Study on corrosion failure mechanism of ceramic optocoupler under thermal stress

Author(s):  
Liang Mei ◽  
Daming Yang ◽  
Hong Zhang ◽  
Yuanyuan Xiong
2015 ◽  
Vol 132 ◽  
pp. 260-266 ◽  
Author(s):  
Yang-tao Xu ◽  
Tian-dong Xia ◽  
Wan-ping Wang ◽  
Gui-lan Zhang ◽  
Bao-lin Jia

Author(s):  
Zhifeng Li ◽  
Zhengxiang Wang ◽  
Junke Miao ◽  
Hui Wang

In recent years, the coal chemical industry project which can replace the petrochemical products is an investment hot spot. The Syngas-purification Unit is a main part of the coal chemical industry. Its role is: purify the syngas obtained from the gasification reaction (absorb the hydrogen sulfide and carbon dioxide). Yet, there is no research and the summary about the corrosion, failure mechanism and risk level of this unit. In this paper, the syngas-purification equipment of Sinopec Qilu Corporation were quantified by RBI analysis, and investigated the corrosion of the syngas-purification equipment, and discussed the device typical failure mechanism, and proposed the recommendations of the corrosion and on-line monitoring, etc. In last few years, the production of clean energy and alternative oil chemical products from the new coal chemical projects become of great interest[1]. Because the purification of the syngas is necessary, the syngas-purification unit is one of the main equipment of coal chemical industry. In the country, there is no systematic study or summary about the corrosion, failure mechanism and risk level of the device. The RBI analysis of the Syngas-purification unit is necessary, and has some guiding significance for the routine maintenance and periodic inspection of the device. This paper introduces the corrosion and the typical failure mechanism of Syngas-purification unit followed by the risk assessment results. Then the paper puts forward the suggestion on line monitoring.


Author(s):  
Chen Xuedong ◽  
Ai Zhibin ◽  
Li Rongrong ◽  
Fan Zhichao ◽  
Xu Shuangqing ◽  
...  

For petrochemical pressure vessels subjected to complex media environment, the competition, inhibition, promotion and interference of multiple failure mechanisms have been discussed by several failure case analyses and experimental investigation. The main factors that influence formation of dominant failure mechanism are analyzed and the judgment principles of the dominant failure mechanism are raised in the case of interaction of multiple failure mechanisms. In this paper, relevant mechanisms are also discussed, e.g. intergranular corrosion and intergranular stress corrosion failure mechanisms of austenitic stainless steel, failure mechanisms of austenitic stainless steel when Cl− and alkaline environment exist concurrently and failure mechanism of austenitic stainless steel when medium such as Cl−, CO2, H2S, H2O, etc. exist concurrently.


2015 ◽  
Vol 22 (11) ◽  
pp. 1183-1189 ◽  
Author(s):  
Pan Yi ◽  
Kui Xiao ◽  
Kang-kang Ding ◽  
Xu Wang ◽  
Li-dan Yan ◽  
...  

2006 ◽  
Vol 317-318 ◽  
pp. 553-556 ◽  
Author(s):  
Min Seok Jeon ◽  
Jun Kwang Song ◽  
Eui Jong Lee ◽  
Hee Soo Lee ◽  
Tae Hyung No ◽  
...  

There is an increasing reliability concern of thermal stress-induced failures in multilevel coatings in recent years. This work reports investigations of cracking of NiCr coatings due to thermal cycling. The temperature cycling in accelerated testing was performed in three temperature range of 150, 175 and 200°C. The NiCr coatings were considered to have failed when the sheet resistance changed by 30% relative to an initial value. As the cyclic repetition of thermal shock increased, the sheet resistance of NiCr coatings increased. The Coffin-Manson equation was applied to the failure mechanism of cracking of NiCr coatings and the SEM observation of cracks and delamination in NiCr coatings due to thermal cycling agreed well with the failure mechanism.


