Heat Transfer by Mixed Convection Opposing Laminar Flow From the Inside Surface of Uniformly Heated Inclined Circular Tube

Author(s):  
H. Mohammed ◽  
T. Yusaf

This paper aims to investigate the effect of the flow pattern on the mixed convection heat transfer. A 28 thermocouples wire were installed along a 900mm copper tube to measure the temperature distribution. Three insulation layers of fiber glass, asbestos and gypsum were used to minimize to heat lost to the surrounding. A forced convection at the entrance region of a fully developed opposing laminar air flow was investigated to evaluate the flow direction effect on the Nusselt number. The investigation covered a wide range of Reynolds number from 410 to 1600 and heat flux varied from 63W/m2 to 1260W/m2, with different angles of tube inclination of 30°, 45°, 60°, and 90°. It was found that the surface temperature variation along the tube for opposed flow higher than the assisted flow but lower than the horizontal orientation. The Reynolds number has a significant effect on Nusselt number in opposed flow while the effect of Reynolds number was found to be small in the case of assisted flow. The Nusselt number values were lower for opposed flow than the assisted flow. The temperature profiles results have revealed that the secondary flows created by natural convection have a significant effect on the heat transfer process. The obtained average Nusselt number values were correlated by dimensionless groups as Log Nu against Log Ra/Re.

2021 ◽  
Vol 6 (2) ◽  
pp. 41-52
Author(s):  
Mohd Rahimie Md Noor ◽  
Nur Syafiqah Hidayah Mohd Fauzi ◽  
Siti Nur Fadhilah Masrom ◽  
Mohd Azry Abdul Malek ◽  
Muhammad Firdaus Mustapha ◽  
...  

Heat exchangers are tools used to transfer thermal energy between two fluids (liquid or gas) by convection and conduction at different level of temperatures. Heat exchangers are the common equipment and employed in many different applications because of ability to withstand high temperatures and compactness. There are no intermixing or leakage occurred between two fluids during the heat transfer process as fluids are separated by walls of heat exchanger. The main objective of this project is to determine the heat exchanger effectiveness in heat transfer performance. This will be done by investigating the performance of five different angles of heat exchanger which are 150,300, 450, 600 and 750. The effectiveness of heat exchanger depends on the convection heat transfer coefficient of the fluid. Besides that, this project also aims to develop some parameters such as Nusselt number, Reynolds number and Prandtl number for evaluating the heat transfer. It is found that the Nusselt Number at angle of 150 is lower compared to angle of 750. Meanwhile, Reynolds number for angle 150 is higher than angle 750 which means that the type of flow produced by angle 150 is turbulent flow while for 750 angle is laminar flow. Hence, the overall result of this project proved that 150 is the best angle for heat exchanger in chimney because of higher velocity, higher volume flow rate, higher density of gas and higher LMTD. The relationship between Nusselt number and Reynolds number between different angles can be observed by plotting the graph using Maple Software.


Author(s):  
Amr M. Hassaan ◽  
Hesham Mohamad Mostafa

Abstract An experimental study is done to study the convection heat transfer from the outer surface of a group of helical coils that have the same external surface area which is (0.1 m2). These coils are wrapped to form different helical coils with different geometrical dimensions. Five pipe diameters are used in this study also; the pipes are wrapped by different values of coil diameter ranges from 75- 300 mm. The effect of the coil pitch on the heat transfer process has been studied, to reach the value that gives the best performance for each coil. The heat source is steam flowing inside the coil. These coils are tested at different air speeds inside the wind tunnel, which made the Reynolds number (Re) changes from 239 - 3990. The obtained results showed that the Nusselt number enhances with the increase of D/do and P/do to reach the maximum value at the optimum values of D/do and P/do then the Nusselt number begins to decrease. Nusselt number increases with the increase of Reynolds number under all conditions. A correlation for Nusselt number as a function of Reynolds number and the other studied operating parameters reported. By comparing this work with literature, one can find an acceptable agreement in the results.


2012 ◽  
Vol 135 (1) ◽  
Author(s):  
C. Neil Jordan ◽  
Lesley M. Wright

An alternative to ribs for internal heat transfer enhancement of gas turbine airfoils is dimpled depressions. Relative to ribs, dimples incur a reduced pressure drop, which can increase the overall thermal performance of the channel. This experimental investigation measures detailed Nusselt number ratio distributions obtained from an array of V-shaped dimples (δ/D = 0.30). Although the V-shaped dimple array is derived from a traditional hemispherical dimple array, the V-shaped dimples are arranged in an in-line pattern. The resulting spacing of the V-shaped dimples is 3.2D in both the streamwise and spanwise directions. A single wide wall of a rectangular channel (AR = 3:1) is lined with V-shaped dimples. The channel Reynolds number ranges from 10,000–40,000. Detailed Nusselt number ratios are obtained using both a transient liquid crystal technique and a newly developed transient temperature sensitive paint (TSP) technique. Therefore, the TSP technique is not only validated against a baseline geometry (smooth channel), but it is also validated against a more established technique. Measurements indicate that the proposed V-shaped dimple design is a promising alternative to traditional ribs or hemispherical dimples. At lower Reynolds numbers, the V-shaped dimples display heat transfer and friction behavior similar to traditional dimples. However, as the Reynolds number increases to 30,000 and 40,000, secondary flows developed in the V-shaped concavities further enhance the heat transfer from the dimpled surface (similar to angled and V-shaped rib induced secondary flows). This additional enhancement is obtained with only a marginal increase in the pressure drop. Therefore, as the Reynolds number within the channel increases, the thermal performance also increases. While this trend has been confirmed with both the transient TSP and liquid crystal techniques, TSP is shown to have limited capabilities when acquiring highly resolved detailed heat transfer coefficient distributions.


