Condensation Heat Transfer of Carbon Dioxide Inside Horizontal Smooth and Microfin Tubes at Low Temperatures

2008 ◽  
Vol 131 (2) ◽  
Author(s):  
Yoon Jo Kim ◽  
Jeremy Jang ◽  
Predrag S. Hrnjak ◽  
Min Soo Kim

This paper presents heat transfer data for the condensation of CO2 at low temperatures in horizontal smooth and microfin tubes. The test tubes included a 3.48 mm inner diameter smooth tube and a 3.51 mm melt-down diameter microfin tube. The test was performed over a mass flux range of 200–800 kg/m2 s and at saturation temperatures of −25°C and −15°C, respectively. The effect of various parameters—diameter, mass flux, vapor quality, and temperature difference between inner wall and refrigerant—on heat transfer coefficient and enhancement factor is analyzed. The data are compared with several correlations. The existing correlations for the smooth tube mostly overpredicted the heat transfer coefficients of the present study, which is possibly resulted from the characteristics of carbon dioxide as a “high pressure refrigerant.” For the microfin tubes, due to the complexity and variety of fin geometry and flow mechanisms in microfin tubes, most of the correlations for the microfin tube were not applicable for the experimental data of the present study. The average enhancement factors and penalty factors evidenced that it was not always true that the internally finned geometry guaranteed the superior in-tube condensation performance of the microfin tube in refrigeration and air-conditioning systems.

2005 ◽  
Vol 127 (12) ◽  
pp. 1305-1312 ◽  
Author(s):  
Chang Yong Park ◽  
Pega S. Hrnjak

Flow boiling heat transfer coefficients of CO2 are measured in a horizontal smooth tube with inner diameter 6.1mm. The test tube is heated by a secondary fluid maintaining constant wall temperature conditions. Heat transfer coefficients are measured at evaporation temperatures of −15 and −30°C, mass flux from 100to400kg∕m2s, and heat flux from 5to15kW∕m2 for qualities (vapor mass fractions) ranging from 0.1 to 0.8. The characteristics of CO2 flow boiling are explained by CO2 properties and flow patterns. The measured CO2 heat transfer coefficients are compared to other published data. Experiments with R22 were also conducted in the same system and the results show that the heat transfer coefficients for CO2 are 40 to 150% higher than for R22 at −15°C and low mass flux of 200kg∕m2s mostly due to the characteristics of CO2 nucleate boiling. The presented CO2 heat transfer coefficients indicate the reduction of heat transfer coefficient as mass flux increases at low quality regions and also show that dryout does not occur until the high quality region of 0.8, for mass fluxes of 200 and 400kg∕m2s. The Gungor and Winterton correlation gives a relatively good agreement with measured data; however it deviates more at lower evaporation temperature and high mass flux conditions.


Author(s):  
Eiji Hihara ◽  
Chaobin Dang

In this study, boiling heat transfer coefficients of carbon dioxide in horizontally located smooth tubes were experimentally investigated. The inner diameter of heat transfer tubes was 1, 2, 4, and 6 mm. Experiments were conducted at evaporating temperature of 5 and 15 °C, heat fluxes from 4.5 to 36 kW/m2, and mass fluxes from 360 to 1440 kg/m2s. The heat transfer coefficients in the pre-dryout region and post-dryout region were investigated, as well as the dryout quality. Due to the small viscosity and surface tension of CO2, the dryout occurs at a small quality from 0.4 to 0.7. The inception quality decreases with the increase of mass flux, and is affected by the heat flux and tube diameter; the effects of heat flux on the heat transfer coefficient are much significant in the pre-dryout region, which is related with the activation of nucleate boiling. On the contrary, the effects of mass flux are relatively low due to the low two-phase density ratio near the critical point. In addition, this tendency becomes more significant when the small tube is tested; In the post-dryout region, mass velocity is the dominating factor on heat transfer coefficient. At small mass flux, the heat transfer coefficient decreases with the increase of quality, while at large mass flux such as 1440kg/m2s, the heat transfer coefficient turns to increasing with the quality. By increasing the evaporating temperature, the pre-dryout heat transfer coefficient increases, while the dryout inception quality and post-dryout heat transfer coefficient are not affected greatly by the evaporating temperature.


Author(s):  
C. Y. Park ◽  
P. S. Hrnjak

In this study, flow boiling heat transfer coefficients and flow patterns CO2 are examined in horizontal smooth tubes with inner diameter 6.1 and 3.5 mm at low temperatures. In order to measure the heat transfer coefficients, the test tube was heated by two brass pieces maintained a higher temperature than CO2 by a secondary fluid. Flow visualization was carried out at adiabatic conditions. This research was performed at evaporation temperatures of -15 and -30 °C, mass flux from 100 to 400 kg/m2 s, and heat flux from 5 to 15 kW/m2 for vapor qualities ranging from 0.1 to 0.8. The CO2 heat transfer coefficients for the 6.1 and 3.5 mm tubes had nucleate boiling dominant heat transfer characteristics such as the strong dependence on heat fluxes. However, enhanced convective boiling contribution was presented for the 3.5 mm tube at 400 kg/m2 s. The presented heat transfer coefficients indicated the reduction of heat transfer coefficient as mass flux increased at low quality regions and also showed that dryout did not occur until the high quality region of 0.8, for mass fluxes of 200 and 400 kg/m2 s. The measured heat transfer coefficients were compared with predicted values with some general correlations to predict flow boiling heat transfer coefficients. The pictures of visualized flow patterns were presented and the flow patterns were compared with a flow pattern map. They were used to explain the relation between the flow boiling heat transfer coefficient and vapor quality at the mass flux of 100 kg/m2 s.


