Design of a Biomimetic Directional Microphone Diaphragm

2000 ◽  
Author(s):  
C. Gibbons ◽  
R. N. Miles

Abstract A miniature silicon condenser microphone diaphragm has been designed that exhibits good predicted directionality, sensitivity, and reliability. The design was based on the structure of a fly’s ear (Ormia ochracea) that has highly directional hearing through mechanical coupling of the eardrums. The diaphragm that is 1mm × 2mm × 20 microns is intended to be fabricated out of polysilicon through microelectromechanical micromachining. It was designed through the finite-element method in ANSYS in order to build the necessary mode shapes and frequencies into the mechanical behavior of the design. Through postprocessing of the ANSYS data, the diaphragm’s response to an arbitrary sound source, sensitivity, robustness, and Articulation Index - Directivity Index (AI-DI) were predicted. The design should yield a sensitivity as high as 100 mV/Pa, an AI-DI of 4.764 with Directivity Index as high as 6 between 1.5 and 5 kHz. The diaphragm structure was predicted be able to withstand a sound pressure level of 151.74 dB. The sound level that would result in collapse of the capacitive sensor is 129.9 dB.. The equivalent sound level due to the self-noise of the microphone is predicted to be 30.8 dBA.

2014 ◽  
Vol 1001 ◽  
pp. 171-176 ◽  
Author(s):  
Pavol Liptai ◽  
Marek Moravec ◽  
Miroslav Badida

This paper describes possibilities in the use of recycled rubber granules and textile materials combined with vermiculite panel. The aim of the research is the application of materials that will be absorbing or reflecting sound energy. This objective is based on fundamental physical principles of materials research and acoustics. Method of measurement of sound absorption coefficient is based on the principle of standing wave in the impedance tube. With a sound level meter is measured maximum and minimum sound pressure level of standing wave. From the maximum and minimum sound pressure level of standing wave is calculated sound absorption coefficient αn, which can take values from 0 to 1. Determination of the sound absorption coefficient has been set in 1/3 octave band and in the frequency range from 50 Hz to 2000 Hz. In conclusion are proposed possibilities of application of these materials in terms of their mechanical and physical parameters.


Author(s):  
Mohammad Javad Zare Sakhvidi ◽  
Hamideh Bidel ◽  
Ahmad Ali Kheirandish

 Background: Chronic occupational exposure to noise is an unavoidable reality in the country's textile industry and even other countries. The aim of this study was to compare the sound pressure level in different parts of the textile industry in Yazd and in different parts of the textile industry. Methods: This cross-sectional study was performed on 930 textile workers in Yazd. A questionnaire was used to obtain demographic information and how to use protective equipment. Then, to obtain the sound pressure level of each unit and device and to use the measurement principles, a calibrated sound level meter was used. Then the results were analyzed using SPSS Ver.29 software. Results: The participants in this study were 714 males and 216 females with a mean age of 35.27 and 33.63 years, respectively. Seven hundred fifty-six participants (81.29%) were exposed to sound pressure levels higher than 85 dB. Among the participants, only 18.39% of the people used a protective phone permanently. Except for factory E, with an average sound pressure level of 77.78 dB, the rest of the factories had an average sound pressure level higher than the occupational exposure limit. The sound measurement results of different devices show that the sound pressure levels above 90 dB are related to the parts of Dolatab, Ring, Kinetting (knitting), Chanel, Autoconer, Dolakni, Open End, MultiLakni, Tabandegi, Texture, and Poy. Conclusion: Based on the results of the present study, noise above 90 dB is considered as one of the main risk factors in most parts of the textile industry (spinning and weaving), which in the absence of engineering, managerial or individual controls on it causes hearing loss in becoming employees of this industry


2002 ◽  
Vol 33 (8) ◽  
pp. 16-24
Author(s):  
Jesús Alba Fernández ◽  
Marcelino Ferri García ◽  
Jaime Ramis Soriano ◽  
Juan Antonio Martínez Mora

In environmental acoustics the knowledge of the time dependency of the sound level provides relevant information about a sound event. In this sense, it may be said that conventional sound level metres have frequently implemented programs to calculate the fractiles (percentiles) of the distribution of instantaneous sound levels; and there are several indexes to evaluate the noise pollution, based on different statistical parameters. For further analysis of sound, and to obtain the commented indexes, it is accepted that this distribution is normal or gaussian. The questions we've tried to solve in this work are the following: First of all, whether the time dependent distribution of the variable sound pressure level should be considered as Gaussian in general cases or only in some particular ones. On the other hand, we have studied how the frequency of the sampling affects the resulting distribution of a given a sound event. To these ends, a set of road traffic noise events has been evaluated. Furthermore, even in gaussian distributions of sound pressure levels, the average of the distribution will not be coincident with the equivalent sound pressure level; that is the level of the average quadratic pressure. The difference between this parameter, and its dependence on the standard deviation, is studied.


