Use Condition Characterization of Package Components

Author(s):  
Leigh Wojewoda ◽  
Dhanya Athreya ◽  
Michael J. Hill

Discrete components, such as capacitors and inductors, play an important role in the analysis and design of electronic packages and printed circuit boards. Although the electrical parameters of discrete components are described by manufacturers, the component performance at product operating conditions can vary drastically from the manufacturer’s specification. Accurate characterization of discrete package components at operating conditions is essential to understand product operation. This paper will introduce a method to characterize discrete capacitors and inductors while applying multiple operating conditions simultaneously. Several inductor options will be evaluated, including a newly introduced metal composite component.

2016 ◽  
Vol 65 (8) ◽  
pp. 1827-1835 ◽  
Author(s):  
Marco Lorenzo Valerio Tagliaferri ◽  
Alessandro Crippa ◽  
Simone Cocco ◽  
Marco De Michielis ◽  
Marco Fanciulli ◽  
...  

2005 ◽  
Vol 127 (4) ◽  
pp. 370-374 ◽  
Author(s):  
X. B. Chen

In electronics packaging, one of the key processes is dispensing fluid materials, such as adhesive, epoxy, encapsulant, onto substrates or printed circuit boards for the purpose of surface mounting or encapsulation. In order to precisely control the dispensing process, the understanding and characterization of the flow behavior of the fluid being dispensed is very important, as the behavior can have a significant influence on the dispensing process. However, this task has proven to be very challenging due to the fact that the fluids for electronics packaging usually exhibit the time-dependent rheological behavior, which has not been well defined in literature. In the paper a study on the characterization of the time-dependent rheological behavior of the fluids for electronics packaging is presented. In particular, a model is developed based on structural theory and then applied to the characterization of the decay and recovery of fluid behavior, which happen in the dispensing process due to the interruption of process. Experiments are carried out to verify the effectiveness of the model developed.


Author(s):  
Jimil M. Shah ◽  
Roshan Anand ◽  
Satyam Saini ◽  
Rawhan Cyriac ◽  
Dereje Agonafer ◽  
...  

Abstract A remarkable amount of data center energy is consumed in eliminating the heat generated by the IT equipment to maintain and ensure safe operating conditions and optimum performance. The installation of Airside Economizers, while very energy efficient, bears the risk of particulate contamination in data centers, hence, deteriorating the reliability of IT equipment. When RH in data centers exceeds the deliquescent relative humidity (DRH) of salts or accumulated particulate matter, it absorbs moisture, becomes wet and subsequently leads to electrical short circuiting because of degraded surface insulation resistance between the closely spaced features on printed circuit boards. Another concern with this type of failure is the absence of evidence that hinders the process of evaluation and rectification. Therefore, it is imperative to develop a practical test method to determine the DRH value of the accumulated particulate matter found on PCBs (Printed Circuit Boards). This research is a first attempt to develop an experimental technique to measure the DRH of dust particles by logging the leakage current versus RH% (Relative Humidity percentage) for the particulate matter dispensed on an interdigitated comb coupon. To validate this methodology, the DRH of pure salts like MgCl2, NH4NO3 and NaCl is determined and their results are then compared with their published values. This methodology was therefore implemented to help lay a modus operandi of establishing the limiting value or an effective relative humidity envelope to be maintained at a real-world data center facility situated in Dallas industrial area for its continuous and reliable operation.