scholarly journals Experimental investigation on combustion characteristics of flammable refrigerant R290/R1234yf leakage from heat pump system for electric vehicles

2020 ◽  
Vol 7 (4) ◽  
pp. 191478
Author(s):  
Kang Li ◽  
Jingwu Wang ◽  
Shuxian Luo ◽  
Zhenzhen Wang ◽  
Xuejin Zhou ◽  
...  

Concerning the issues regarding driving mileage reduction for electric vehicles (EVs) in cold climates, a heat pump system with low global warming potential refrigerant R290/R1234yf is employed as one of the promising solutions. Different from the widely used mobile refrigerant R134a, R290 and R1234yf are both flammable or explosive. The application of R290/R1234yf in the mobile heat pump system is hindered by unexpected refrigerant leakage with the existence of fire and explosion risk. In this study, the combustion characteristics of R290/R1234yf in a potential leakage process from an air-conditioning heat pump system for EVs were investigated. Firstly, thermodynamic behaviours of R290/R1234yf used in a typical heat pump system were analysed based on a special experimental facility designed for EVs. Then the leakage and combustion characteristics of R290/R1234yf including flame shape, temperature, radiation etc. were obtained by the experimental method under different initial temperature and mass flow rate conditions. It was found that R290/R1234yf leaked is difficult to ignite at low temperatures, while the blow-off phenomenon of the jet flame would occur at high temperature with high leakage mass flow rate. In addition, the results showed that combustion intensity would be enhanced by the leakage mass flow rate between 30 and 60°C. These results could provide guidance for fire detection and rescue system design for new energy vehicles.

Author(s):  
Ook Joong Kim ◽  
Young-Ho Choi ◽  
Seok Ho Yoon

An experimental study on the flow characteristics of electronic expansion valves (EEVs) for heat pump system using carbon dioxide as a refrigerant have been carried out in this study. Many researches and efforts have been made to replace chemical refrigerants like Chloro-Fluoro-Carbon (CFC) and Hydro-Chloro-Fluoro-Carbon (HCFC) with natural refrigerants such as carbon dioxide and apply natural refrigerants to chillers or heat pump systems. In this study, we focused on the development of EEV and 4-way valve among the important components of heat pump system using natural refrigerant. The mass flow rate was measured at various EEV inlet temperature and pressure conditions with respect to several EEV openings operated at a heat pump system which has about 10 kW of cooling capacity. The heat pump system consists of a reciprocating compressor, a gas cooler, an evaporator, an EEV, and a 4-way valve which was developed for this study. The inlet temperature and pressure of an EEV was varied from 5°C to 40°C and from 7 MPa to 10 MPa, respectively. The mass flow rate of carbon dioxide through the EEV ranged from 50 g/s to 120 g/s. The mass flow rate of carbon dioxide around the critical point was affected by the inlet temperature and pressure of EEV, valve opening, and density variation. An empirical mass flow rate correlation of carbon dioxide based on the Buckingham π-theorem was developed in this study, and this correlation predicted experimental data within an average absolute deviation of 4.2%. The correlation can be applied to predict the mass flow rate through EEV used in the heat pump system using carbon dioxide as a refrigerant. And the reliability test of developed 4-way valve was conducted. This 4-way valve showed stable operation in the high pressure condition.


2020 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Ahmad Riaz ◽  
Chao Zhou ◽  
Ruobing Liang ◽  
Jili Zhang

Purpose This paper aims to present a numerical study on the natural convection, which operates either as an evaporator or condenser unit of the heat pump system to pre-cool and pre-heat the ambient fresh air. Design/methodology/approach This study focuses on natural air cooling or heating within the air channel considering the double skin configuration. Particular focus is given to the analysis of airflow and the heat transfer processes in an air channel to cool or heat the ambient fresh air. In this study, the physical model consists of one wall, either heated uniformly or cooled uniformly, whereas the other wall is adiabatic. Findings The results show that the variation of both velocity and temperature is observed as the flow transition occurs at the evaporator or condenser wall. In either case, the temperature rises in the range of 6.3–8.4°C with an increase in mass flow rate from 0.07–0.08 kg/s in the photovoltaic thermal condenser part, while in the photovoltaic thermal evaporator part, the change in mass flow rate from 0.048–0.061 kg/s causes a decrease in temperature from 7.1–4.5°C. Practical implications The solar-assisted photovoltaic thermal heat pump system, in building façade having an air layer application, is feasible for pre-heating and pre-cooling the ambient fresh air and also reduces the energy needed to treat the fresh air. Originality/value The influence of condensing and evaporating temperature under natural convection mode in double skin conformation is considered for pre-heating and pre-cooling of ambient fresh air.


Energies ◽  
2020 ◽  
Vol 13 (12) ◽  
pp. 3133
Author(s):  
Hongzhi Liu ◽  
Katsunori Nagano ◽  
Takao Katsura ◽  
Yue Han

In this study, a heat pump of 10 kW with vapor injection using refrigerant of R410A was developed. A vapor injection pipe connecting a gas–liquid separator at the outlet of the main expansion valve and the suction of a single-stage rotary compressor was designed. The heating performance of this vapor injection heat pump was investigated and analyzed at different compressor frequencies and primary temperatures. The experimental results show that for the heat pump without vapor injection, the heating capacity increased linearly with the compressor frequency, while the heating coefficient of performance (COP) decreased linearly with the compressor frequency for each tested primary temperature. The developed vapor injection technique is able to increase the heat pump system’s heating capacity and heating COP when the injection ratio R falls into the range 0.16–0.17. The refrigerant mass flow rate can be increased in the vapor injection heat pump cycle due to the decreased specific volume of the suction refrigerant. The power consumption of vapor injection heat pump cycle almost remains the same with that of the conventional heat pump cycle because of the increased refrigerant mass flow rate and the decreased compression ratio. Finally, it was found that the developed vapor injection cycle is preferable to decreasing the compressor’s discharge temperature.


