Forced-Convection Heat Transfer for Single and Two-Phase Helical Flow in a Solar Receiver

1986 ◽  
Vol 108 (1) ◽  
pp. 76-83 ◽  
Author(s):  
F. N. Vafaie ◽  
J. R. Dunn

The heat transfer characteristics of a single-tube, helically coiled receiver for a concentrating solar collector are presented. Heat transfer coefficients were measured for single and two-phase water-steam flow in a helical coil subjected to radiant heating for a range of flow conditions and radiant flux levels. Results are presented for both the local and average heat transfer coefficients in several flow regimes.

Author(s):  
Haruhiko Ohta ◽  
Koichi Inoue ◽  
Yuichiro Shimada

Flow boiling heat transfer in a single small tube is investigated by using FC72 as a working fluid. The heat transfer coefficients are measured in the ranges of heat flux 2–24kW/m2 and mass velocity 100–400kg/m2s under the condition of near atmospheric pressure. Test tube, made of stainless steel, has an inner diameter of 0.51mm and a heated length of 200mm. The tube is located horizontally in a vacuum chamber to reduce the heat loss and to minimize the time to obtain data regarded as that of steady state. In the single-phase region, heat transfer coefficients due to forced convection are in good agreement with the values from the conventional theories. In the saturated region, measured heat transfer characteristics are quite different depending on whether the test liquid is deaerated or not deaerated before the experiments. By using deaerated liquid, three different heat transfer regimes are observed: In the first regime, the heat transfer is dominated by nucleate boiling in low vapor quality, and the heat transfer is deteriorated or enhanced depending on the channel confinement and heat flux. In the second regime, the heat transfer is dominated by two-phase forced convection in moderate quality as is well known for the tubes of normal size. In the third regime, the heat transfer is dominated again by two-phase forced convection, but is deteriorated in high quality. One or two regimes can disappear or become unclear depending on the conditions of flow and heating. The effects of vapor quality and mass velocity on the heat transfer characteristics due to two-phase forced convection in the moderate vapor quality are clarified in the experimental ranges tested. And a reason for the gradual heat transfer deterioration observed in high quality is discussed based on the liquid-vapor behaviors inherent in small diameter tubes.


2016 ◽  
Vol 138 (1) ◽  
Author(s):  
Hyoungsoon Lee ◽  
Damena D. Agonafer ◽  
Yoonjin Won ◽  
Farzad Houshmand ◽  
Catherine Gorle ◽  
...  

Gallium nitride (GaN) high-electron-mobility transistors (HEMTs) dissipate high power densities which generate hotspots and cause thermomechanical problems. Here, we propose and simulate GaN-based HEMT technologies that can remove power densities exceeding 30 kW/cm2 at relatively low mass flow rate and pressure drop. Thermal performance of the microcooler module is investigated by modeling both single- and two-phase flow conditions. A reduced-order modeling approach, based on an extensive literature review, is used to predict the appropriate range of heat transfer coefficients associated with the flow regimes for the flow conditions. Finite element simulations are performed to investigate the temperature distribution from GaN to parallel microchannels of the microcooler. Single- and two-phase conjugate computational fluid dynamics (CFD) simulations provide a lower bound of the total flow resistance in the microcooler as well as overall thermal resistance from GaN HEMT to working fluid. A parametric study is performed to optimize the thermal performance of the microcooler. The modeling results provide detailed flow conditions for the microcooler in order to investigate the required range of heat transfer coefficients for removal of heat fluxes up to 30 kW/cm2 and a junction temperature maintained below 250 °C. The detailed modeling results include local temperature and velocity fields in the microcooler module, which can help in identifying the approximate locations of the maximum velocity and recirculation regions that are susceptible to dryout conditions.


Author(s):  
G. Qureshi ◽  
M. H. Nguyen ◽  
N. R. Saad ◽  
R. N. Tadros

To optimise the turbine disc weight and coolant flow requirements, the aspect of improving thermal analysis was investigated. As a consequence, an experimental investigation was undertaken to measure the rates of convective heat transfer. The constant temperature steady state technique was used to determine the local and average heat transfer coefficients on the sides of rotating discs. The effects of coolant flow rates, CW (3000 ≤ CW ≤ 18600) with two types of cavity in-flow conditions and of the rotational speeds, Reθ (from 4×105 to 1.86×106) on the disc heat transfer were studied and correlations developed. For a rotating disc in confined cavities with superimposed coolant flows, Nusselt numbers were found to be higher than those for the free rotating disc without confinement.


Author(s):  
Koichi Araga ◽  
Keisuke Okamoto ◽  
Keiji Murata

This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.


Author(s):  
Wenhai Li ◽  
Ken Alabi ◽  
Foluso Ladeinde

Over the years, empirical correlations have been developed for predicting saturated flow boiling [1–15] and condensation [16–30] heat transfer coefficients inside horizontal/vertical tubes or micro-channels. In the present work, we have examined 30 of these models, and modified many of them for use in compact plate-fin heat exchangers. However, the various correlations, which have been developed for pipes and ducts, have been modified in our work to make them applicable to extended fin surfaces. The various correlations have been used in a low-order, one-dimensional, finite-volume type numerical integration of the flow and heat transfer equations in heat exchangers. The NIST’s REFPROP database [31] is used to account for the large variations in the fluid thermo-physical properties during phase change. The numerical results are compared with Yara’s experimental data [32]. The validity of the various boiling and condensation models for a real plate-fin heat exchanger design is discussed. The results show that some of the modified boiling and condensation correlations can provide acceptable prediction of heat transfer coefficient for two-phase flows in compact plate-fin heat exchangers.


1959 ◽  
Vol 81 (1) ◽  
pp. 24-28 ◽  
Author(s):  
Samuel Globe ◽  
David Dropkin

This paper presents results of an experimental investigation of convective heat transfer in liquids placed between two horizontal plates and heated from below. The liquids used were water, silicone oils of 1.5, 50, and 1000 centistoke kinematic viscosities, and mercury. The experiments covered a range of Rayleigh numbers between 1.51(10)5 and 6.76(10)8. and Prandtl numbers between 0.02 and 8750. Tests were made in cylindrical containers having copper tops and bottoms and insulating walls. For water and silicone oils the container was 5 in. in diam and 2 in. high. For mercury, two containers were used, both 5.28 in. in diameter, but one 1.39 in. high and another 2.62 in. high. In all cases the bottom plates were heated by electric heaters. The top plates were air-cooled for the water and silicone-oil experiments and water-cooled for the mercury tests. To prevent amalgamation, the copper plates of the mercury container were chromium plated. Surface temperatures were measured by thermocouples embedded in the plates. The test results indicate that the heat-transfer coefficients for all liquids investigated may be determined from the relationship Nu=0.069Ra13Pr0.074 In this equation the Nusselt and Rayleigh numbers are based on the distance between the copper plates. The results of this experiment are in reasonable agreement with the data reported by others who used larger containers and different fluids.


Sign in / Sign up

Export Citation Format

Share Document