Effects of Inlet Swirl on Pressure Side Film Cooling of Neighboring Vane Surface

Author(s):  
Yang Zhang ◽  
Yifei Li ◽  
Xiutao Bian ◽  
Xin Yuan

The lean combustion chamber of low NOx emission engines has a short distance between combustion outlet and nozzle guide vanes (NGVs), with strong swirlers located upstream of the turbine inlet to from steady circulation in the combustion region. Although the lean combustion design benefits emission control, it complicates the turbine’s aerodynamics and heat transfer. The strong swirling flow will influence the near-wall flow field where film cooling acts. This research investigates the influence of inlet swirl on the film cooling of cascades. The test cascades are a 1.95 scale model based on the GE-E3 profile, with an inlet Mach number of 0.1 and Reynolds number of 1.48 × 105. Film cooling effectiveness is measured with pressure-sensitive paint (PSP) technology, with nitrogen simulating coolant at a density ratio of near to 1.0. Two neighboring passages are investigated simultaneously, so that pressure and suction side the film cooling effectiveness can be compared. The inlet swirl is produced by a swirler placed upstream, near the inlet, with five positions along the pitchwise direction. These are as follows: blade 1 aligned, passage 1–2 aligned, blade 2 aligned, passage 2–3 aligned and blade 3 aligned. According to the experimental results, the near-hub region is strongly influenced by inlet swirl, where the averaged film cooling effectiveness can differ by up to 12% between the neighboring blades. At the spanwise location Z/Span = 0.7, when the inlet swirl is moved from blade 1 aligned (position 5) to blade 2 aligned (position 3), the film cooling effectiveness in a small area near the endwall can change by up to 100%.

Author(s):  
Yang Zhang ◽  
Yifei Li ◽  
Xin Yuan

Though the temperature of the coolant injected from the endwall increases after the mixing process in the main flow, the injections moving from the endwall to the airfoil suction side still have the potential of second order cooling. This part of the coolant is called “Phantom cooling” in the paper. This paper is focused on the function of the coolant from fan-shaped holes on endwall surface which brought by passage vortex to the airfoil suction side. The test cascades are based on the profile of General Electric Energy Efficient Engine (GE-E3), with the inlet Mach number of 0.1 and Reynolds number of 1.46×105. The scale ratio of the test vanes is 1.95 and the film cooling effectiveness is tested with Pressure Sensitive Painting (PSP) Technology. Nitrogen is used to simulate the coolant which can provide a density ratio near 1.0. Two adjacent passages are investigated simultaneously by which the film cooling effectiveness can be compared in the same case on the suction side surface. The inlet rotating flow is simulated by an upstream swirler at the inlet, fixed at 5 different positions along the pitchwise direction. They are Blade 0 aligned, Passage 1 aligned, Blade 1 aligned, Passage 2 aligned and Blade 2 aligned. According to the experimental results, the inlet rotating flow can dominate the film cooling effectiveness distribution at the Suction Side. The averaged film cooling effectiveness changes substantially with the change in the swirler position. The inlet swirling flow effects are compared on the adjacent vanes at upstream and downstream regions. The research shows that the different pitchwise position of the inlet swirler is a significant factor which can change the phantom cooling phenomenon on the suction side. The relative position of inlet swirler cannot be ignored for Nozzle Guide Vane design.


Author(s):  
Shang-Feng Yang ◽  
Je-Chin Han ◽  
Alexander MirzaMoghadam ◽  
Ardeshir Riahi

This paper studies the effect of transonic flow velocity on local film cooling effectiveness distribution of turbine vane suction side, experimentally. A conduction-free Pressure Sensitive Paint (PSP) method is used to determine the local film cooling effectiveness. Tests were performed in a five-vane annular cascade at Texas A&M Turbomachinery laboratory blow-down flow loop facility. The exit Mach numbers are controlled to be 0.7, 0.9, and 1.1, from subsonic to transonic flow conditions. Three foreign gases N2, CO2 and Argon/SF6 mixture are selected to study the effects of three coolant-to-mainstream density ratios, 1.0, 1.5, and 2.0 on film cooling. Four averaged coolant blowing ratios in the range, 0.7, 1.0, 1.3 and 1.6 are investigated. The test vane features 3 rows of radial-angle cylindrical holes around the leading edge, and 2 rows of compound-angle shaped holes on the suction side. Results suggest that the PSP technique is capable of producing clear and detailed film cooling effectiveness contours at transonic condition. The effects of coolant to mainstream blowing ratio, density ratio, and exit Mach number on the vane suction-surface film cooling distribution are obtained, and the consequence results are presented and explained in this investigation.


Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke wheel wake generator) on the modeled rotor blade is studied using the Pressure Sensitive Paint (PSP) mass transfer analogy method. Emphasis of the current study is on the mid-span region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film cooling holes. The blade also has radial shower-head leading edge film cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds Number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side; 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


2006 ◽  
Vol 129 (2) ◽  
pp. 294-302 ◽  
Author(s):  
Scot K. Waye ◽  
David G. Bogard

Adiabatic film cooling effectiveness of axial holes embedded within a transverse trench on the suction side of a turbine vane was investigated. High-resolution two-dimensional data obtained from infrared thermography and corrected for local conduction provided spatial adiabatic effectiveness data. Flow parameters of blowing ratio, density ratio, and turbulence intensity were independently varied. In addition to a baseline geometry, nine trench configurations were tested, all with a depth of 1∕2 hole diameter, with varying widths, and with perpendicular and inclined trench walls. A perpendicular trench wall at the very downstream edge of the coolant hole was found to be the key trench characteristic that yielded much improved adiabatic effectiveness performance. This configuration increased adiabatic effectiveness up to 100% near the hole and 40% downstream. All other trench configurations had little effect on the adiabatic effectiveness. Thermal field measurements confirmed that the improved adiabatic effectiveness that occurred for a narrow trench with perpendicular walls was due to a lateral spreading of the coolant and reduced coolant jet separation. The cooling levels exhibited by these particular geometries are comparable to shaped holes, but much easier and cheaper to manufacture.


2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Shiou-Jiuan Li ◽  
Je-Chin Han

The effect of an unsteady stator wake (simulated by wake rods mounted on a spoke-wheel wake generator) on the modeled rotor blade is studied using the pressure sensitive paint (PSP) mass-transfer analogy method. Emphasis of the current study is on the midspan region of the blade. The flow is in the low Mach number (incompressible) regime. The suction (convex) side has simple angled cylindrical film-cooling holes; the pressure (concave) side has compound angled cylindrical film-cooling holes. The blade also has radial shower-head leading edge film-cooling holes. Strouhal numbers studied range from 0 to 0.36; the exit Reynolds number based on the axial chord is 530,000. Blowing ratios range from 0.5 to 2.0 on the suction side and 0.5 to 4.0 on the pressure side. Density ratios studied range from 1.0 to 2.5, to simulate actual engine conditions. The convex suction surface experiences film-cooling jet lift-off at higher blowing ratios, resulting in low effectiveness values. The film coolant is found to reattach downstream on the concave pressure surface, increasing effectiveness at higher blowing ratios. Results show deterioration in film-cooling effectiveness due to increased local turbulence caused by the unsteady wake, especially on the suction side. Results also show a monotonic increase in film-cooling effectiveness on increasing the coolant to mainstream density ratio.


Author(s):  
Kevin Liu ◽  
Shang-Feng Yang ◽  
Je-Chin Han

Adiabatic film-cooling effectiveness is examined systematically on a typical high pressure turbine blade by varying three critical flow parameters: coolant blowing ratio, coolant-to-mainstream density ratio, and freestream turbulence intensity. Three average coolant blowing ratios 1.0, 1.5, and 2.0; three coolant density ratios 1.0, 1.5, and 2.0; two turbulence intensities 4.2% and 10.5%, are chosen for this study. Conduction-free pressure sensitive paint (PSP) technique is used to measure film-cooling effectiveness. Three foreign gases — N2 for low density, CO2 for medium density, and a mixture of SF6 and Argon for high density are selected to study the effect of coolant density. The test blade features 45° compound-angle shaped holes on the suction side and pressure side, and 3 rows of 30° radial-angle cylindrical holes around the leading edge region. The inlet and the exit Mach number are 0.27 and 0.44, respectively. Reynolds number based on the exit velocity and blade axial chord length is 750,000. Results reveal that the PSP is a powerful technique capable of producing clear and detailed film effectiveness contours with diverse foreign gases. As blowing ratio exceeds the optimum value, it induces more mixing of coolant and mainstream. Thus film-cooling effectiveness reduces. Greater coolant-to-mainstream density ratio results in lower coolant-to-mainstream momentum and prevents coolant to lift-off; as a result, film-cooling increases. Higher freestream turbulence causes effectiveness to drop everywhere except in the region downstream of suction side. Results are also correlated with momentum flux ratio and compared with previous studies. It shows that compound shaped hole has the greatest optimum momentum flux ratio, and then followed by axial shaped hole, compound cylindrical hole, and axial cylindrical hole.


