Effects of Simulated Rotation on Tip Leakage in a Planar Cascade of Turbine Blades: Part II—Downstream Flow Field and Blade Loading

1992 ◽  
Vol 114 (3) ◽  
pp. 660-667 ◽  
Author(s):  
M. I. Yaras ◽  
S. A. Sjolander ◽  
R. J. Kind

This paper and its companion paper present experimental results on the effects of simulated rotation on the tip leakage in a linear turbine cascade test. Part II examines the downstream flow field. For clearance sizes of 2.4 and 3.8 percent of the blade chord, measurements were made in two planes downstream of the trailing edge using a seven-hole pressure probe. Significant changes in the tip leakage vortex and passage vortex structures are observed with the introduction of relative motion. The effects of clearance size and rotation on the relationship between bound circulation and tip-vortex circulation are discussed. The validity of a previously developed tip-vortex model for the case of rotation is examined in the light of the measurements. Finally, for clearances of 1.5, 2.4, and 3.8 percent of the blade chord, the effects of rotation on blade loading are studied through static pressure measurements on the blade surfaces. The distortion of the surface pressure field near the tip is found to be reduced with increasing wall speed. This is consistent with the reduced strength of the tip-leakage vortex as wall speed is increased. For all measurements two wall speeds are considered and the results are compared with the case of no rotation.

Author(s):  
M. I. Yaras ◽  
S. A. Sjolander ◽  
R. J. Kind

This paper and its companion paper present experimental results on the effects of simulated rotation on the tip leakage in a linear turbine cascade test. Part II examines the downstream flow field. For clearance sizes of 2.4 and 3.8 percent of the blade chord measurements were made in two planes downstream of the trailing edge using a seven-hole pressure probe. Significant changes in the tip leakage vortex and passage vortex structures are observed with the introduction of relative motion. The effects of clearance size and rotation on the relationship between bound circulation and tip-vortex circulation are discussed. The validity of a previously developed tip-vortex model for the case of rotation is examined in the light of the measurements. Finally, for clearances of 1.5, 2.4 and 3.8 percent of the blade chord the effects of rotation on blade loading are studied through static pressure measurements on the blade surfaces. The distortion of the surface pressure field near the tip is found to be reduced with increasing wall speed. This is consistent with the reduced strength of the tip-leakage vortex as wall speed is increased. For all measurements two wall speeds are considered and the results are compared with the case of no rotation.


Author(s):  
M. I. Yaras ◽  
S. A. Sjolander

The paper presents further results from a continuing study on tip leakage in axial turbines. Rotation has been simulated in a linear cascade test section by using a moving-belt tip wall. Measurements were made inside the tip gap with a three-hole pressure probe for a clearance size of 3.8 percent of the blade chord. Two wall speeds are considered and the results are compared with the case of no rotation. As in other experiments, significant reduction in the gap mass flow rate is observed due to the relative motion. The detailed nature of the measurements allows the dominant physical mechanism by which wall motion affects the tip gap flow to be identified. Based on the experimental observations, an earlier model for predicting the tip gap flow field is extended to the case of relative wall motion. Part II of the paper examines the effect of the relative motion on the downstream flow field and the blade loading.


1992 ◽  
Vol 114 (3) ◽  
pp. 652-659 ◽  
Author(s):  
M. I. Yaras ◽  
S. A. Sjolander

The paper presents further results from a continuing study on tip leakage in axial turbines. Rotation has been simulated in a linear cascade test section by using a moving-belt tip wall. Measurements were made inside the tip gap with a three-hole pressure probe for a clearance size of 3.8 percent of the blade chord. Two wall speeds are considered and the results are compared with the case of no rotation. As in other experiments, significant reduction in the gap mass flow rate is observed due to the relative motion. The detailed nature of the measurements allows the dominant physical mechanism by which wall motion affects the tip gap flow to be identified. Based on the experimental observations, an earlier model for predicting the tip gap flow field is extended to the case of relative wall motion. Part II of the paper examines the effect of the relative motion on the downstream flow field and the blade loading.


