Natural-Convection Heat Transfer in Liquids Confined by Two Horizontal Plates and Heated From Below

1959 ◽  
Vol 81 (1) ◽  
pp. 24-28 ◽  
Author(s):  
Samuel Globe ◽  
David Dropkin

This paper presents results of an experimental investigation of convective heat transfer in liquids placed between two horizontal plates and heated from below. The liquids used were water, silicone oils of 1.5, 50, and 1000 centistoke kinematic viscosities, and mercury. The experiments covered a range of Rayleigh numbers between 1.51(10)5 and 6.76(10)8. and Prandtl numbers between 0.02 and 8750. Tests were made in cylindrical containers having copper tops and bottoms and insulating walls. For water and silicone oils the container was 5 in. in diam and 2 in. high. For mercury, two containers were used, both 5.28 in. in diameter, but one 1.39 in. high and another 2.62 in. high. In all cases the bottom plates were heated by electric heaters. The top plates were air-cooled for the water and silicone-oil experiments and water-cooled for the mercury tests. To prevent amalgamation, the copper plates of the mercury container were chromium plated. Surface temperatures were measured by thermocouples embedded in the plates. The test results indicate that the heat-transfer coefficients for all liquids investigated may be determined from the relationship Nu=0.069Ra13Pr0.074 In this equation the Nusselt and Rayleigh numbers are based on the distance between the copper plates. The results of this experiment are in reasonable agreement with the data reported by others who used larger containers and different fluids.

1965 ◽  
Vol 87 (1) ◽  
pp. 77-82 ◽  
Author(s):  
D. Dropkin ◽  
E. Somerscales

This paper presents results of an experimental investigation of convective heat transfer in liquids confined by two parallel plates and inclined at various angles with respect to the horizontal. The experiments covered a range of Rayleigh numbers between 5(10)4 and 7.17(10)8, and Prandtl numbers between 0.02 and 11,560. Tests were made in rectangular and circular containers having copper plates and insulating walls. The liquids used were water, silicone oils, and mercury. The test results indicate that the heat transfer coefficients for all liquids investigated at the various angles, from horizontal to vertical, may be determined from the relationship Nu=C(Ra)1/3(Pr)0.074 The constant, C, is a function of the angle of inclination. It varies from C = 0.069 for the horizontal case when heated from below to C = 0.049 for the vertical case. For the test cells used, no effect on the Nusselt number had been detected for the vertical case by the change of the ratio of height of cell to distance between plates. The ratio for these tests was varied from 4.41 to 16.56.


1983 ◽  
Vol 105 (3) ◽  
pp. 433-439 ◽  
Author(s):  
N. Seki ◽  
S. Fukusako ◽  
A. Yamaguchi

Experimental measurements are presented for free convective heat transfer across a parallelogrammic enclosure with the various tilt angles of parallel upper and lower walls insulated. The experiments covered a range of Rayleigh numbers between 3.4 × 104 and 8.6 × 107, and Prandtl numbers between 0.70 and 480. Those also covered the tilt angles of the parallel insulated walls with respect to the horizontal, φ, of 0, ±25, ±45, ±60, and ±70 deg under an aspect ratio of H/W = 1.44. The fluids used were air, transformer oil, and water. It was found that the heat transfer coefficients for φ = −70 deg were decreased to be about 1/18 times those for φ = 0 deg. Experimental results are given as plots of the Nusselt number versus the Rayleigh number. A correlation equation is given for the Nusselt number, Nu, as a function of φ, Pr, and Ra.


2006 ◽  
Vol 129 (9) ◽  
pp. 1195-1202 ◽  
Author(s):  
Mohamed E. Ali

Experimental investigations have been reported on steady state natural convection from the outer surface of horizontal ducts in air. Five ducts have been used with aspect ratios (Γ=duct height/duct width) of 2, 1, and 0.5. The ducts are heated using internal constant heat flux heating elements. The temperatures along the surface and peripheral directions of the duct wall are measured. Longitudinal (circumference averaged) heat transfer coefficients along the side of each duct are obtained for laminar and transition regimes of natural convection heat transfer. Total overall averaged heat transfer coefficients are also obtained. Longitudinal (circumference averaged) Nusselt numbers are evaluated and correlated using the modified Rayleigh numbers for transition regime using the axial distance as a characteristic length. Furthermore, total overall averaged Nusselt numbers are correlated with the modified Rayleigh numbers, the aspect ratio, and area ratio for the laminar and transition regimes. The longitudinal or total averaged heat transfer coefficients are observed to decrease in the laminar region and to increase in the transition region. Laminar regimes are obtained only at very small heat fluxes, otherwise, transitions are observed.