Author(s):  
Scot K. Waye ◽  
David G. Bogard

Film cooling adiabatic effectiveness for axial and compound angle holes on the suction side of a simulated turbine vane was investigated to determine the relative performance of these configurations. The effect of the surface curvature was also evaluated by comparing to previous curvature studies and flat plate film cooling results. Experiments were conducted for varying coolant density ratio, mainstream turbulence levels, and hole spacing. Results from these measurements showed that for mild curvature, 2r/d ≈ 160, flat plate results are sufficient to predict the cooling effectiveness. Furthermore, the compound angle injection improves adiabatic effectiveness for higher blowing ratios, similar to previous studies using flat plate facilities.


2014 ◽  
Vol 521 ◽  
pp. 104-107
Author(s):  
Ling Zhang ◽  
Quan Heng Jin ◽  
Da Fei Guo

The Realizable k-ε turbulence model was performed to investigate the film cooling effectiveness with different blowing ratio 1,1.5,2 and different density ratio 1,1.5,2.The results show that, cooling effectiveness increases with the augment of blowing ratio. On the pressure side, cooling effectiveness increases with the augment of density ratio. On the suction side, with higher density ratio the leading edge cooling increases, the middle section reduces, and the trailing edge cooling effectiveness increases first decreases.


2006 ◽  
Vol 129 (2) ◽  
pp. 202-211 ◽  
Author(s):  
Scot K. Waye ◽  
David G. Bogard

Film cooling adiabatic effectiveness for axial and compound angle holes on the suction side of a simulated turbine vane was investigated to determine the relative performance of these configurations. The effect of the surface curvature was also evaluated by comparing to previous curvature studies and flat plate film cooling results. Experiments were conducted for varying coolant density ratio, mainstream turbulence levels, and hole spacing. Results from these measurements showed that for mild curvature, 2r∕d≈160, flat plate results are sufficient to predict the cooling effectiveness. Furthermore, the compound angle injection improves adiabatic effectiveness for higher blowing ratios, similar to previous studies using flat plate facilities.


Author(s):  
U. Drost ◽  
A. Bölcs

In the present study film cooling effectiveness and heat transfer were systematically investigated on a turbine NGV airfoil employing the transient liquid crystal technique and a multiple regression procedure. Tests were conducted in a linear cascade at exit Reynolds numbers of 0.52e6, 1.02e6 and 1.45e6 and exit Mach numbers of 0.33, 0.62 and 0.8, at two mainstream turbulence intensities of 5.5% and 10%. The film cooling geometry consisted of a single compound angle row on the pressure side (PS), and a single or a double row on the suction side (SS). Foreign gas injection was used to obtain a density ratio of approximately 1.65, while air injection yielded a density ratio of unity. Tests were conducted for blowing ratios of 0.25 to 2.3 on the SS, and 0.55 to 7.3 on the PS. In general film cooling injection into a laminar BL showed considerably higher effectiveness in the near hole region, as compared to a turbulent BL. While mainstream turbulence had only a weak influence on SS cooling, higher effectiveness was noted on the PS at high turbulence due to increased lateral spreading of the coolant. Effects of mainstream Mach and Reynolds number were attributed to changes of the BL thickness and flow acceleration. Higher density coolant yielded higher effectiveness on both SS and PS, whereas heat transfer ratios were increased on the SS and decreased on the PS. Comparison of the single and double row cooling configurations on the SS revealed a better film cooling performance of the double row due to an improved film coverage and delayed jet separation.


Sign in / Sign up

Export Citation Format

Share Document