2018 ◽  
Vol 141 (1) ◽  
Author(s):  
M. Mohammadpour-Ghadikolaie ◽  
M. Saffar-Avval ◽  
Z. Mansoori ◽  
N. Alvandifar ◽  
N. Rahmati

Laminar forced convection heat transfer from a constant temperature tube wrapped fully or partially by a metal porous layer and subjected to a uniform air cross-flow is studied numerically. The main aim of this study is to consider the thermal performance of some innovative arrangements in which only certain parts of the tube are covered by metal foam. The combination of Navier–Stokes and Darcy–Brinkman–Forchheimer equations is applied to evaluate the flow field. Governing equations are solved using the finite volume SIMPLEC algorithm and the effects of key parameters such as Reynolds number, metal foam thermophysical properties, and porous layer thickness on the Nusselt number are investigated. The results show that using a tube which is fully wrapped by an external porous layer with high thermal conductivity, high Darcy number, and low drag coefficient, can provide a high heat transfer rate in the high Reynolds number laminar flow, increasing the Nusselt number almost as high as 16 times compared to a bare tube. The most important result of thisstudy is that by using some novel arrangements in which the tube is partially covered by the foam layer, the heat transfer rate can be increased at least 20% in comparison to the fully wrapped tube, while the weight and material usage can be considerably reduced.


2021 ◽  
Vol 321 ◽  
pp. 04014
Author(s):  
Hussein Togun

In this paper, 3D Simulation of turbulent Fe3O4/Nanofluid annular flow and heat transfer in sudden expansion are presented. k-ε turbulence standard model and FVM are applied with Reynolds number different from 20000 to 50000, enlargement ratio (ER) varied 1.25, 1.67, and 2, , and volume concentration of Fe3O4/Nanofluid ranging from 0 to 2% at constant heat flux of 4000 W/m2. The main significant effect on surface Nusselt number found by increases in volume concentration of Fe3O4/Nanofluid for all cases because of nanoparticles heat transport in normal fluid as produced increases in convection heat transfer. Also the results showed that suddenly increment in Nusselt number happened after the abrupt enlargement and reach to maximum value then reduction to the exit passage flow due to recirculation flow as created. Moreover the size of recirculation region enlarged with the rise in enlargement ratio and Reynolds number. Increase of volume Fe3O4/nanofluid enhances the Nusselt number due to nanoparticles heat transport in base fluid which raises the convection heat transfer. Increase of Reynolds number was observed with increased Nusselt number and maximum thermal performance was found with enlargement ratio of (ER=2) and 2% of volume concentration of Fe3O4/nanofluid. Further increases in Reynolds number and enlargement ratio found lead to reductions in static pressure.


2021 ◽  
Author(s):  
Hasib Ahmed Prince ◽  
Didarul Ahasan Redwan ◽  
Enamul Hasan Rozin ◽  
Sudipta Saha ◽  
Mohammad Arif Hasan Mamun

Abstract In this study, a numerical investigation on mixed convection inside a trapezoidal cavity with a pair of rotating cylinders has been conducted. Three different power-law fluid indexes (n = 1.4, 1.0, and 0.6) have been considered to model different sets of non-Newtonian fluids. Four separate cases are considered dependent on the rotation orientation of the cylinders within the cavity. In the first two cases, the cylinders rotate in the same direction, i.e., both counter-clockwise (CCW), and both clockwise (CW), whereas, in the other two cases, cylinders rotate in opposite directions (CW-CCW and CCW-CW). Simulations have been carried out over a broad range of Reynolds number (from 0.5 to 500) and angular speeds (a dimensionless value from 0 to 10). The average Nusselt number values at the isothermal hot inclined cavity surface are determined to evaluate heat transfer performance in various circumstances. Streamlines and isotherm contours are also plotted for better understandings of the effects of different cases for various parameters on thermal and fluid flow fields. It is found that the Nusselt number varies non-linearly with different angular speeds of the cylinders. The combined effect of the mixing induced by cylinder rotation and viscosity characteristics of the fluid dictates the heat transfer in the system. Predictions from the numerical investigation provide insights onto the sets of key parametric configuration that have dominant influence on the thermal performance of lid driven cavity with double rotating cylinders.


