Improved Noise Characteristics of a Helix-TWT Combined With a Low-Noise Solid-State Amplifier

2004 ◽  
Vol 32 (3) ◽  
pp. 1334-1335 ◽  
Author(s):  
J.H. Joo ◽  
J.J. Choi
Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4694
Author(s):  
Kyeongsik Nam ◽  
Hyungseup Kim ◽  
Yongsu Kwon ◽  
Gyuri Choi ◽  
Taeyup Kim ◽  
...  

Air flow measurements provide significant information required for understanding the characteristics of insect movement. This study proposes a four-channel low-noise readout integrated circuit (IC) in order to measure air flow (air velocity), which can be beneficial to insect biomimetic robot systems that have been studied recently. Instrumentation amplifiers (IAs) with low-noise characteristics in readout ICs are essential because the air flow of an insect’s movement, which is electrically converted using a microelectromechanical systems (MEMS) sensor, generally produces a small signal. The fundamental architecture employed in the readout IC is a three op amp IA, and it accomplishes low-noise characteristics by chopping. Moreover, the readout IC has a four-channel input structure and implements an automatic offset calibration loop (AOCL) for input offset correction. The AOCL based on the binary search logic adjusts the output offset by controlling the input voltage bias generated by the R-2R digital-to-analog converter (DAC). The electrically converted air flow signal is amplified using a three op amp IA, which is passed through a low-pass filter (LPF) for ripple rejection that is generated by chopping, and converted to a digital code by a 12-bit successive approximation register (SAR) analog-to-digital converter (ADC). Furthermore, the readout IC contains a low-dropout (LDO) regulator that enables the supply voltage to drive digital circuits, and a serial peripheral interface (SPI) for digital communication. The readout IC is designed with a 0.18 μm CMOS process and the current consumption is 1.886 mA at 3.3 V supply voltage. The IC has an active area of 6.78 mm2 and input-referred noise (IRN) characteristics of 95.4 nV/√Hz at 1 Hz.


Nanoscale ◽  
2021 ◽  
Author(s):  
Nasim Farajpour ◽  
Lauren Lastra ◽  
Vinay Sharma ◽  
Kevin Freedman

Nanopore sensing is a promising tool with widespread application in single-molecule detection. Borosilicate glass nanopores are a viable alternative to other solid-state nanopores due to low noise and cost-efficient fabrication....


2013 ◽  
Vol 115 (1) ◽  
pp. 137-139
Author(s):  
Qianqian Liu ◽  
Min Yang ◽  
Yi Yao ◽  
Ling Zhao ◽  
Bin Li ◽  
...  
Keyword(s):  

2021 ◽  
Vol 48 (5) ◽  
pp. 0501002
Author(s):  
张宽收 Zhang Kuanshou ◽  
卢华东 Lu Huadong ◽  
李渊骥 Li Yuanji ◽  
冯晋霞 Feng Jinxia

2021 ◽  
Vol 263 (2) ◽  
pp. 4410-4417
Author(s):  
Han Wu ◽  
Chuntai Zheng ◽  
Peng Zhou ◽  
Ryu Fattah ◽  
Xin Zhang ◽  
...  

This paper describes the multi-functional rotor noise and aerodynamics test platform at the Hong Kong University of Science and Technology (HKUST). To investigate the noise characteristics of propellers with aerodynamic flows, the test rig is installed in the 2.5×2 (m) low-speed and low-noise wind tunnel in the Aerodynamic and Acoustic Facility (AAF) at HKUST. The wind tunnel can facilitate flow from 0 to 40 m/s. The test rig is assembled in a turntable on the ceiling of the tunnel wall, which enables the testing range of pitch angle can vary from 0° (axial flow) to 90° (parallel flow), with an accuracy of 0.1°. The noise produced by the rotor is measured by a set of wall-mounted surface microphones. Semi-empirical calibration is conducted to quantify the noise reflection by the tunnel walls. A low-noise struct has been designed and manufactured to locate a set of far-field microphones equipped with nosecone, to improve the quality of acoustic measurement inside the flow. In addition, a synchronized system is developed to conduct the phase-locking Particle Image Velocimetry (PIV) measurement on the rotor, to study the flow pattern to better understand the noise generation mechanism.


Sign in / Sign up

Export Citation Format

Share Document