Multifrequency-swept optical coherence microscopy for full-field in-vivo intracochlear vibration measurement

Author(s):  
Samuel Choi ◽  
Fumiaki Nin ◽  
Takeru Ota ◽  
Hiroshi Hibino
2019 ◽  
Vol 9 (2) ◽  
pp. 216 ◽  
Author(s):  
Manabu Sato ◽  
Kai Eto ◽  
Junpei Masuta ◽  
Kenji Inoue ◽  
Reiko Kurotani ◽  
...  

We demonstrate full-field optical coherence microscopy (OCM) using an ultrathin forward-imaging short multimode fiber (SMMF) probe with a core diameter of 50 μm, outer diameter of 125 μm, and length of 7.4 mm, which is a typical graded-index multimode fiber used for optical communications. The axial and lateral resolutions were measured to be 2.14 μm and 2.3 μm, respectively. By inserting the SMMF 4 mm into the cortex of an in vivo rat brain, scanning was performed to a depth of 147 μm from the SMMF facet with a field of view of 47 μm. Three-dimensional (3D) OCM images were obtained at depths ranging from approximately 20 μm to 90 μm. Based on the morphological information of the resliced 3D images and the dependence of the integration of the OCM image signal on the insertion length, the obtained 3D information of nerve fibers has been presented.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Jun Zhu ◽  
Hercules Rezende Freitas ◽  
Izumi Maezawa ◽  
Lee-way Jin ◽  
Vivek J. Srinivasan

AbstractIn vivo, minimally invasive microscopy in deep cortical and sub-cortical regions of the mouse brain has been challenging. To address this challenge, we present an in vivo high numerical aperture optical coherence microscopy (OCM) approach that fully utilizes the water absorption window around 1700 nm, where ballistic attenuation in the brain is minimized. Key issues, including detector noise, excess light source noise, chromatic dispersion, and the resolution-speckle tradeoff, are analyzed and optimized. Imaging through a thinned-skull preparation that preserves intracranial space, we present volumetric imaging of cytoarchitecture and myeloarchitecture across the entire depth of the mouse neocortex, and some sub-cortical regions. In an Alzheimer’s disease model, we report that findings in superficial and deep cortical layers diverge, highlighting the importance of deep optical biopsy. Compared to other microscopic techniques, our 1700 nm OCM approach achieves a unique combination of intrinsic contrast, minimal invasiveness, and high resolution for deep brain imaging.


2020 ◽  
Vol 11 (2) ◽  
pp. 711 ◽  
Author(s):  
Cristina Canavesi ◽  
Andrea Cogliati ◽  
Amanda Mietus ◽  
Yue Qi ◽  
Jesse Schallek ◽  
...  

2012 ◽  
Vol 37 (23) ◽  
pp. 4937 ◽  
Author(s):  
Stefan E. Schausberger ◽  
Bettina Heise ◽  
Swanhild Bernstein ◽  
David Stifter

2015 ◽  
Vol 54 (27) ◽  
pp. 8212 ◽  
Author(s):  
Antoine Federici ◽  
Henrique S. Gutierrez da Costa ◽  
Jonas Ogien ◽  
Audrey K. Ellerbee ◽  
Arnaud Dubois

Sign in / Sign up