2000 ◽  
Vol 34 (2) ◽  
pp. 136-144 ◽  
Author(s):  
E. Böjrk ◽  
T. Nevalainen ◽  
M. Hakumäki ◽  
H.-M. Voipio

Since sounds may induce physiological and behavioural changes in animals, it is necessary to assess and define the acoustic environment in laboratory animal facilities. Sound studies usually express sound levels as unweighted linear sound pressure levels. However, because a linear scale does not take account of hearing sensitivity-which may differ widely both between and within species at various frequencies-the results may be spurious. In this study a novel sound pressure level weighting for rats, R-weighting, was calculated according to a rat's hearing sensitivity. The sound level of a white noise signal was assessed using R-weighting, with H-weighting tailored for humans, A-weighting and linear sound pressure level combined with the response curves of two different loudspeakers. The sound signal resulted in different sound levels depending on the weighting and the type of loudspeaker. With a tweeter speaker reproducing sounds at high frequencies audible to a rat, R- and A-weightings gave similar results, but the H-weighted sound levels were lower. With a middle-range loudspeaker, unable to reproduce high frequencies, R-weighted sound showed the lowest sound levels. In conclusion, without a correct weighting system and proper equipment, the final sound level of an exposure stimulus can differ by several decibels from that intended. To achieve reliable and comparable results, standardization of sound experiments and assessment of the environment in animal facilities is a necessity. Hence, the use of appropriate species-specific sound pressure level weighting is essential. R-weighting for rats in sound studies is recommended.


2008 ◽  
Vol 22 (11) ◽  
pp. 1087-1092 ◽  
Author(s):  
DA LIE PEI ◽  
YONGRAE ROH

Underwater Tonpilz transducer is designed with 1-3 piezocomposite materials to overcome the problems with conventional piezoceramic transducers. With the FEM, the variation of the resonance frequency, bandwidth and sound pressure of the transducer are analyzed in relation to the structural variables of the transducer. Through statistical multiple regression analysis of the results, functional forms of the transducer performance are derived in terms of design variables. By applying the constrained optimization technique, SQP-PD, to the derived functions, the optimal structure of the transducer is determined that can provide the highest sound pressure level at a given resonant frequency over a pre-determined frequency range. The validity of the optimized results is confirmed through comparison of the optimal performance with that of the FEA.


2015 ◽  
Vol 21 (4) ◽  
pp. 28-34
Author(s):  
IULIANA IAȘNICU (STAMATE) ◽  
OVIDIU VASILE ◽  
RADU IATAN

Plates known as sound absorbing materials: textiles recovered fabrics plus polyethylene are made layered composite material intended to be used to encapsulate industrial engines, as sources of noise in the production departments. Influence of thickness sound-absorbing material can be supported by the values obtained for the absorption coefficient, but it can be studied as a study case in the anechoic chamber, where the sound pressure level is measured with a sound level meter. Cases captured: a free engine; the engine placed in a metallic cube and motor inserted; metal cube that was doubled separately with one material and then with the composite material proposed. For each situation are eight determinations on the perimeter of a circle with a radius of one meter from the source of the noise. Plot a graph of experimental results that support the idea: greater thickness of the layer of material will cause a better absorption of noise.


2012 ◽  
Vol 562-564 ◽  
pp. 1163-1167
Author(s):  
Feng Qiang Zhao ◽  
Guang Qiang Li ◽  
Hong Ying Hu ◽  
Jia Lu Du ◽  
Chen Guo

At present, the common method of testing noise generated by vehicle transmission before delivery is to measure the noise sound pressure level by means of sound level meter. Since the measurement result is susceptible to background noise, the method can only be operated in anechoic chamber. In this paper, in order to measure sound pressure level directly on production-line, a new vibration measurement method and its relevant formula are presented. The proposed method can effectively avoid being affected by background noise and obtain the sound pressure level of transmission noise on production-line by testing the vibration acceleration signals of transmission box. It’s proved that the new method makes the delivery test of transmission noise more convenient and effective. Moreover, it can improve the delivery quality of transmission as well as the performance of whole vehicle.


Sign in / Sign up

Export Citation Format

Share Document