Author(s):  
Mohamed E. Ali

Experimental investigations have been reported on steady state natural convection from the outer surface of vertical square ducts in air. Five ducts have been used with cross section side length of 0.08, 0.07, 0.06, 0.04, and 0.02 m. The ducts are heated using internal constant heat flux heating elements. The temperatures along the vertical surface and the peripheral directions of the duct wall are measured. Longitudinal (circumference averaged) heat transfer coefficients along the side of each duct are obtained for laminar and transition regimes of natural convection heat transfer. Total overall averaged heat transfer coefficients are also obtained. Longitudinal (circumference averaged) Nusselt numbers are evaluated and correlated using the modified Rayleigh numbers for transition regime using the axial distance as a characteristic length. Furthermore, total overall averaged Nusselt numbers are correlated with the modified Rayleigh numbers and the area ratio for the laminar regimes. The longitudinal or total averaged heat transfer coefficients are observed to decrease in the laminar region and increase in the transition region. Laminar regimes are obtained at the lower half of the ducts and its chance to appear decreases as the heat flux increases.


Author(s):  
Mohamed E. Ali ◽  
Hany Al-Ansary

Experimental investigations have been reported on steady state natural convection from the outer surface of vertical triangular cross section ducts in air. Three ducts have been used with equilateral side length of 0.044, 0.06 and 0.08 m. The ducts are heated using internal constant heat flux heating elements. The temperatures along the vertical surface and the peripheral directions of the duct wall are measured. Axial (perimeter averaged) heat transfer coefficients along the side of each duct are obtained for laminar and transition to turbulent regimes of natural convection heat transfer. Axial (perimeter averaged) Nusselt numbers are evaluated and correlated using the modified Rayleigh numbers for laminar and transition regime using the vertical axial distance as a characteristic length. Critical values of the modified Rayleigh numbers are obtained for transition to turbulent. Furthermore, total overall averaged Nusselt numbers are correlated with the modified Rayleigh numbers for all ducts. The local axial (perimeter averaged) heat transfer coefficients are observed to decrease in the laminar region and increase in the transition region. Laminar regimes are obtained at the lower half of the ducts and its chance to appear decreases as the heat flux increases.


1987 ◽  
Vol 109 (2) ◽  
pp. 388-391 ◽  
Author(s):  
E. M. Sparrow ◽  
M. A. Ansari

Measurements were made of the combined natural convection and radiation heat transfer from a horizontal finned tube situated in a vertical channel open at the top and bottom. In one set of experiments, both walls of the channel were heavily insulated, while in a second set of experiments, one of the insulated walls was replaced by an uninsulated metallic sheet. In general, the heat transfer coefficients were found to be lower with the metal wall in place, but only moderately. With the finned tube situated at the bottom of the channel, the differences in the heat transfer coefficients corresponding to the two types of walls were only a few percent. When the tube was positioned at the mid-height of the channel, larger differences were encountered, but in the practical range of Rayleigh numbers, the differences did not exceed 5 percent.


1990 ◽  
Vol 112 (3) ◽  
pp. 234-240 ◽  
Author(s):  
G. L. Lehmann ◽  
S. J. Kosteva

An experimental study of forced convection heat transfer is reported. Direct air cooling of an electronics packaging system is modeled by a channel flow, with an array of uniformly sized and spaced elements attached to one channel wall. The presence of a single or complete row of longitudinally finned heat sinks creates a modified flow pattern. Convective heat transfer rates at downstream positions are measured and compared to that of a plain array (no heat sinks). Heat transfer rates are described in terms of adiabatic heat transfer coefficients and thermal wake functions. Empirical correlations are presented for both variations in Reynolds number (5000 < Re < 20,000) and heat sink geometry. It is found that the presence of a heat sink can both enhance and degrade the heat transfer coefficient at downstream locations, depending on the relative position.


Author(s):  
Yantao Li ◽  
Yulong Ji ◽  
Katsuya Fukuda ◽  
Qiusheng Liu

Abstract This paper presents an experimental investigation of the forced convective heat transfer of FC-72 in vertical tubes at various velocities, inlet temperatures, and tube sizes. Exponentially escalating heat inputs were supplied to the small tubes with inner diameters of 1, 1.8, and 2.8 mm and effective heated lengths between 30.1 and 50.2 mm. The exponential periods of heat input range from 6.4 to 15.5 s. The experimental data suggest that the convective heat transfer coefficients increase with an increase in flow velocity and µ/µw (refers to the viscosity evaluated at the bulk liquid temperature over the liquid viscosity estimated at the tube inner surface temperature). When tube diameter and the ratio of effective heated length to inner diameter decrease, the convective heat transfer coefficients increase as well. The experimental data were nondimensionalized to explore the effect of Reynolds number (Re) on forced convection heat transfer coefficient. It was found that the Nusselt numbers (Nu) are influenced by the Re for d = 2.8 mm in the same pattern as the conventional correlations. However, the dependences of Nu on Re for d = 1 and 1.8 mm show different trends. It means that the conventional heat transfer correlations are inadequate to predict the forced convective heat transfer in minichannels. The experimental data for tubes with diameters of 1, 1.8, and 2.8 mm were well correlated separately. And, the data agree with the proposed correlations within ±15%.