Author(s):  
Masanao Kaneko ◽  
Hoshio Tsujita

A transonic centrifugal compressor impeller is generally composed of the main and the splitter blades which are different in chord length. As a result, the tip leakage flows from the main and the splitter blades interact with each other and then complicate the flow field in the compressor. In this study, in order to clarify the individual influences of these leakage flows on the flow field in the transonic centrifugal compressor stage at near-choke to near-stall condition, the flows in the compressor at four conditions prescribed by the presence and the absence of the tip clearances were analyzed numerically. The computed results clarified the following noticeable phenomena. The tip clearance of the main blade induces the tip leakage vortex from the leading edge of the main blade. This vortex decreases the blade loading of the main blade to the negative value by the increase of the flow acceleration along the suction surface of the splitter blade, and consequently induces the tip leakage vortex caused by the negative blade loading of the main blade at any operating points. These phenomena decline the impeller efficiency. On the other hand, the tip clearance of the splitter blade decreases the afore mentioned acceleration by the formation of the tip leakage vortex from the leading edge of the splitter blade and the decrease of the incidence angle for the splitter blade caused by the suction of the flow into the tip clearance. These phenomena reduce the loss generated by the negative blade loading of the main blade and consequently reduce the decline of the impeller efficiency. Moreover, the tip clearances enlarge the flow separation around the diffuser inlet and then decline the diffuser performance independently of the operating points.


2001 ◽  
Vol 123 (4) ◽  
pp. 748-754 ◽  
Author(s):  
Choon-Man Jang ◽  
Masato Furukawa ◽  
Masahiro Inoue

Three-dimensional structures of the vortical flow field in a propeller fan with a shroud covering only the rear region of its rotor tip have been investigated by experimental analysis using laser Doppler velocimetry (LDV) measurements and by numerical analysis using a large eddy simulation (LES) in Part I of the present study. The propeller fan has a very complicated vortical flow field near the rotor tip compared with axial fan and compressor rotors. It is found that three vortex structures are formed near the rotor tip: the tip vortex, the leading edge separation vortex, and the tip leakage vortex. The tip vortex is so strong that it dominates the flow field near the tip. Its formation starts from the blade tip suction side near the midchord. Even at the design condition the tip vortex convects nearly in the tangential direction, thus impinging on the pressure surface of the adjacent blade. The leading edge separation vortex develops close along the tip suction surface and disappears in the rear region of the rotor passage. The tip leakage vortex is so weak that it does not affect the flow field in the rotor.


1997 ◽  
Vol 119 (1) ◽  
pp. 122-128 ◽  
Author(s):  
S. L. Puterbaugh ◽  
W. W. Copenhaver

An experimental investigation concerning tip flow field unsteadiness was performed for a high-performance, state-of-the-art transonic compressor rotor. Casing-mounted high frequency response pressure transducers were used to indicate both the ensemble averaged and time varying flow structure present in the tip region of the rotor at four different operating points at design speed. The ensemble averaged information revealed the shock structure as it evolved from a dual shock system at open throttle to an attached shock at peak efficiency to a detached orientation at near stall. Steady three-dimensional Navier Stokes analysis reveals the dominant flow structures in the tip region in support of the ensemble averaged measurements. A tip leakage vortex is evident at all operating points as regions of low static pressure and appears in the same location as the vortex found in the numerical solution. An unsteadiness parameter was calculated to quantify the unsteadiness in the tip cascade plane. In general, regions of peak unsteadiness appear near shocks and in the area interpreted as the shock-tip leakage vortex interaction. Local peaks of unsteadiness appear in mid-passage downstream of the shock-vortex interaction. Flow field features not evident in the ensemble averaged data are examined via a Navier-Stokes solution obtained at the near stall operating point.