2014 ◽  
Vol 960-961 ◽  
pp. 643-647
Author(s):  
Yan Sheng Xu

A stepped capillary tube consisting of two serially connected capillary tubes with different diameters is invented to replace the conventional expansion device. The mass flow rate of refrigerant R410A in stepped capillary tubes with different size were tested. The model of stepped capillary tube is proposed, and its numerical algorithm for tube length and mass flow rate is developed. The experimental results show that the performance comparing between stepped capillary tube system and capillary tube assembly system, the cooling capacity is reduced by 0.3%, the energy efficiency ratio (EER) is equal to each other, the heating capacity is increased by 0.3%, the coefficient of performance (COP) is decreased by 0.3%. That is to say, the performance index of the two kinds of throttle mechanism is almost identical. It indicates that the stepped capillary tube can replace the capillary tube assembly in the R410A heat pump type air conditioner absolutely. The model is validated with experimental data, and the results show that the model can be used for sizing and rating stepped capillary tube.


2019 ◽  
Vol 4 (2) ◽  
Author(s):  
Hamisu A Dandajeh ◽  
Talib O Ahmadu

This paper presents an experimental investigation on the influence of engine speed on the combustion characteristics of a Gardener compression ignition engine fueled with rapeseed methyl esther (RME). The engine has a maximum power of 14.4 kW and maximum speed of 1500 rpm. The experiment was carried out at speeds of 750 and 1250 rpm under loads of 4, 8, 12, 16 and 18 kg. Variations of cylinder pressure with crank angle degrees and cylinder volume have been examined. It was found that RME demonstrated short ignition delay primarily due to its high cetane number and leaner fuel properties (equivalence ratio (φ) = 0.22 at 4kg). An increase in thermal efficiency but decrease in volumetric efficiency was recorded due to increased brake loads. Variations in fuel mass flow rate, air mass flow rate, exhaust gas temperatures and equivalence ratio with respect to brake mean effective pressure at engine speeds of 750 and 1250 rpm were also demonstrated in this paper. Higher engine speed of 1250 rpm resulted in higher fuel and air mass flow rates, exhaust temperature, brake power and equivalent ratio but lower volumetric efficiency. Keywords— combustion characteristics, engine performance, engine speed, rapeseed methyl Esther


2014 ◽  
Vol 592-594 ◽  
pp. 2416-2421
Author(s):  
R.N. Kokila ◽  
S. Rajakumar

The main objective of this paper is to analyze the thermal performance of direct expansion solar assisted heat pump DX-SAHP(A) by numerical simulation in MATLAB and comparing it with the thermal performance of DX-SAHP(B) which has an optimized collector area and mass flow rate. Optimization is performed for high exergy efficiency using Particle Swarm Optimization (PSO) and Artificial Bee Colony (ABC) optimization technique. The flat plate collector of solar water heater is used as the evaporator with refrigerant (R22).With the optimized value of mass flow rate as 0.055 kg/sec, width as 0.03 m and diameter of riser tubes as 0.021 m the performance of the optimized system has a maximum COP of 6.85 which is greater than the COP of DX-SAHP(A) and the final water temperature of is obtained 100 minutes earlier in the optimized system i.e. DX-SAHP(B) with compressor work less than the system A


Author(s):  
Kang Li ◽  
Jun Yu ◽  
Rong Yu ◽  
Lin Su ◽  
Yidong Fang ◽  
...  

Abstract Utilizing the heat from air source with heat pump system in electric vehicles shows a significant advantage from thermoelectric heat source for heat supply in cold climate. It could improve the driving range of electric vehicles considerably in winter and replace the positive temperature coefficient (PTC) heater with an acceptable cost and reliability. In this work, a newly designed heat pump system was first introduced with less components and cost. Second, experiments were conducted to investigate its cooling performance, and subsequent heating performance from −10 to 10 °C. The typical heat transfer and flow characteristics of refrigerant were recorded, and the behavior of each component including compressor, evaporator, condenser, and outside heat exchanger were analyzed and interpreted. The results showed that the heating and cooling performance of the new heat pump system could almost remain the same with traditional air-conditioning system in automobile and surely satisfy with the heat requirement of electric vehicles. In the heating mode, the maximum heating capacity increases by 13% at 400 m3/h air volume from 300 m3/h at the ambient temperature −10 °C, while the outlet air temperature decreases by 4–6%. In addition, using a heat pump system showed an increase in the driving range of electric vehicles by 25–31% as compared to PTC heaters.


Author(s):  
Michael J. Kazmierczak ◽  
Abhishek Gupta

Experiments were performed on a heat exchanger equipped with multiple thermoelectric (TE) modules. The TE-HX serves as the basic system component in a simple hydronic modular Peltier heat pump system designed to provide chilled or hot water for domestic use (or supplementary building climate control) of small residences [1]. The present work focuses on the detailed convection analysis inside the TE-HX component when 10 thermoelectric modules are utilized. The local heat transfer coefficient at different points along the channel are measured at steady-state, first, when a continuous heater is installed and then when replaced with 10 TE modules. The experimental heat transfer coefficients obtained are compared with available empirical correlations for “transition” (3000 < ReDh < 7000) turbulent flow inside the channel with fair-to-good results. Next, the resulting coefficient-of-performance of the TE heat pump system is measured with its value depending both on system input power and water flow rate. Testing showed that performance degradation, i.e. reduced COPs, occurred when operated at higher power levels but remains satisfactory for up to 688 Watts with higher flow rate.