Critical Heat Flux in Horizontal Tube Bundles in Vertical Crossflow of R113

1992 ◽  
Vol 114 (1) ◽  
pp. 179-184 ◽  
Author(s):  
K. M. Leroux ◽  
M. K. Jensen

The critical heat flux (CHF) on a single tube in a horizontal bundle subject to an upward crossflow of R113 has been studied in three bundle geometries. Effects of local quality, mass flux, pressure, and bundle geometry on the CHF were investigated. The shapes of the CHF-quality curves display three distinct patterns, which progress from one to another as mass flux increases. At low mass fluxes, the CHF data monotonically decreased with increasing quality. At intermediate mass fluxes with increasing quality, the CHF data initially decreased to a relative minimum, then increased to a relative maximum, and finally began to decrease again as the higher qualities were reached. At high mass fluxes, as quality increased, the CHF rose gradually from the zero quality value to a maximum and then began to decrease. For all mass fluxes, the zero-quality CHF points clustered around an average value, which varied slightly with test section geometry. Mechanisms for the CHF condition are suggested.

2013 ◽  
Vol 135 (2) ◽  
Author(s):  
YanFeng Fan ◽  
Ibrahim Hassan

Flow boiling heat transfer in a horizontal microtube with inlet restriction (orifice) under uniform heating condition is experimentally investigated using FC-72 as working fluid. A stainless steel microtube with an inner diameter of 889 μm is selected as main microtube. Two microtubes with smaller diameters are assembled at the inlet of main microtube to achieve the restriction ratios of 50% and 20%. The experimental measurement is carried out at mass fluxes ranging from 160 to 870 kg/m2·s, heat fluxes varying from 6 to 170 kW/m2, inlet temperatures of 23 and 35 °C, and saturation pressures of 10 and 45 kPa. The effects of the orifices on two-phase pressure drop, critical heat flux (CHF), and flow boiling heat transfer coefficient are studied. The results show that the pressure drop caused by the orifice takes a considerable portion in the total pressure drop at low mass fluxes. This ratio decreases as the vapor quality or mass flux increases. The difference of normal critical heat flux in the microtubes with different orifice sizes is negligible. In the aspect of flow boiling heat transfer, the orifice is able to enhance the heat transfer at low mass flux and high saturation pressure, which indicates the contribution of orifice in the nucleate boiling dominated regime. However, the effect of orifice on flow boiling heat transfer is negligible in the forced convective boiling dominated regime.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
YanFeng Fan ◽  
Ibrahim Hassan

An experimental study is conducted to investigate the effects of inlet restriction (orifice) on flow boiling instability in a single horizontal microtube. The test-section is composed of a stainless steel tube with an inner diameter of 889 μm, and a length of 150 mm. Experiments are performed for three different orifice configurations with 20%, 35%, and 50% area ratio. Mass flux is varied from 700 to 3000 kg/m2 · s, whereas the heat flux is varied from 6 to 27 W/cm2. The dielectric coolant FC-72 is selected as the working fluid. In the absence of an orifice at the inlet, four oscillation types are observed at the onset of flow instability; it is also noticed that the frequency of the oscillations increases with increasing heat flux, while the amplitude remains constant. The addition of an orifice at the inlet helps stabilizing the flow without generating significant pressure drop at the same operating condition as the microtube without orifice. The 20% area ratio orifice shows better performance at low mass fluxes (<1000 kg/m2 · s). Whereas, at high mass fluxes (>2000 kg/m2 · s), 50% and 35% area ratio orifices are efficient in stabilizing the flow or delaying the onset of flow instability. Therefore, selecting the area ratio of the orifice depends on the operating condition. A small area ratio orifice is preferably used at low mass fluxes, whereas a large area ratio orifice is more suitable for high mass fluxes.


Author(s):  
Brent A. Odom ◽  
Carlos A. Ortiz ◽  
Patrick E. Phelan

The benefits of eliminating instabilities in two-phase microchannel flow with inlet orifices come with costs. This study describes the tradeoffs between microchannels with and without inlet orifices, focusing on results from critical heat flux data obtained for various orifice sizes and mass fluxes. An adjustable inlet orifice controlled with a micrometer was placed in front of an array of 31 parallel microchannels each with a hydraulic diameter of 0.235 mm and a length of 1.33 cm. For mass fluxes ranging from 186 kg m−2 s−1 to 847 kg m−2 s−1, critical heat flux (CHF) data were obtained for 7 different orifice sizes. For low flow rates that provided a low quality saturated inlet condition, the difference in CHF values was found to be minimal between open and almost closed orifice conditions. The smallest orifice achieved a CHF value of 5 W cm−2 less than the largest orifice size for a mass flux of 186 kg m−2 s−1, and 7 W cm−2 less for a mass flux of 433 kg m−2 s−1. For mass fluxes higher than 433 kg m−2 s−1, subcooled conditions were present at the orifice inlet, and the highest CHF values occurred with an orifice hydraulic diameter of 35 percent of fully open. For the higher mass flux cases, orifice sizes in the range of 1.8 percent to 28 percent of fully open caused CHF to occur at lower values than less restrictive orifice sizes. This was due to loss of cooling capacity from rapid pressure drop through the orifice. Slightly higher average channel pressures also decrease the refrigerant’s latent heat of vaporization. For the orifice sizes from 35 to 70 percent of unrestricted flow, a very minimal increase in pressure drop over fully open inlet conditions occurred and the general trend was higher CHF values. Very small inlet orifices are beneficial for steady state conditions that do not approach CHF; however, overly restricting the flow at the inlet to microchannels reduces cooling capacity significantly and will cause early onset of CHF. A slightly restrictive inlet orifice will increase CHF.


2005 ◽  
Vol 35 (1) ◽  
pp. 47-60 ◽  
Author(s):  
Hisashi Umekawa ◽  
Tetsuo Kitajima ◽  
Mio Hirayama ◽  
Mamoru Ozawa ◽  
Kaichiro Mishima ◽  
...  

Author(s):  
Mehmed Rafet Özdemir ◽  
Alihan Kaya ◽  
Ali Koşar

In this article, an experimental study on boiling heat transfer and fluid flow in microtubes at high mass fluxes is presented. De-ionized water flow was investigated over a broad range of mass flux (1000 kg/m2s–7500 kg/m2s) in microtubes with inner diameters of  ∼ 250 μm and ∼685 μm. The reason for using two different capillary diameters was to investigate the size effect on flow boiling. De-ionized water was used as working fluid, and the test section was heated by Joule heating. Heat transfer coefficients and qualities were deduced from local temperature measurements. It was found that high heat removal rates could be achieved at high flow rates under subcooled boiling conditions. It was also observed that heat transfer coefficients increased with mass flux, whereas they decreased with local quality and heat flux. Moreover, experimental heat flux data were compared with partial boiling correlations and fully developed boiling correlations. It was observed that at low wall superheat values, there was only a small inconsistency between the experimental data and the conventional partial boiling prediction method of Bergles, while the subcooled and low quality fully developed boiling heat transfer correlation of Kandlikar could fairly predict experimental results at high wall superheat values.


2013 ◽  
Vol 65 ◽  
pp. 70-78 ◽  
Author(s):  
Alihan Kaya ◽  
Mehmed Rafet Özdemir ◽  
Ali Koşar