1990 ◽  
Vol 112 (4) ◽  
pp. 1041-1047 ◽  
Author(s):  
L. M. Schlager ◽  
M. B. Pate ◽  
A. E. Bergles

Using R-22 as the working fluid, a series of tests was performed to determine the evaporation and condensation performance of three 12.7-mm o.d. tubes having many small, spiral inner fins. The tubes, referred to as microfin tubes, had a 11.7-mm maximum i.d., 60 or 70 fins with heights ranging from 0.15 to 0.30 mm, and spiral angles from 15 to 25 deg. A smooth tube was also tested to establish a basis of comparison. The test apparatus had a straight, horizontal test section with a length of 3.67 m and was heated or cooled by water circulated in a surrounding annulus. Nominal evaporation conditions were 0 to 5°C (0.5 to 0.6 MPa) with inlet and outlet qualities of 15 and 85 percent, respectively; condensation conditions were 39 to 42°C (1.5 to 1.6 MPa) with inlet and outlet qualities of 85 and 10 percent, respectively. Mass flux varied from 75 to 400 kg/m2·s. The average heat transfer coefficients in the microfin tubes, based on a nominal equivalent smooth tube area, were 1.6 to 2.2 times larger for evaporation and 1.5 to 2.0 times larger for condensation than those in the smooth tube. The pressure drop increased, but by a smaller factor than the heat transfer coefficient.


Author(s):  
Jian-jun Sun ◽  
Jing-xiang Chen ◽  
David J. Kukulka ◽  
Kan Zhou ◽  
Wei Li ◽  
...  

An experiment investigation was performed using R410A in order to determine the single-phase and evaporation heat transfer coefficients on the outside of (i) a smooth tube; (ii) herringbone tube; and (iii) the newly developed Vipertex enhanced surface 1EHT tube; all with the same external diameter (12.7 mm). The nominal evaporation temperature is 279 K, with inlet and outlet qualities of 0.1 and 0.8. Mass fluxes ranged from 10 to 40 kg m−2s−1. Results suggest that the 1EHT tube has excellent heat transfer performance but a higher pressure drop when compared to a smooth tube. Evaporation heat transfer coefficient for the 1EHT is lower than the herringbone tube and the pressure drop is almost the same.


Author(s):  
Koichi Araga ◽  
Keisuke Okamoto ◽  
Keiji Murata

This paper presents an experimental investigation of the forced convective boiling of refrigerant HCFC123 in a mini-tube. The inner diameters of the test tubes, D, were 0.51 mm and 0.30 mm. First, two-phase frictional pressure drops were measured under adiabatic conditions and compared with the correlations for conventional tubes. The frictional pressure drop data were lower than the correlation for conventional tubes. However, the data were qualitatively in accord with those for conventional tubes and were correlated in the form φL2−1/Xtt. Next, heat transfer coefficients were measured under the conditions of constant heat flux and compared with those for conventional tubes and for pool boiling. The heat transfer characteristics for mini-tubes were different from those for conventional tubes and quite complicated. The heat transfer coefficients for D = 0.51 mm increased with heat flux but were almost independent of mass flux. Although the heat transfer coefficients were higher than those for a conventional tube with D = 10.3 mm and for pool boiling in the low quality region, they decreased gradually with increasing quality. The heat transfer coefficients for D = 0.30 mm were higher than those for D = 0.51 mm and were almost independent of both mass flux and heat flux.


1981 ◽  
Vol 103 (4) ◽  
pp. 705-714 ◽  
Author(s):  
J. C. Biery

A new method is presented to predict heat transfer coefficients for gas flow normal to smooth and finned tube tanks with triangular pitch. A transformation from the actual tube bank to an equivalent equilateral triangular pitch infinite smooth tube bank (ETP-I-STB) is made. A function of Ch(Ch = NSTNPR2/3NRe0.4) versus (Xt D0)Δ, ratio of transverse pitch to tube diameter for the ETP-I-STB, was developed. The Ch for the equivalent ETP-I-STP then applies to the actual tube bank. The method works with circular finned tubes, smooth tubes, continuous finned tubes, and segmented finned tubes with any triangular pitch. Also, fair predictions were made for in-line tubes with high Reynolds numbers.


2009 ◽  
Vol 131 (9) ◽  
Author(s):  
Chang Yong Park ◽  
Pega Hrnjak

Abstract C O 2 flow boiling heat transfer coefficients and pressure drop in a 3.5mm horizontal smooth tube are presented. Also, flow patterns were visualized and studied at adiabatic conditions in a 3mm glass tube located immediately after a heat transfer section. Heat was applied by a secondary fluid through two brass half cylinders to the test section tubes. This research was performed at evaporation temperatures of −15°C and −30°C, mass fluxes of 200kg∕m2s and 400kg∕m2s, and heat flux from 5kW∕m2 to 15kW∕m2 for vapor qualities ranging from 0.1 to 0.8. The CO2 heat transfer coefficients indicated the nucleate boiling dominant heat transfer characteristics such as the strong dependence on heat fluxes at a mass flux of 200kg∕m2s. However, enhanced convective boiling contribution was observed at 400kg∕m2s. Surface conditions for two different tubes were investigated with a profilometer, atomic force microscope, and scanning electron microscope images, and their possible effects on heat transfer are discussed. Pressure drop, measured at adiabatic conditions, increased with the increase of mass flux and quality, and with the decrease of evaporation temperature. The measured heat transfer coefficients and pressure drop were compared with general correlations. Some of these correlations showed relatively good agreements with measured values. Visualized flow patterns were compared with two flow pattern maps and the comparison showed that the flow pattern maps need improvement in the transition regions from intermittent to annular flow.