Critical Heat Flux in Microchannels With an Adjustable Inlet Orifice

Author(s):  
Brent A. Odom ◽  
Carlos A. Ortiz ◽  
Patrick E. Phelan

The benefits of eliminating instabilities in two-phase microchannel flow with inlet orifices come with costs. This study describes the tradeoffs between microchannels with and without inlet orifices, focusing on results from critical heat flux data obtained for various orifice sizes and mass fluxes. An adjustable inlet orifice controlled with a micrometer was placed in front of an array of 31 parallel microchannels each with a hydraulic diameter of 0.235 mm and a length of 1.33 cm. For mass fluxes ranging from 186 kg m−2 s−1 to 847 kg m−2 s−1, critical heat flux (CHF) data were obtained for 7 different orifice sizes. For low flow rates that provided a low quality saturated inlet condition, the difference in CHF values was found to be minimal between open and almost closed orifice conditions. The smallest orifice achieved a CHF value of 5 W cm−2 less than the largest orifice size for a mass flux of 186 kg m−2 s−1, and 7 W cm−2 less for a mass flux of 433 kg m−2 s−1. For mass fluxes higher than 433 kg m−2 s−1, subcooled conditions were present at the orifice inlet, and the highest CHF values occurred with an orifice hydraulic diameter of 35 percent of fully open. For the higher mass flux cases, orifice sizes in the range of 1.8 percent to 28 percent of fully open caused CHF to occur at lower values than less restrictive orifice sizes. This was due to loss of cooling capacity from rapid pressure drop through the orifice. Slightly higher average channel pressures also decrease the refrigerant’s latent heat of vaporization. For the orifice sizes from 35 to 70 percent of unrestricted flow, a very minimal increase in pressure drop over fully open inlet conditions occurred and the general trend was higher CHF values. Very small inlet orifices are beneficial for steady state conditions that do not approach CHF; however, overly restricting the flow at the inlet to microchannels reduces cooling capacity significantly and will cause early onset of CHF. A slightly restrictive inlet orifice will increase CHF.

2013 ◽  
Vol 135 (2) ◽  
Author(s):  
YanFeng Fan ◽  
Ibrahim Hassan

Flow boiling heat transfer in a horizontal microtube with inlet restriction (orifice) under uniform heating condition is experimentally investigated using FC-72 as working fluid. A stainless steel microtube with an inner diameter of 889 μm is selected as main microtube. Two microtubes with smaller diameters are assembled at the inlet of main microtube to achieve the restriction ratios of 50% and 20%. The experimental measurement is carried out at mass fluxes ranging from 160 to 870 kg/m2·s, heat fluxes varying from 6 to 170 kW/m2, inlet temperatures of 23 and 35 °C, and saturation pressures of 10 and 45 kPa. The effects of the orifices on two-phase pressure drop, critical heat flux (CHF), and flow boiling heat transfer coefficient are studied. The results show that the pressure drop caused by the orifice takes a considerable portion in the total pressure drop at low mass fluxes. This ratio decreases as the vapor quality or mass flux increases. The difference of normal critical heat flux in the microtubes with different orifice sizes is negligible. In the aspect of flow boiling heat transfer, the orifice is able to enhance the heat transfer at low mass flux and high saturation pressure, which indicates the contribution of orifice in the nucleate boiling dominated regime. However, the effect of orifice on flow boiling heat transfer is negligible in the forced convective boiling dominated regime.


Author(s):  
Hyun Jin Kim ◽  
Leon Liebenberg ◽  
Anthony M. Jacobi

An experimental investigation was performed to study the heat transfer and pressure drop characteristics of refrigerant R-134a boiling in a chevron-patterned brazed plate heat exchanger (BPHE) at low mass flux. The heat transfer coefficient and pressure drop characteristics are analyzed in relation to varying mass flux (30–50 kgm−2s−1), saturation pressure (675 kPa and 833 kPa), heat flux (0.8 and 2.5 kWm−2), and vapor quality (0.1–0.9). The two-phase pressure drop shows a strong dependence on mass flux and significant saturation temperature drop at high mass flux. The two-phase heat transfer coefficient was both strongly dependent on heat flux (at vapor qualities below 0.4) and on mass flux (at vapor qualities above 0.4). There was also apparent dryout, as depicted by decreased heat transfer at high vapor qualities. These observations suggest that both nucleate and convective boiling mechanisms prevailed. Existing transition correlations however suggest that the experimental data is rather convection-dominant and not a mix of convection and nucleate boiling. The experimental data further strongly suggest the prevalence of both macrochannel and minichannel type flows. Several acknowledged semi-empirical transition criteria were employed to verify our observations. These criteria mostly support our observations that R-134a evaporating at low mass fluxes in a BPHE with a hydraulic diameter of 3.4 mm, has heat transfer and pressure drop characteristics typically indicative of macrochannel as well as minichannel flows. Disagreement however exists with accepted correlations regarding the prevalence of convective or nucleate boiling.


