A Correlation for Heat Transfer and Wake Effect in the Entrance Region of an In-Line Array of Rectangular Blocks Simulating Electronic Components

1995 ◽  
Vol 117 (1) ◽  
pp. 40-46 ◽  
Author(s):  
M. Molki ◽  
M. Faghri ◽  
O. Ozbay

An experimental investigation is carried out to study heat transfer in the entrance region of an array of rectangular heated blocks. The focus of the work is on the entrance heat transfer coefficients and the associated thermal wake effects. The experiments were performed with air as the working fluid. The geometric parameters of the array were varied in the range identified with B/L = 0.5, S/L = 0.128–0.33, and H/L = 0.128–1. The Reynolds number, based on the height above the blocks and the fluid mean velocity in the bypass channel, ranged from 3000 to 15,000. The adiabatic heat transfer coefficients and thermal wake effects are correlated for the entrance region. These correlations are incorporated into a user-friendly FORTRAN program, which can be used by the engineers to predict the working temperatures of the components of circuit boards with similar layout. A typical computer output indicated that the mean deviation between the measured and predicted temperatures is 11.0 percent.

Author(s):  
Shang-Feng Yang ◽  
Je-Chin Han ◽  
Salam Azad ◽  
Ching-Pang Lee

This paper experimentally investigates the effect of rotation on heat transfer in typical turbine blade serpentine coolant passage with ribbed walls at low Mach numbers. To achieve the low Mach number (around 0.01) condition, pressurized Freon R-134a vapor is utilized as the working fluid. The flow in the first passage is radial outward, after the 180 deg tip turn the flow is radial inward to the second passage, and after the 180 deg hub turn the flow is radial outward to the third passage. The effects of rotation on the heat transfer coefficients were investigated at rotation numbers up to 0.6 and Reynolds numbers from 30,000 to 70,000. Heat transfer coefficients were measured using the thermocouples-copper-plate-heater regional average method. Heat transfer results are obtained over a wide range of Reynolds numbers and rotation numbers. An increase in heat transfer rates due to rotation is observed in radially outward passes; a reduction in heat transfer rate is observed in the radially inward pass. Regional heat transfer coefficients are correlated with Reynolds numbers for nonrotation and with rotation numbers for rotating condition, respectively. The results can be useful for understanding real rotor blade coolant passage heat transfer under low Mach number, medium–high Reynolds number, and high rotation number conditions.


Author(s):  
Vikrant Saxena ◽  
Hasan Nasir ◽  
Srinath V. Ekkad

A comprehensive investigation of the effect of various tip sealing geometries is presented on the blade tip leakage flow and associated heat transfer of a scaled up HPT turbine blade in a low-speed wind tunnel facility. The linear cascade is made of four blades with the two corner blades acting as guides. The tip section of a HPT first stage rotor blade is used to fabricate the 2-D blade. The wind tunnel accommodates an 116° turn for the blade cascade. The mainstream Reynolds number based on the axial chord length at cascade exit is 4.83 × 105. The upstream wake effect is simulated with a spoked wheel wake generator placed upstream of the cascade. A turbulence grid placed even farther upstream generates the required free-stream turbulence of 4.8%. The center blade has a tip clearance gap of 1.5625% with respect to the blade span. Static pressure measurements are obtained on the blade surface and the shroud. The effect of crosswise trip strips to reduce leakage flow and associated heat transfer is investigated with strips placed along the leakage flow direction, against the leakage flow and along the chord. Cylindrical pin fins and pitch variation of strips over the tip surface are also investigated. Detailed heat transfer measurements are obtained using a steady state HSI-based liquid crystal technique. The effect of periodic unsteady wake effect is also investigated by varying the wake Strouhal number from 0. to 0.2, and to 0.4. Results show that the trip strips placed against the leakage flow produce the lowest heat transfer on the tips compared to all the other cases with a reduction between 10–15% compared to the plain tip. Results also show that the pitch of the strips has a small effect on the overall reduction. Cylindrical pins fins and strips along the leakage flow direction do not decrease the heat transfer coefficients and in some cases enhance the heat transfer coefficients by as much as 20%.


2020 ◽  
Vol 10 (15) ◽  
pp. 5225
Author(s):  
Barbara Arevalo-Torres ◽  
Jose L. Lopez-Salinas ◽  
Alejandro J. García-Cuéllar

The curved geometry of a coiled flow inverter (CFI) promotes chaotic mixing through a combination of coils and bends. Besides the heat exchanger geometry, the heat transfer can be enhanced by improving the thermophysical properties of the working fluid. In this work, aqueous solutions of dispersed TiO2 nanometer-sized particles (i.e., nanofluids) were prepared and characterized, and their effects on heat transfer were experimentally investigated in a CFI heat exchanger inserted in a forced convective thermal loop. The physical and transport properties of the nanofluids were measured within the temperature and volume concentration domains. The convective heat transfer coefficients were obtained at Reynolds numbers (NRe) and TiO2 nanoparticle volume concentrations ranging from 1400 to 9500 and 0–1.5 v/v%, respectively. The Nusselt number (NNu) in the CFI containing 1.0 v/v% nanofluid was 41–52% higher than in the CFI containing pure base fluid (i.e., water), while the 1.5 v/v% nanofluid increased the NNu by 4–8% compared to water. Two new correlations to predict the NNu of TiO2–water nanofluids in the CFI at Reynolds numbers of 1400 ≤ NRe ≤ 9500 and nanoparticle volume concentrations ranges of 0.2–1.0 v/v% and 0.2–1.5 v/v% are proposed.