2013 ◽  
Vol 2013 ◽  
pp. 1-19 ◽  
Author(s):  
Matteo Pascotto ◽  
Alessandro Armellini ◽  
Luca Casarsa ◽  
Claudio Mucignat ◽  
Pietro Giannattasio

The flow field inside a cooling channel for the trailing edge of gas turbine blades has been numerically investigated with the aim to highlight the effects of channel rotation and orientation. A commercial 3D RANS solver including a SST turbulence model has been used to compute the isothermal steady air flow inside both static and rotating passages. Simulations were performed at a Reynolds number equal to 20000, a rotation number (Ro) of 0, 0.23, and 0.46, and channel orientations ofγ=0∘, 22.5°, and 45°, extending previous results towards new engine-like working conditions. The numerical results have been carefully validated against experimental data obtained by the same authors for conditionsγ=0∘and Ro = 0, 0.23. Rotation effects are shown to alter significantly the flow field inside both inlet and trailing edge regions. These effects are attenuated by an increase of the channel orientation fromγ=0∘to 45°.


2013 ◽  
Vol 136 (4) ◽  
Author(s):  
William Riéra ◽  
Lionel Castillon ◽  
Julien Marty ◽  
Francis Leboeuf

In the present study, the influence of the inlet condition on the tip clearance flow of an axial compressor is investigated. Two different zonal detached eddy simulations (ZDES) computations are carried out and compared to Reynolds-averaged Navier–Stokes (RANS) and unsteady RANS (URANS) computations as well as to experimental data. A rotating distortion map of the flow cartography is set as inlet condition for the first ZDES computation. An azimuthally averaged inlet condition is used for the second one and uncouples the rotor tip-leakage vortex flutter phenomenon, which stems from the arrival of the inlet guide vane wake from the behavior inherent to the rotor tip-leakage vortex. In the studied configuration, the inlet guide vane tip vortex reveals to lower the effects from double leakage on the rotor. The topology of the rotor tip-leakage vortex is described, and its development is analyzed.


2007 ◽  
Vol 130 (1) ◽  
Author(s):  
P. Palafox ◽  
M. L. G. Oldfield ◽  
J. E. LaGraff ◽  
T. V. Jones

New, detailed flow field measurements are presented for a very large low-speed cascade representative of a high-pressure turbine rotor blade with turning of 110deg and blade chord of 1.0m. Data were obtained for tip leakage and passage secondary flow at a Reynolds number of 4.0×105, based on exit velocity and blade axial chord. Tip clearance levels ranged from 0% to 1.68% of blade span (0% to 3% of blade chord). Particle image velocimetry was used to obtain flow field maps of several planes parallel to the tip surface within the tip gap, and adjacent passage flow. Vector maps were also obtained for planes normal to the tip surface in the direction of the tip leakage flow. Secondary flow was measured at planes normal to the blade exit angle at locations upstream and downstream of the trailing edge. The interaction between the tip leakage vortex and passage vortex is clearly defined, revealing the dominant effect of the tip leakage flow on the tip end-wall secondary flow. The relative motion between the casing and the blade tip was simulated using a motor-driven moving belt system. A reduction in the magnitude of the undertip flow near the end wall due to the moving wall is observed and the effect on the tip leakage vortex examined.


1993 ◽  
Vol 115 (3) ◽  
pp. 435-443 ◽  
Author(s):  
S. Kang ◽  
C. Hirsch

Experimental results from a study of the three-dimensional flow in a linear compressor cascade with stationary endwall at design conditions are presented for tip clearance levels of 1.0, 2.0, and 3.3 percent of chord, compared with the no-clearance case. In addition to five-hole probe measurements, extensive surface flow visualizations are conducted. It is observed that for the smaller clearance cases a weak horseshoe vortex forms in the front of the blade leading edge. At all the tip gap cases, a multiple tip vortex structure with three discrete vortices around the midchord is found. The tip leakage vortex core is well defined after the midchord but does not cover a significant area in traverse planes. The presence of the tip leakage vortex results in the passage vortex moving close to the endwall and the suction side.