Author(s):  
Anand P. Roday ◽  
Michael K. Jensen

The critical heat flux (CHF) condition sets an upper limit on the flow-boiling heat transfer process. With the growing demand for the use of two-phase flow in micro and nano-sized devices, there is a strong need to understand the CHF phenomenon in channels of such small dimensions. This study experimentally investigates the critical heat flux condition during flow boiling in a single stainless steel microtube of two different diameters—0.427mm, and 0.286 mm. Degassed water is the working fluid. The effects of various parameters—diameter, mass flux (350–1500 kg/m2s), inlet subcooling (2°C–50°C), and length-to-diameter ratio (75–200) on the CHF condition are studied for the exit condition being nearly atmospheric pressure. The CHF increases with an increase in mass flux. The effect of the inlet subcooling on the CHF condition is more complex. With a decreasing inlet subcooling, the CHF decreases until saturated liquid is reached; thereafter, the CHF increases with quality.


Author(s):  
Qian You ◽  
Ibrahim Hassan ◽  
Lyes Kadem

The experiments are conducted to study the flow boiling instability in a single microtube with 0.889 mm hydraulic diameter in vertical upward and downward flow directions (VU and VD). The subcooled dielectric liquid FC-72 is driven at mass fluxes varying from 700 to 1400 kg/m2·s, and the heat flux uniformly applied on the microtube surface is up to 9.6 W/cm2. The onsets of flow oscillations (OFIs) in both flow directions are observed. Their oscillation types and characteristics are presented as well. The effects of mass flux and heat flux on flow instability in vertical flow directions are discussed. The results show that as the mass flux increases, the OFI occurrence is postponed, and the compounded oscillation types (Ledinegg, pressure drop and density wave oscillations) turn to pressure drop type dominant. At low mass fluxes, the OFI appears earlier in VD than in VU due to the buoyancy force impeded the bubble discharging. As the mass flux increases, the OFI appearance in VD is close to the ones in VU and its flow oscillations tend to be re-stabilized. After OFIs appeared at a given mass flux, with more heat flux added, the density wave oscillation type in VU becomes more active. However, at a constant mass flux, as the heat flux increases, the flow instability in VD becomes “stable” which may be due to the rapid flow pattern change, and this kind of “stable” is not expected because the local dryout may accompany. Hence, the microtube with vertical upward flow direction (VU) performs better from flow boiling instability point of view.


1992 ◽  
Vol 114 (1) ◽  
pp. 179-184 ◽  
Author(s):  
K. M. Leroux ◽  
M. K. Jensen

The critical heat flux (CHF) on a single tube in a horizontal bundle subject to an upward crossflow of R113 has been studied in three bundle geometries. Effects of local quality, mass flux, pressure, and bundle geometry on the CHF were investigated. The shapes of the CHF-quality curves display three distinct patterns, which progress from one to another as mass flux increases. At low mass fluxes, the CHF data monotonically decreased with increasing quality. At intermediate mass fluxes with increasing quality, the CHF data initially decreased to a relative minimum, then increased to a relative maximum, and finally began to decrease again as the higher qualities were reached. At high mass fluxes, as quality increased, the CHF rose gradually from the zero quality value to a maximum and then began to decrease. For all mass fluxes, the zero-quality CHF points clustered around an average value, which varied slightly with test section geometry. Mechanisms for the CHF condition are suggested.


2016 ◽  
Vol 366 ◽  
pp. 151-156
Author(s):  
Bei Chen Zhang ◽  
Qing Lian Li ◽  
Yuan Wang ◽  
Jian Qiang Zhang

Two-phase pressure drop fluctuations during flow boiling in a single mini-channel were experimentally investigated. Degassed water was tested in circular cross section mini-channels with the hydraulic diameter of 1.0 mm at liquid mass fluxes range of 21.19-84.77 kg m-2 s-1 and heat fluxes of 0~155.75 kW m-2. Effects of heat flux and mass flux on pressure drop fluctuations were discussed based on the time and frequency domain analysis of the measured pressure drop. Two types of fluctuations were identified, which are the incipient boiling fluctuation (IBF) and the explosive boiling fluctuation (EBF) respectively. The IBF is a low frequency low amplitude fluctuation, which relates to the bubble dynamics when incipient boiling occurs. It is sensitive to the thermal and flow conditions. With the increase of heat flux and mass flux, the IBF is suppressed. The EBF is a low frequency high amplitude fluctuation, which occurs near the critical heat flux.