Author(s):  
G. Angelino

The potential performance of carbon dioxide as working fluid is recognized to be similar to that of steam, which justifies thorough thermodynamic analysis of possible cycles. The substantially better results achievable with CO2 with respect to other gases are due to the real gas behaviour in the vicinity of the Andrews curve. Simple cycles benefit from the reduced compression work, but their efficiency is compromised by significant losses caused by irreversible heat transfer. Their economy, however, is appreciably better than that of perfect gas cycles. More complex cycle arrangements, six of which are proposed and analyzed in detail, reduce heat transfer losses while maintaining the advantage of low compression work and raise cycle efficiency to values attained only by the best steam practice. Some of the cycles presented were conceived to give a good efficiency at moderate pressure which is of particular value in direct-cycle nuclear applications. The favourable influence on heat transfer coefficients of the combined variation with pressure of mechanical, thermal and transport properties, due to real gas effects, is illustrated. Technical aspects as turbo-machines dimensions and heat transfer surfaces needed for regeneration are also considered. Cooling water requirements are found to be not much more stringent than in steam stations.


1994 ◽  
Vol 116 (4) ◽  
pp. 921-928 ◽  
Author(s):  
S. Ou ◽  
J. C. Han

The effect of unsteady wake and film injection on heat transfer coefficients and film effectiveness from a gas turbine blade was found experimentally. A spoked wheel type wake generator produced the unsteady flow. Experiments were done with a five airfoil linear cascades in a low-speed wind tunnel at a chord Reynolds number of 3 × 105, two wake Strouhal numbers of 0.1 and 0.3, and a no-wake case. A model turbine blade injected air or CO2 through one row of film holes each on the pressure and suction surfaces. The results show that the large-density injectant (CO2) causes higher heat transfer coefficients on the suction surface and lower heat transfer coefficients on the pressure surface. At the higher blowing ratios of 1.0 and 1.5, the film effectiveness increases with increasing injectant-to-mainstream density ratio at a given Strouhal number. However, the density ratio effect on film effectiveness is reversed at the lowest blowing ratio of 0.5. Higher wake Strouhal numbers enhance the heat transfer coefficients but reduce film effectiveness for both density ratio injectants at all three blowing ratios. The effect of the wake Strouhal number on the heat transfer coefficients on the suction surface is greater than that on the pressure surface.


2002 ◽  
Vol 124 (5) ◽  
pp. 975-978 ◽  
Author(s):  
Li Yong and ◽  
K. Sumathy

Quasi-local absorption heat transfer coefficients and pressure drop inside a horizontal tube absorber have been investigated experimentally, with R-22/DMA as the working pair. The absorber is a counterflow coaxial tube-in-tube heat-exchanger with the working fluid flowing in the inner tube while the water moves through the annulus. A large temperature gliding has been experienced during the absorption process. Experimental results show that the heat transfer coefficient of the forced convective vapor absorption process is higher compared to the vertical falling film absorption. A qualitative study is made to analyze the effect of mass flux, vapor quality and solution concentration on pressure drop and heat transfer coefficients. On the basis of the experimental results, a new correlation is proposed whereby the two-phase heat transfer is taken as a product of the forced convection of the absorption and the combined effect of heat and mass transfer at the interface. The correlation is found to predict the experimental data almost within 30 percent.


2013 ◽  
Vol 136 (1) ◽  
Author(s):  
Justin A. Lamont ◽  
Srinath V. Ekkad ◽  
Mary Anne Alvin

The effects of Coriolis force and centrifugal buoyancy have a significant impact on heat transfer behavior inside rotating internal serpentine coolant channels for turbine blades. Due to the complexity of added rotation inside such channels, detailed knowledge of the heat transfer will greatly enhance the blade designer's ability to predict hot spots so coolant may be distributed more effectively. The effects of high rotation numbers are investigated on the heat transfer distributions for different rib types in near entrance and entrance region of the channels. It is important to determine the actual enhancement derived from turbulating channel entrances where heat transfer is already high due to entrance effects and boundary layer growth. A transient liquid crystal technique is used to measure detailed heat transfer coefficients (htc) for a rotating, short length, radially outward coolant channel with rib turbulators. Different rib types such as 90 deg, W, and M-shaped ribs are used to roughen the walls to enhance heat transfer. The channel Reynolds number is held constant at 12,000 while the rotation number is increased up to 0.5. Results show that in the near entrance region, the high performance W and M-shaped ribs are just as effective as the simple 90 deg ribs in enhancing heat transfer. The entrance effect in the developing region causes significantly high baseline heat transfer coefficients thus reducing the effective of the ribs to further enhance heat transfer. Rotation causes increase in heat transfer on the trailing side, while the leading side remains relatively constant limiting the decrement in leading side heat transfer. For all rotational cases, the W and M-shaped ribs show significant effect of rotation with large differences between leading and trailing side heat transfer.


