Thermodynamic Optimization of Advanced Steam Power Plants Retrofitted for Oxy-Coal Combustion

Author(s):  
M. V. J. J. Suresh ◽  
K. S. Reddy ◽  
Ajit Kumar Kolar

Thermodynamic optimization of power plants based on supercritical (SupC) and ultrasupercritical (USC) steam parameters is reported in this article. The objective is to compute the maximum attainable power plant efficiency in Indian climatic conditions using high ash (HA) indigenous coal. A unit size of 800 MWe presently under development in India is considered for energy and exergy analysis of power plants. Commercially established steam turbine parameters are used for the optimization of SupC power plant, whereas advanced steam turbine parameters currently under research and development are used for the optimization of USC power plant. The plant energy efficiency of the optimized SupC and USC power plant based on air-coal combustion (ACC) show considerable increases of 2.8 and 5.2% points, respectively compared with the current SupC ACC power plant (reference plant) being commissioned in India. The increases in plant exergy efficiency for the same power plants are 2.6 and 4.8% points and the corresponding CO2 reductions are about 6 and 11%, respectively. The maximum possible plant energy efficiency in Indian climatic conditions using HA Indian coal is about 42.7% (USC power plant). The effect of low ash coal on plant energy and exergy efficiencies compared with HA coal is also presented. Further, the effect of oxy-coal combustion (OCC) on the plant energy and exergy efficiencies compared with the ACC is studied for the double reheat SupC and USC power plants to account for the impact of CO2 capture. A significant reduction of 8.8 and 6.6% points in plant energy efficiency is observed for SupC and USC OCC power plants, respectively compared with the reference SupC ACC power plant.

Author(s):  
Soumya Jyoti Chatterjee ◽  
Goutam Khankari ◽  
Sujit Karmakar

The comparative performance study is carried out for 500 MW Supercritical (SupC) Oxy-Coal Combustion (OCC) and Air-Coal Combustion (ACC) power plants with membrane-based CO2 capture at the fixed furnace temperature. The proposed configurations are modelled using a computer-based analysis software 'Cycle-Tempo' at different operating conditions, and the detailed thermodynamic study is done by considering Energy, Exergy, and Environmental (3-E) analysis. The result shows that the net energy and exergy efficiencies of ACC power plants with CO2 capture are about 35.07 % and 30.88 %, respectively, which are about 6.44 % and 5.77 % points, respectively higher than that of OCC power plant. Auxiliary power consumption of OCC based power plant is almost 1.97 times more than that of the ACC based plant due to huge energy utilization in the Air Separation Unit (ASU) of OCC plant which leads to performance reduction in OCC plant. However, environmental benefit of OCC based power plant is more than that of ACC based power plant with respect to CO2 emission. OCC plant emits about 0.164 kg/kWh of CO2 which is approximately 16.75 times lower than the CO2 emission in ACC based power plant. It is also analyzed that the performance of the CO2 Capture Unit (CCU) for the OCC based plant is about 3.65 times higher than the ACC based power plant due to higher concentration of CO2 (nearly 80.63%) in the flue gas emitting from OCC plant. The study also reveals that the auxiliary power consumption per kg of CO2 capture of the OCC based plant is about 0.142 kWh/kg, which is approximately 0.06 times lower than the ACC based plant. The higher performance of the OCC based power plant is found at lower value of flue gas recirculation due to the fact that reduction in exergy destruction at the mixing zone of the combustor is higher than the increase in exergy destruction of the heat exchangers at higher furnace exit temperature. But the metallurgical temperature limit of boiler tube materials restricts the use of the higher value of furnace temperature. OCC based power plant with CO2 capture can be preferred over ACC based plant with CO2 capture due to higher environmental benefits towards mitigating CO2, the key greenhouse gas on earth in spite of exhibiting lesser energy and exergy efficiencies.


Author(s):  
Vladislav Panchenko ◽  
Ruslan Kharin

An analysis of losses in a solar power plant of direct current № 18 с. Zmiiv, Kharkivregion with all climatic conditions of this region. The energy efficiency indicators of inverters used in these solar power plants are analyzed. According to experimental data based on the softwarepackage PVsyst measured energy losses generated by a solar power plant. Connecting the SES to themains can improve the voltage levels at the system nodes, but it is necessary to provide a powerreserve in the system to cover the power deficit in the event of a sudden shutdown due to naturalfactors.To analyze the energy losses of solar energy, the software package PVsyst was used, whichallows you to analyze the parameters of electricity losses with the display of loss diagrams for theyear and the dependence of the amount of losses in electricity generation by solar panels. PVsystsoftware is used to calculate the output power, performance, and total loss of a station connected tothe network. Losses calculated by PVsyst software include two types: PV array loss and System loss.After analyzing research conducted in Ukraine and other European countries, it is possible toconclude that the impact of poor quality electricity on electrical equipment is quite significant, andthe study of the impact of unconventional generation sources on electricity quality indicators willidentify ways to reduce electricity losses and increase electricity life equipment. The efficiency ofsolar energy conversion is greatly reduced due to reflections from the surface of the photovoltaicsystem. Also due to the peculiarities of the construction of photovoltaic converters there is a decreasein the efficiency of solar panels with increasing temperature.