2022 ◽  
Vol 905 ◽  
pp. 184-191
Author(s):  
Ting Chun Hu ◽  
Jia Fei Wang ◽  
Yi Yun Xi ◽  
Yu Feng Sun

Aiming at the reliability of thin-film thermocouples applied to turbine blades at high temperatures, combined with high-temperature tests and finite element analysis, this paper studies its failure mechanism and thermal stress under thermal load. Multi-layer thin-film thermocouple samples were prepared on ceramic substrate, and high-temperature tests were carried out under different temperature loads, and the phenomenon of film shedding and cracking was observed using electron microscope. This paper analyzes the failure mechanism of the film sensor based on the function and structure, and uses ANSYS to analyze the thermal stress distribution of the film under high temperature load. Combining several existing theoretical models, this paper analyzes the factors affecting the thermal stress of the film and conducts simulation verification.


2011 ◽  
Vol 2011 (DPC) ◽  
pp. 002465-002480
Author(s):  
Matthew E. Stahley ◽  
John W. Osenbach

Biased-humidity testing is a critical reliability qualification requirement for integrated circuit packages. The benchmark of THB (Temperature Humidity Bias) at 85C/85%RH/bias for 1000 hours is a long duration test, so biased-HAST (biased Highly Accelerated Stress Test) conditions are adopted. Accelerated biased-HAST durations are based on aluminum corrosion failure mechanisms and may not be applicable to other materials such as in flip-chip packages. One such failure mechanism is discussed here. Flip-chip packages with build-up substrates were exposed to biased-humidity at 85C, 110C, or 130C and 85%RH. After 96 hours of 130C/85%RH/bias, failures occurred with signatures ranging from bake-recoverable leakage to shorts. Physical failure analysis revealed copper migration in the substrate build-up dielectric rather than classical CAF (Conductive Anodic Filament) within the substrate core. No copper migration occurred with conditions of 110C/85%RH/bias, 85C/85%RH/bias, or 130C/85%RH/no-bias. Given that the JEDEC biased humidity durations are 96 hours at 130C/85%RH, 264 hours at 110C/85%RH, or 1000 hours at 85C/85%RH, it is concluded that the JEDEC acceleration function is not applicable for this failure mechanism. A failure model is proposed based on humidity induced reduction of the glass transition temperature (Tg) of the build-up dielectric. Bond strength decreases and free volume increases above Tg, and the combination results in the formation of localized channels in the build-up dielectric where electrochemical migration of copper occurs under bias and humidity. Copper migration does not occur for conditions of humidity/bias below Tg, humidity/no-bias above Tg, and no humidity/bias near Tg. This indicates there is likely a threshold in humidity and/or temperature, below which copper migration does not occur. These results further demonstrate that caution must be used when employing accelerated reliability tests, as they may introduce failure mechanisms that would not occur in the field.


2019 ◽  
Vol 10 (3) ◽  
pp. 325-336
Author(s):  
Athanasios Vazdirvanidis ◽  
Sofia Papadopoulou ◽  
Spyros Papaefthymiou ◽  
George Pantazopoulos ◽  
Dionysios Skarmoutsos

Purpose The purpose of this paper is to address the main aspects of ant-nest corrosion failure mechanism of a Cu tube in heating ventilation and air-conditioning (HVAC) installations and analyze the possible root causes through various case studies presented. Design/methodology/approach Failure investigation process includes mainly stereo-, light optical and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy for elemental microanalysis, as the main analytical techniques for material characterization and root-cause analysis. Findings The investigation findings, obtained from corrosion products’ analysis in conjunction to metallographic evaluation in transverse sections, illustrate the principal characteristics (“fingerprints”) of ant-nest (formicary) corrosion mechanism. Originality/value This paper which deals with the presentation of applied failure analysis/case histories’ investigation, summarizing the main aspects of an important and insidious type of Cu corrosion, taken place in HVAC installation systems and, on the other hand, presenting a complementary analysis of the chemical processes involved in the progressive failure mechanism constitutes an integrated approach, aiming to become a concise contribution to this subject.