2013 ◽  
Vol 2013 ◽  
pp. 1-12 ◽  
Author(s):  
Adnan M. Hussein ◽  
K. V. Sharma ◽  
R. A. Bakar ◽  
K. Kadirgama

The additives of solid nanoparticles to liquids are significant enhancement of heat transfer and hydrodynamic flow. In this study, the thermal properties of three types of nanoparticles (Al2O3, TiO2, and SiO2) dispersed in water as a base fluid were measured experimentally. Forced convection heat transfer turbulent flow inside heated flat tube was numerically simulated. The heat flux around flat tube is 5000 W/m2and Reynolds number is in the range of5×103to50×103. CFD model by finite volume method used commercial software to find hydrodynamic and heat transfer coefficient. Simulation study concluded that the thermal properties measured and Reynolds number as input and friction factor and Nusselt number as output parameters. Data measured showed that thermal conductivity and viscosity increase with increasing the volume concentration of nanofluids with maximum deviation 19% and 6%, respectively. Simulation results concluded that the friction factor and Nusselt number increase with increasing the volume concentration. On the other hand, the flat tube enhances heat transfer and decreases pressure drop by 6% and −4%, respectively, as compared with circular tube. Comparison of numerical analysis with experimental data available showed good agreement with deviation not more than 2%.


2019 ◽  
Vol 141 (7) ◽  
Author(s):  
Andrew F Chen ◽  
Chao-Cheng Shiau ◽  
Je-Chin Han ◽  
Robert Krewinkel

The present study features a two-pass rectangular channel with an aspect ratio (AR) = 4:1 in the first pass and an AR = 2:1 in the second pass after a 180-deg tip turn. In addition to the smooth-wall case, ribs with a profiled cross section are placed at 60 deg to the flow direction on both the leading and trailing surfaces in both passages (P/e = 10, e/Dh ∼ 0.11, parallel and in-line). Regionally averaged heat transfer measurement method was used to obtain the heat transfer coefficients on all internal surfaces. The Reynolds number (Re) ranges from 10,000 to 70,000 in the first passage, and the rotational speed ranges from 0 to 400 rpm. Under pressurized condition (570 kPa), the highest rotation number achieved was Ro = 0.39 in the first passage and 0.16 in the second passage. The results showed that the turn-induced secondary flows are reduced in an accelerating flow. The effects of rotation on heat transfer are generally weakened in the ribbed case than the smooth case. Significant heat transfer reduction (∼30%) on the tip wall was seen in both the smooth and ribbed cases under rotating condition. Overall pressure penalty was reduced for the ribbed case under rotation. Reynolds number effect was found noticeable in the current study. The heat transfer and pressure drop characteristics are sensitive to the geometrical design of the channel and should be taken into account in the design process.


2021 ◽  
Vol 287 ◽  
pp. 03010
Author(s):  
Rajashekhar Pendyala ◽  
Suhaib Umer Ilyas ◽  
Yean Sang Wong

The heat transfer process takes place in numerous applications through the natural convection of fluids. Investigations of the natural convection heat transfer in enclosures have gained vital importance in the last decade for the improvement in thermal performance and design of the heating/cooling systems. Aspect ratios (AR=height/length) of the enclosures are one of the crucial factors during the natural convection heat transfer process. The investigated fluids consisting of air, water, engine oil, mercury, and glycerine have numerous engineering applications. Heat transfer and fluid flow characteristics are studied in 3-dimensional rectangular enclosures with varying aspect ratios (0.125 to 150) using computational fluid dynamics (CFD) simulations. Studies are carried out using the five different fluids having Prandtl number range 0.01 to 4500 in rectangular enclosures with the hot and cold surface with varying temperature difference 20K to 100K. The Nusselt number and heat transfer coefficients are estimated at all conditions to understand the dependency of ARs on the heat transfer performance of selected fluids. Temperature and velocity profiles are compared to study the flow pattern of different fluids during natural convection. The Nusselt number correlations are developed in terms of aspect ratio and Rayleigh number to signify the natural convection heat transfer performance.


2001 ◽  
Vol 123 (4) ◽  
pp. 810-814 ◽  
Author(s):  
Wei-Mon Yan ◽  
Pei-Yuan Tzeng

A numerical calculation has been carried out to investigate the mixed convection heat transfer in inclined rectangular ducts with wall transpiration. The vorticity-velocity method is employed to solve the governing equations. The present paper particularly addresses the effects of the independent parameters, namely, mixed convection parameter Δ, modified Rayleigh number Ra*, wall Reynolds number Rew and aspect ratio γ. The predicted results show that either wall injection or wall suction has a considerable impact on the flow structure and heat transfer performance. Additionally, it was found that for injection case Rew<0, the Nusselt number Nu is retarded with an increase in the wall Reynolds number Rew, but the trend is reverse for the suction flow Rew>0.


Sign in / Sign up

Export Citation Format

Share Document