2004 ◽  
Vol 126 (1) ◽  
pp. 130-138 ◽  
Author(s):  
Vikrant Saxena ◽  
Hasan Nasir ◽  
Srinath V. Ekkad

A comprehensive investigation of the effect of various tip sealing geometries is presented on the blade tip leakage flow and associated heat transfer of a scaled up HPT turbine blade in a low-speed wind tunnel facility. The linear cascade is made of four blades with the two corner blades acting as guides. The tip section of a HPT first stage rotor blade is used to fabricate the two-dimensional blade. The wind tunnel accommodates an 116 deg turn for the blade cascade. The mainstream Reynolds number based on the axial chord length at cascade exit is 4.83×105. The upstream wake effect is simulated with a spoked wheel wake generator placed upstream of the cascade. A turbulence grid placed even farther upstream generates the required freestream turbulence of 4.8%. The center blade has a tip clearance gap of 1.5625% with respect to the blade span. Static pressure measurements are obtained on the blade surface and the shroud. The effect of crosswise trip strips to reduce leakage flow and associated heat transfer is investigated with strips placed along the leakage flow direction, against the leakage flow and along the chord. Cylindrical pin fins and pitch variation of strips over the tip surface are also investigated. Detailed heat transfer measurements are obtained using a steady-state HSI-based liquid crystal technique. The effect of periodic unsteady wake effect is also investigated by varying the wake Strouhal number from 0. to 0.2, and to 0.4. Results show that the trip strips placed against the leakage flow produce the lowest heat transfer on the tips compared to all the other cases with a reduction between 10–15% compared to the plain tip. Results also show that the pitch of the strips has a small effect on the overall reduction. Cylindrical pins fins and strips along the leakage flow direction do not decrease the heat transfer coefficients and in some cases enhance the heat transfer coefficients by as much as 20%.


Author(s):  
C. Aprea ◽  
A. Greco ◽  
G. P. Vanoli

R22 is the most widely employed HCFC working fluid in vapour compression plant. HCFCs must be replaced within 2020. Major problems arise with the substitution of the working fluids, related to the decrease in performance of the plant. Therefore, extremely accurate design procedures are needed. The relative sizing of each of the components of the plant is crucial for cycle performance. For this reason, the knowledge of the new fluids heat transfer characteristics in condensers and evaporators is required. The local heat transfer coefficients and pressure drop of pure R22 and of the azeotropic mixture R507 (R125-R143a 50%/50% in weight) have been measured during convective boiling. The test section is a smooth horizontal tube made of a with a 6 mm I.D. stainless steel tube, 6 m length, uniformly heated by Joule effect. The effects of heat flux, mass flux and evaporation pressure on the heat transfer coefficients are investigated. The evaporating pressure varies within the range 3 ÷10 bar, the refrigerant mass flux within the range 200 ÷ 1000 kg/m2s, the heat flux within 0 ÷ 44 kW/m2. A comparison have been carried out between the experimental data and those predicted by means of the most credited literature relationships.


Author(s):  
Alexey Vasilievich Ezhov ◽  
Sergey Sergeevich Ivanov ◽  
Aleksandr Bukin ◽  
Vladimir Grigorievich Bukin

The paper presents the results of an experimental study of the effect of oil on the heat transfer rate at boiling of mixed refrigerant R406A. Since the air conditioning system is not a pure refrigerant, but a mixture of oil with a concentration of up to 8%, such an amount of oil affects both hydrodynamics and heat exchange in the evaporators. The experimental work covers the entire range of regime parameters typical for these systems. There is shown the process of changing oil concentration in the pipe, as the working fluid boils, proving that most of the oil pipe does not impair the heat exchange in the course of two-phase flow boiling. Different modes of refrigerant R406A boiling dynamics have been defined, and each mode is given a quantitative assessment in terms of the effects of the oil and explaining of this effect on the fluid flow and heat transfer based on visual observations and the experiment results. The main factor of the effect is the freon-oil foam, which increases the proportion of the wetted surface in the wave and stratified modes and the heat transfer rate to 30%. A comparison of the heat transfer coefficients both in the cross section and along the pipe length has been performed, showing that the maximum change in heat transfer occurs in the upper part of the surface due to developing a dry wall on it and wetting it with freon-oil foam. A comparison of the heat transfer rate of pure refrigerant R406A has been done; the presence of oil in it shows that the effect of oil is complex and ambiguous. Calculation and criterion dependences for calculation of heat transfer coefficients in different modes have been proposed.


Sign in / Sign up

Export Citation Format

Share Document