Application of Artificial Neural Networks to Predict Heat Transfer From Buried Pipe for Ground Source Heat Pump Applications

Author(s):  
Hakan Demir ◽  
Ş. Özgür Atayılmaz ◽  
Özden Agra ◽  
Ahmet Selim Dalkılıç

The earth is an energy resource which has more suitable and stable temperatures than air. Ground Source Heat Pumps (GSHPs) were developed to use ground energy for residential heating. The most important part of a GSHP is the Ground Heat Exchanger (GHE) that consists of pipes buried in the soil and is used for transferring heat between the soil and the heat exchanger of the GSHP. Soil composition, density, moisture and burial depth of pipes affect the size of a GHE. Design of GSHP systems in different regions of US and Europe is performed using data from an experimental model. However, there are many more techniques including some complex calculations for sizing GHEs. An experimental study was carried out to investigate heat transfer in soil. A three-layer network is used for predicting heat transfer from a buried pipe. Measured fluid inlet temperatures were used in the artificial neural network model and the fluid outlet temperatures were obtained. The number of the neurons in the hidden layer was determined by a trial and error process together with cross-validation of the experimental data taken from literature evaluating the performance of the network and standard sensitivity analysis. Also, the results of the trained network were compared with the numerical study.

Energies ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 5471
Author(s):  
Peng Li ◽  
Peng Guan ◽  
Jun Zheng ◽  
Bin Dou ◽  
Hong Tian ◽  
...  

Ground thermal properties are the design basis of ground source heat pumps (GSHP). However, effective ground thermal properties cannot be obtained through the traditional thermal response test (TRT) method when it is used in the coaxial borehole heat exchanger (CBHE). In this paper, an improved TRT (ITRT) method for CBHE is proposed, and the field ITRT, based on the actual project, is carried out. The high accuracy of the new method is verified by laboratory experiments. Based on the results of the ITRT and laboratory experiment, the 3D numerical model for CBHE is established, in which the flow directions, sensitivity analysis of heat transfer characteristics, and optimization of circulation flow rate are studied, respectively. The results show that CBHE should adopt the anulus-in direction under the cooling condition, and the center-in direction under the heating condition. The influence of inlet temperature and flow rate on heat transfer rate is more significant than that of the backfill grout material, thermal conductivity of the inner pipe, and borehole depth. The circulating flow rate of CBHE between 0.3 m/s and 0.4 m/s can lead to better performance for the system.


2013 ◽  
Vol 700 ◽  
pp. 231-234
Author(s):  
Lian Yang ◽  
Yong Hong Huang ◽  
Liu Zhang

There are many ground source heat pumps in engineering construction application. However, Research on heat exchanger models of single-hole buried vertical ground source heat pump mostly focuses on single U-tube ground heat exchangers other than double U-tube ones in China currently. Compared with single U-tubes, double U-tubes have the heat transfer particularity of asymmetry. Therefore, the use of the traditional single tube models would have large error in the simulation of the actual double U-tube heat exchangers. This paper frames a three-dimensional heat transfer model for the vertical single-hole buried double u-tube heat exchanger in a ground source heat pump system. The model considers the performance of U-bube material and uses a dual coordinate system and makes the control elemental volumes superimposed.


2014 ◽  
Vol 508 ◽  
pp. 141-145
Author(s):  
Xian Fang Hu ◽  
Yu Yun Li ◽  
Yan Hua Chen ◽  
Zhong Yi Yu

Through the three-dimensional heat transfer simulation of different periodic running of 3×3 tube group during one running period, the article draw the influence of vertical buried tube heat exchanger heat transfer performance under the different start-stop times, when total time is certain, shortening the continuous time of intermittent operation (increasing the start and stop times) helps promote the unit energy efficiency as the outlet water temperature change of the heat exchanger is toward to the favorable direction, and the trend of the change showed first increased and then decreased with the increase of start-stop times. Increasing the number of start and stop times do more contribution to promote the energy efficiency of the heat pump unit under the Working condition of refrigeration.


2021 ◽  
Vol 289 ◽  
pp. 02006
Author(s):  
Elizaveta Tyabut ◽  
Ivan Sokolov ◽  
Artem Ryzhenkov

Geothermal energy is a renewable energy resource. Nowadays it can be considered as a promising alternative to various fossil fuels. Ground source heat pumps are efficient installations enabling the intensive use of underground energy for heating and cooling of modern residential and commercial buildings. However, climatic conditions often limit the use of this type of installation to a certain extent. This paper presents a description of an existing system comprising a liquid-toliquid heat pump and a geothermal field consisting of 4 boreholes. The system is used to investigate the intensity of ground temperature potential decrease in winter and its recovery in summer in the Moscow city environment with a detailed study of the properties of individual soil layers, as well as to study the mutual influence of boreholes on each other, represented by the conditional radius of thermal influence of individual boreholes. Graphs of soil temperature changes at different depths are presented.


Author(s):  
Christopher G. Cvetkovski ◽  
Hoda S. Mozaffari ◽  
Stanley Reitsma ◽  
Tirupati Bolisetti ◽  
David S.-K. Ting

Vertical ground source heat pumps operate by pumping a heat transfer fluid through a pipe buried in the ground. There is a U-Bend at its deepest point to return the fluid to the surface. Incidentally, the U-Bend does more than packing the extensive length of the heat transferring conduit within a single compact borehole. Large flow structures called Dean’s vortices are generated in the bend and these, along with the resulting turbulence produced, are known to significantly enhance the heat transfer processes, and hence, shorten the required length. This study examines the specific roles of Reynolds and Dean numbers on the flow structure and the resulting heat transfer in a pipe with a U-Bend. Water flowing in a pipe without and with heated wall was simulated using FLUENT. The model was verified based on available data in the literature. The efficacy of the local heat transfer rate along the pipe was cast with respect to the subtle changes in the flow characteristics under varying Reynolds number and Dean number.