Author(s):  
Audrius Jasiulevicius ◽  
Rafael Macian-Juan

This paper presents the assessment of TRACE (version v4.160) against the Critical Heat Flux (CHF) experiments in annular tubes performed at the Royal Institute of Technology (KTH) in Stockholm, Sweden. The experimental database includes data for coolant mass fluxes between 250 and 2500 kg/m2s and inlet subcoolings of 10 and 40 K at a pressure of 70 bar. The work presented in this paper supplements the calculations of single round tube experiments carried out earlier and provides a broader scope of validated geometries. In addition to the Biasi and CISE-GE CHF correlations available in the code, a number of experimental points at low flow conditions are available for the annular geometry experiments, which also permitted the assessment of the Biasi/Zuber CHF correlation used in TRACE v4.160 for low flow conditions. Experiments with different axial power distribution were simulated and the effects of the axial power profile and the coolant inlet subcooling on the TRACE predictions were investigated. The results of this work show that the Biasi/Zuber correlation provides good estimation of the CHF at 70 bar, and, for the same conditions, the simulation of the annular experiments resulted in the calculation of lower CHF values compared to single-tube experiments. The analysis of the performance of the standard TRACE CHF correlations shows that the CISE-GE correlation yields critical qualities (quality at CHF) closer to the experimental values at 70 bar than the Biasi correlation for annular flow conditions. Regarding the power profile, the results of the TRACE calculations seem to be very sensitive to its shape, since, depending on the profile, different accuracies in the predictions were noted while other system conditions remained constant. The inlet coolant subcooling was also an important factor in the accuracy of TRACE CHF predictions. Thus, an increase in the inlet subcooling led to a clear improvement in the estimation of the critical quality with both Biasi and CISE-GE correlations. To complement the work, three additional CHF correlations were implemented in TRACE v4.160, namely the Bowring, Tong W-3 and Levitan-Lantsman CHF models, in order to assess the applicability of these correlations to simulate the CHF in annular tubes. The improvement of CHF predictions for low coolant mass flows (up to 1500 kg/m2s) is noted when applying Bowring CHF correlation. However, the increase in the inlet subcooling increases the error in predicted critical quality with the Bowring correlation. The Levitan-Lantsman and Tong-W-3 correlations provide results similar to the Biasi model. Therefore, the most correct CHF predictions among the investigated correlations were obtained using CISE-GE model in the standard TRAC v4.160 code.


Author(s):  
R. Yun ◽  
Y. Kim

Two-phase pressure drops of CO2 are investigated in mini tubes with inner diameters of 2.0 and 0.98 mm and in microchannels with hydraulic diameters from 1.08 to 1.54 mm. For the mini tubes, the tests were conducted with a variation of mass flux from 500 to 3570 kg/m2s, heat flux from 7 to 48 kW/m2, while maintaining saturation temperatures at 0°C, 5°C and 10°C. For the microchannels, mass flux was varied from 100 to 400 kg/m2s, and heat flux was altered from 5 to 20 kW/m2. A direct heating method was used to provide heat into the refrigerants. The pressure drop of CO2 in mini tubes shows very similar trends with that in large diameter tubes. Although the microchannel has a small hydraulic diameter, two-phase effects on frictional pressure drop are significant. The Chisholm parameter of the Lockhart and Martinelli correlation is modified by considering diameter effects on the two-phase frictional multiplier.


Author(s):  
Daxiang Deng ◽  
Qingsong Huang ◽  
Yanlin Xie ◽  
Wei Zhou ◽  
Xiang Huang ◽  
...  

Two-phase boiling in advanced microchannel heat sinks offers an efficient and attractive solution for heat dissipation of high-heat-flux devices. In this study, a type of reentrant copper microchannels was developed for heat sink cooling systems. It consisted of 14 parallel Ω-shaped reentrant copper microchannels with a hydraulic diameter of 781μm. Two-phase pressure drop characteristics were comprehensively accessed via flow boiling tests. Both deionized water and ethanol tests were conducted at inlet subcooling of 10°C and 40°C, mass fluxes of 125–300kg/m2·s, and a wide range of heat fluxes and vapor qualities. The effects of heat flux, mass flux, inlet subcoolings and coolants on the two-phase pressure drop were systematically explored. The results show that the two-phase pressure drop of reentrant copper microchannels generally increased with increasing heat fluxes and vapor qualities. The role of mass flux and inlet temperatures was dependent on the test coolant. The water tests presented smaller pressure drop than the ethanol ones. These results provide critical experimental information for the development of microchannel heat sink cooling systems, and are of considerable practical relevance.


Author(s):  
Tri Dan Le ◽  
Noriaki Inaba ◽  
Minoru Takahashi

Light water reactor could have fast neutron spectrum with high conversion ratio nearly equal unity by using tight lattice fuel assembly with wire spacer. There were some previous about critical heat flux for tight lattice but it were not focused on small range of qualities and also not directly using water as a coolant. We experimentally simulated vertical single fuel rod geometry with and without a wire spacer by using an electrically heated stainless steel rod. The rod is cooled by single or two-phase water in vertical up flow (from the bottom to the top) depending on the electrical input. We determined the critical heat flux for this system by varying the inlet temperature from 333 to 373 K and mass fluxes from 205 to 410 kg/m2s. The result show the critical heat flux (CHF) data in two phase flow condition base on inlet and outlet condition in both case of heater pin with and without wire. The CHF values were higher with wire than without wire due to the effect of wire and spiral flow.