Prediction of Heat Transfer Coefficients in Gas Flow Normal to Finned and Smooth Tube Banks

1981 ◽  
Vol 103 (4) ◽  
pp. 705-714 ◽  
Author(s):  
J. C. Biery

A new method is presented to predict heat transfer coefficients for gas flow normal to smooth and finned tube tanks with triangular pitch. A transformation from the actual tube bank to an equivalent equilateral triangular pitch infinite smooth tube bank (ETP-I-STB) is made. A function of Ch(Ch = NSTNPR2/3NRe0.4) versus (Xt D0)Δ, ratio of transverse pitch to tube diameter for the ETP-I-STB, was developed. The Ch for the equivalent ETP-I-STP then applies to the actual tube bank. The method works with circular finned tubes, smooth tubes, continuous finned tubes, and segmented finned tubes with any triangular pitch. Also, fair predictions were made for in-line tubes with high Reynolds numbers.

1978 ◽  
Vol 100 (1) ◽  
pp. 17-24 ◽  
Author(s):  
J. H. Royal ◽  
A. E. Bergles

Low pressure steam was condensed inside horizontal tubes of different internal geometries to investigate passive heat transfer augmentation techniques. A smooth tube, the smooth tube having two twisted-tape inserts, and four internally finned tubes were tested. The twisted-tape inserts were found to increase average heat transfer coefficients by as much as 30 percent above smooth tube values on a nominal area basis. The best performing internally finned tube increased average heat transfer coefficients by 150 percent above the nominal smooth tube values. Techniques were developed to correlate the improved heat transfer performance of the two twisted-tape inserts and the four internally finned tubes. The equations developed provide a reasonably accurate description of both the sectional and the average heat transfer coefficients. The finned tube correlation was also reasonably successful in predicting the data from the one other investigation of this augmentation technique for which detailed data were available.


Author(s):  
Ignacio Carvajal-Mariscal ◽  
Florencio Sanchez-Silva ◽  
Georgiy Polupan

In this work the heat transfer and pressure drop experimental results obtained in a two step finned tube bank with conical fins are presented. The tube bank had an equilateral triangle array composed of nine finned tubes with conical fins inclined 45 degrees in respect with the tube axis. The heat exchange external area of a single tube is approximately 0.07 m2. All necessary thermal parameters, inlet/outlet temperatures, mass flows, for the heat balance in the tube bank were determined for different air velocities, Re = 3400–18400, and one constant thermal charge provided by a hot water flow with a temperature of 80 °C. As a result, the correlations for the heat transfer and pressure drop calculation were obtained. The experimental results were compared against the analytical results for a tube bank with annular fins with the same heat exchange area. It was found that the proposed tube bank using finned tubes with conical fins shows an increment of heat transfer up to 58%.


1964 ◽  
Vol 86 (2) ◽  
pp. 143-148 ◽  
Author(s):  
C. P. Welch ◽  
H. N. Fairchild

Individual row heat-transfer coefficients are presented for air flowing across 10-row in-line tube banks at close back spacings with heat flow from air to tube. The Reynolds number range covered is approximately 1000 to 20,000 with heat fluxes of 640 Btu/hr-sq ft to 12,500 Btu/hr-sq ft. The effect of both tube row number and Reynolds number is shown. These effects are different for tangent (tubes touching in direction of airflow) and nontangent tubes.


1987 ◽  
Vol 109 (2) ◽  
pp. 388-391 ◽  
Author(s):  
E. M. Sparrow ◽  
M. A. Ansari

Measurements were made of the combined natural convection and radiation heat transfer from a horizontal finned tube situated in a vertical channel open at the top and bottom. In one set of experiments, both walls of the channel were heavily insulated, while in a second set of experiments, one of the insulated walls was replaced by an uninsulated metallic sheet. In general, the heat transfer coefficients were found to be lower with the metal wall in place, but only moderately. With the finned tube situated at the bottom of the channel, the differences in the heat transfer coefficients corresponding to the two types of walls were only a few percent. When the tube was positioned at the mid-height of the channel, larger differences were encountered, but in the practical range of Rayleigh numbers, the differences did not exceed 5 percent.


2009 ◽  
Vol 131 (7) ◽  
Author(s):  
Akhilesh P. Rallabandi ◽  
Huitao Yang ◽  
Je-Chin Han

Systematic experiments are conducted to measure heat transfer enhancement and pressure loss characteristics on a square channel (simulating a gas turbine blade cooling passage) with two opposite surfaces roughened by 45 deg parallel ribs. Copper plates fitted with a silicone heater and instrumented with thermocouples are used to measure regionally averaged local heat transfer coefficients. Reynolds numbers studied in the channel range from 30,000 to 400,000. The rib height (e) to hydraulic diameter (D) ratio ranges from 0.1 to 0.18. The rib spacing (p) to height ratio (p/e) ranges from 5 to 10. Results show higher heat transfer coefficients at smaller values of p/e and larger values of e/D, though at the cost of higher friction losses. Results also indicate that the thermal performance of the ribbed channel falls with increasing Reynolds numbers. Correlations predicting Nusselt number (Nu) and friction factor (f¯) as a function of p/e, e/D, and Re are developed. Also developed are correlations for R and G (friction and heat transfer roughness functions, respectively) as a function of the roughness Reynolds number (e+), p/e, and e/D.


