractCollagen organization plays an important role in maintaining structural integrity and determining tissue function. Polarization-sensitive optical coherence tomography (PSOCT) is a promising noninvasive three-dimensional imaging tool for mapping collagen organization in vivo. While PSOCT systems with multiple polarization inputs have demonstrated the ability to visualize depth-resolved collagen organization, systems, which use a single input polarization state have not yet demonstrated sufficient reconstruction quality. Herein we describe a PSOCT based polarization state transmission model that reveals the depth-dependent polarization state evolution of light backscattered within a birefringent sample. Based on this model, we propose a polarization state tracing method that relies on a discrete differential geometric analysis of the evolution of the polarization state in depth along the Poincare sphere for depth-resolved birefringent imaging using only one single input polarization state. We demonstrate the ability of this method to visualize depth-resolved myocardial architecture in both healthy and infarcted rodent hearts (ex vivo) and collagen structures responsible for skin tension lines at various anatomical locations on the face of a healthy human volunteer (in vivo).


2009 ◽  
Vol 47 (7) ◽  
pp. e51-e52
Author(s):  
Zaid Hamdoon ◽  
Waseem Jerjes ◽  
Tahwinder Upile ◽  
Gordon McKenzie ◽  
Christian S. Betz ◽  
...  

2010 ◽  
Author(s):  
A. Vázquez Villa ◽  
J. A. Delgado Atencio ◽  
S. Vázquez y Montiel ◽  
M. Cunill Rodríguez ◽  
A. E. Martínez Rodríguez ◽  
...  