Author(s):  
В. Буланин ◽  
V. Bulanin

The main energy-consuming element of the heat supply system of cities and settlements is a source of heat energy. In connection with the need to minimize the cost of fuel and electricity for heat supply, the article presents an analysis of the energy balance of the steam turbine installation, on the basis of which new analytical expressions are developed that comprehensively characterize the efficiency of the power plant. In 2000 еру RD 153-34.1-09.163-00 "Model program of energy audits of thermal power plants and district boiler houses of joint-stock companies of power and electrification of Russia" was enacted. Some aspects of the analysis of the energy balance of the steam turbine installation using the relative increase in heat consumption for condensation power generation are considered. An analytical assessment of the impact of energy costs on the boiler unit's own needs on the energy balance of the thermal power plant is made.


2021 ◽  
Vol 13 (13) ◽  
pp. 7279
Author(s):  
Zbigniew Skibko ◽  
Magdalena Tymińska ◽  
Wacław Romaniuk ◽  
Andrzej Borusiewicz

Wind power plants are an increasingly common source of electricity located in rural areas. As a result of the high variability of wind power, and thus the generated power, these sources should be classified as unstable sources. In this paper, the authors attempted to determine the impact of wind turbine operation on the parameters of electricity supplied to farms located near the source. As a result of the conducted field tests, variability courses of the basic parameters describing the supply voltage were obtained. The influence of power plant variability on the values of voltage, frequency, and voltage distortion factor was determined. To estimate the capacity of the transmission lines, the reactive power produced in the power plant and its effect on the value of the power factor were determined. The conducted research and analysis showed that the wind power plant significantly influences voltage fluctuations in its immediate vicinity (the maximum value registered was close to 2%, while the value required by law was 2.5%). Although all the recorded values are within limits specified by the current regulations (e.g., the THD value is four times lower than the required value), wind turbines may cause incorrect operation of loads connected nearby. This applies mainly to cases where consumers sensitive to voltage fluctuations are installed in the direct vicinity of the power plant.


Author(s):  
V. A. Khrustalev ◽  
M. V. Garievskii

The article presents the technique of an estimation of efficiency of use of potential heat output of an auxiliary boiler (AB) to improve electric capacity and manoeuvrability of a steam turbine unit of a power unit of a nuclear power plant (NPP) equipped with a water-cooled water-moderated power reactor (WWER). An analysis of the technical characteristics of the AB of Balakovo NPP (of Saratov oblast) was carried out and hydrocarbon deposits near the NPP were determined. It is shown that in WWER nuclear power plants in Russia, auxiliary boilers are mainly used only until the normal operation after start-up whereas auxiliary boiler equipment is maintained in cold standby mode and does not participate in the generation process at power plants. The results of research aimed to improve the systems of regulation and power management of power units; general principles of increasing the efficiency of production, transmission and distribution of electric energy, as well as the issues of attracting the potential of energy technology sources of industrial enterprises to provide load schedules have been analyzed. The possibility of using the power complex NPP and the AB as a single object of regulation is substantiated. The authors’ priority scheme-parametric developments on the possibility of using the thermal power of the auxiliary boilers to increase the power of the steam turbine of a nuclear power plant unit equipped with WWER reactors unit during peak periods, as well as the enthalpy balance method for calculating heat flows, were applied. The surface area of the additional heater of the regeneration “deaerator – high pressure heaters” system and its cost were calculated. On the basis of calculations, it was shown that the additional power that can be obtained in the steam turbine of the NPP with a capacity of 1200 MW due to the use of heat of the modernized auxiliary boiler in the additional heat exchanger is 40.5 MW. The additional costs for the implementation of the heat recovery scheme of the auxiliary boiler at different prices for gas fuel and the resulting system effect were estimated in an enlarged way. Calculations have shown the acceptability of the payback period of the proposed modernization.


2019 ◽  
Vol 23 (Suppl. 4) ◽  
pp. 1143-1151 ◽  
Author(s):  
Karol Sztekler ◽  
Wojciech Kalawa ◽  
Sebastian Stefanski ◽  
Jaroslaw Krzywanski ◽  
Karolina Grabowska ◽  
...  

At present, energy efficiency is a very important issue and it is power generation facilities, among others, that have to confront this challenge. The simultaneous production of electricity, heat and cooling, the so-called trigeneration, allows for substantial savings in the chemical energy of fuels. More efficient use of the primary energy contained in fuels translates into tangible earnings for power plants while reductions in the amounts of fuel burned, and of non-renewable resources in particular, certainly have a favorable impact on the natural environment. The main aim of the paper was to investigate the contribution of the use of adsorption chillers to improve the energy efficiency of a conventional power plant through the utilization of combined heat and power waste heat, involving the use of adsorption chillers. An adsorption chiller is an item of industrial equipment that is driven by low grade heat and intended to produce chilled water and desalinated water. Nowadays, adsorption chillers exhibit a low coefficient of performance. This type of plant is designed to increase the efficiency of the primary energy use. This objective as well as the conservation of non-renewable energy resources is becoming an increasingly important aspect of the operation of power generation facilities. As part of their project, the authors have modelled the cycle of a conventional heat power plant integrated with an adsorption chiller-based plant. Multi-variant simulation calculations were performed using IPSEpro simulation software.