Author(s):  
Jian-jun Sun ◽  
Jing-xiang Chen ◽  
David J. Kukulka ◽  
Kan Zhou ◽  
Wei Li ◽  
...  

An experiment investigation was performed using R410A in order to determine the single-phase and evaporation heat transfer coefficients on the outside of (i) a smooth tube; (ii) herringbone tube; and (iii) the newly developed Vipertex enhanced surface 1EHT tube; all with the same external diameter (12.7 mm). The nominal evaporation temperature is 279 K, with inlet and outlet qualities of 0.1 and 0.8. Mass fluxes ranged from 10 to 40 kg m−2s−1. Results suggest that the 1EHT tube has excellent heat transfer performance but a higher pressure drop when compared to a smooth tube. Evaporation heat transfer coefficient for the 1EHT is lower than the herringbone tube and the pressure drop is almost the same.


Author(s):  
F. W. Staub

To improve the reliability of turbine disc life prediction, experimental verification is required of analytical tools that calculate the flow field and heat transfer coefficients in turbine-stator cavities. As a first step, a full-scale model of the forward cavity of a typical aircraft gas turbine was employed using a high-molecular-weight gas (Refrigerant-12) at ambient pressure and temperature conditions to match the dimensionless parameters at engine conditions. The cavity temperature and selected cavity velocity profiles were measured using electrical heat addition with liquid crystal surface temperature measurement to obtain local disc heat transfer coefficients. A part of the cooling gas flow was added through a rotating inner seal with the remainder added at high angular swirl in the direction of rotation at a larger radius. Rotational Reynolds numbers were varied up to 9×106 with the radial Reynolds number variation up to 9000. A first-order comparison is given of the velocity distribution and disc heat transfer coefficients calculated by a CFD code and the measured values. The disc heat transfer coefficients can be dominated by the inlet swirl flow or by the rotor speed, depending on whether the coolant flow is greater or smaller than that generated by the rotor alone acting as a free disc.


Author(s):  
Makoto Shibahara ◽  
Qiusheng Liu ◽  
Katsuya Fukuda

Forced convection transient heat transfer coefficients were measured for helium gas and carbon dioxide gas flowing over a twisted heater due to exponentially increasing heat input (Q0exp(t/τ)). The twisted platinum plate with a thickness of 0.1 mm was used as test heater and heated by electric current. The heat generation rate was exponentially increased with a function of Q0exp(t/τ). The gas flow velocities ranged from 1 to 10 m/s, the gas temperatures ranged from 313 to 353 K, and the periods of heat generation rate ranged from 46 ms to 17 s. The surface temperature difference and heat flux increase exponentially as the heat generation rate increases with the exponential function. Transient heat transfer coefficients increase with increasing gas flow velocity. The geometric effect of twisted heater in this study shows an enhancement on the heat transfer coefficient. Empirical correlation for quasi-steady-state heat transfer was obtained based on the experimental data. The data for heat transfer coefficient were compared with those reported in authors’ previous paper.


Author(s):  
Bin Ren ◽  
Xiaoying Tang ◽  
Hongliang Lu ◽  
Dongliang Fu ◽  
Yannan Du ◽  
...  

It is the simplest and most feasible method to enhance heat transfer by replacing the smooth tube with various kinds of special-shaped enhanced tubes. In this paper, the characteristics of condensation and flow resistance inside horizontal corrugated low finned tubes were studied experimentally. The effects of steam inlet conditions and condensation tubes structural parameters were analyzed. The results showed that the heat transfer performance inside corrugated low finned tubes was greater than that inside smooth tubes. Like inside smooth tubes, the heat transfer coefficients increased with the vapor quality and steam mass flux. But the enhancement rate showed the opposite trend. And the heat transfer coefficients inside corrugated low finned tubes increased with the decrease of pitch and increase of protrusion height. Meanwhile, the variation trend of pressure drop gradient changing with inlet conditions and construal parameters was consistent with trend of heat transfer coefficient. The performance evaluation criteria were used to evaluate the comprehensive performance. It was found that the maximum performance evaluation factor was acquired at the minimum vapor quality and mass flux. The maximum value was 2.24 happened in the tube with pitch of 6 mm and height of 0.7mm. Finally, both the correlation for heat transfer coefficient and correlation for pressure drop gradient were developed by fitting experimental data. And this would provide calculation foundations for the design of horizontal condensers with corrugated low finned tubes.


Sign in / Sign up

Export Citation Format

Share Document