2021 ◽  
Vol 2083 (2) ◽  
pp. 022020
Author(s):  
Jiahuan Yu ◽  
Xiaofeng Zhang

Abstract With the development of the nuclear energy industry and the increasing demand for environmental protection, the impact of nuclear power plant radiation on the environment has gradually entered the public view. This article combs the nuclear power plant radiation environmental management systems of several countries, takes the domestic and foreign management of radioactive effluent discharge from nuclear power plants as a starting point, analyses and compares the laws and standards related to radioactive effluents from nuclear power plants in France, the United States, China, and South Korea. In this paper, the management improvement of radioactive effluent discharge system of Chinese nuclear power plants has been discussed.


Author(s):  
Sang-Nyung Kim ◽  
Sang-Gyu Lim

The safety injection (SI) nozzle of a 1000MWe-class Korean standard nuclear power plant (KSNP) is fitted with thermal sleeves (T/S) to alleviate thermal fatigue. Thermal sleeves in KSNP #3 & #4 in Yeonggwang (YG) & Ulchin (UC) are manufactured out of In-600 and fitted solidly without any problem, whereas KSNP #5 & #6 in the same nuclear power plants, also fitted with thermal sleeves made of In-690 for increased corrosion resistance, experienced a loosening of thermal sleeves in all reactors except KSNP YG #5-1A, resulting in significant loss of generation availability. An investigation into the cause of the loosening of the thermal sleeves only found out that the thermal sleeves were subject to severe vibration and rotation, failing to uncover the root cause and mechanism of the loosening. In an effort to identify the root cause of T/S loosening, three suspected causes were analyzed: (1) the impact force of flow on the T/S when the safety SI nozzle was in operation, (2) the differences between In-600 and In-690 in terms of physical and chemical properties (notably the thermal expansion coefficient), and (3) the positioning error after explosive expansion of the T/S as well as the asymmetric expansion of T/S. It was confirmed that none of the three suspected causes could be considered as the root cause. However, after reviewing design changes applied to the Palo Verde nuclear plant predating KSNP YG #3 & #4 to KSNP #5 & #6, it was realized that the second design modification (in terms of groove depth & material) had required an additional explosive energy by 150% in aggregate, but the amount of gunpowder and the explosive expansion method were the same as before, resulting in insufficient explosive force that led to poor thermal sleeve expansion. T/S measurement data and rubbing copies also support this conclusion. In addition, it is our judgment that the acceptance criteria applicable to T/S fitting was not strict enough, failing to single out thermal sleeves that were not expanded sufficiently. Furthermore, the T/S loosening was also attributable to lenient quality control before and after fitting the T/S that resulted in significant uncertainty. Lastly, in a flow-induced vibration test planned to account for the flow mechanism that had a direct impact upon the loosening of the thermal sleeves that were not fitted completely, it was discovered that the T/S loosening was attributable to RCS main flow. In addition, it was proven theoretically that the rotation of the T/S was induced by vibration.


Polymers ◽  
2020 ◽  
Vol 12 (8) ◽  
pp. 1828 ◽  
Author(s):  
Izabela Piasecka ◽  
Patrycja Bałdowska-Witos ◽  
Józef Flizikowski ◽  
Katarzyna Piotrowska ◽  
Andrzej Tomporowski

Controlling the system—the environment of power plants is called such a transformation—their material, energy and information inputs in time, which will ensure that the purpose of the operation of this system or the state of the environment, is achieved. The transformations of systems and environmental inputs and their goals describe the different models, e.g., LCA model groups and methods. When converting wind kinetic energy into electricity, wind power plants emit literally no harmful substances into the environment. However, the production and postuse management stages of their components require large amounts of energy and materials. The biggest controlling problem during postuse management is wind power plant blades, followed by waste generated during their production. Therefore, this publication is aimed at carrying out an ecological, technical and energetical transformation analysis of selected postproduction waste of wind power plant blades based on the LCA models and methods. The research object of control was eight different types of postproduction waste (fiberglass mat, roving fabric, resin discs, distribution hoses, spiral hoses with resin, vacuum bag film, infusion materials residues, surplus mater), mainly made of polymer materials, making it difficult for postuse management and dangerous for the environment. Three groups of models and methods were used: Eco-indicator 99, IPCC and CED. The impact of analysis objects on human health, ecosystem quality and resources was controlled and assessed. Of all the tested waste, the life cycle of resin discs made of epoxy resin was characterized by the highest level of harmful technology impact on the environment and the highest energy consumption. Postuse control and management in the form of recycling would reduce the negative impact on the environment of the tested waste (in the perspective of their entire life cycle). Based on the results obtained, guidelines and models for the proecological postuse control of postproduction polymer waste of wind power plants blades were proposed.