A NEW SEMI-EMPIRICAL AMBIENT TO EFFECTIVE DOSE CONVERSION MODEL FOR THE PREDICTIVE CODE FOR AIRCREW RADIATION EXPOSURE (PCAIRE)

2015 ◽  
Vol 172 (4) ◽  
pp. 333-340 ◽  
Author(s):  
T. Dumouchel ◽  
M. McCall ◽  
F. Lemay ◽  
L. Bennett ◽  
B. Lewis ◽  
...  
2008 ◽  
Vol 47 (04) ◽  
pp. 175-177 ◽  
Author(s):  
J. Dolezal

SummaryAim: To assess a radiation exposure and the quality of radiation protection concerning a nuclear medicine staff at our department as a six-year retrospective study. Therapeutic radionuclides such as 131I, 153Sm, 186Re, 32P, 90Y and diagnostic ones as a 99mTc, 201Tl, 67Ga, 111In were used. Material, method: The effective dose was evaluated in the period of 2001–2006 for nuclear medicine physicians (n = 5), technologists (n = 9) and radiopharmacists (n = 2). A personnel film dosimeter and thermoluminescent ring dosimeter for measuring (1-month periods) the personal dose equivalent Hp(10) and Hp(0,07) were used by nuclear medicine workers. The wearing of dosimeters was obligatory within the framework of a nationwide service for personal dosimetry. The total administered activity of all radionuclides during these six years at our department was 17,779 GBq (99mTc 14 708 GBq, 131I 2490 GBq, others 581 GBq). The administered activity of 99mTc was similar, but the administered activity of 131I in 2006 increased by 200%, as compared with the year 2001. Results: The mean and one standard deviation (SD) of the personal annual effective dose (mSv) for nuclear medicine physicians was 1.9 ± 0.6, 1.8 ± 0.8, 1.2 ± 0.8, 1.4 ± 0.8, 1.3 ± 0.6, 0.8 ± 0.4 and for nuclear medicine technologists was 1.9 ± 0.8, 1.7 ± 1.4, 1.0 ± 1.0, 1.1 ± 1.2, 0.9 ± 0.4 and 0.7 ± 0.2 in 2001, 2002, 2003, 2004, 2005 and 2006, respectively. The mean (n = 2, estimate of SD makes little sense) of the personal annual effective dose (mSv) for radiopharmacists was 3.2, 1.8, 0.6, 1.3, 0.6 and 0.3. Although the administered activity of 131I increased, the mean personal effective dose per year decreased during the six years. Conclusion: In all three professional groups of nuclear medicine workers a decreasing radiation exposure was found, although the administered activity of 131I increased during this six-year period. Our observations suggest successful radiation protection measures at our department.


Author(s):  
Seung Wan Hong ◽  
Tae Won Kim ◽  
Jae Hun Kim

Abstract Physicians and nurses stand with their back towards the C-arm fluoroscope when using the computer, taking things out of closets and preparing drugs for injection or instruments for intervention. This study was conducted to investigate the relationship between the type of lead apron and radiation exposure to the backs of physicians and nurses while using C-arm fluoroscopy. We compared radiation exposure to the back in the three groups: no lead apron (group C), front coverage type (group F) and wrap-around type (group W). The other wrap-around type apron was put on the bed instead of on a patient. We ran C-arm fluoroscopy 40 times for each measurement. We collected the air kerma (AK), exposure time (ET) and effective dose (ED) of the bedside table, upper part and lower part of apron. We measured these variables 30 times for each location. In group F, ED of the upper part was the highest (p < 0.001). ED of the lower part in group C and F was higher than that in group W (p = 0.012). The radiation exposure with a front coverage type apron is higher than that of the wrap-around type and even no apron at the neck or thyroid. For reducing radiation exposure to the back of physician or nurse, the wrap-around type apron is recommended. This type of apron can reduce radiation to the back when the physician turns away from the patient or C-arm fluoroscopy.


2021 ◽  
Vol 66 (6) ◽  
pp. 102-110
Author(s):  
A. Molokanov ◽  
B. Kukhta ◽  
E. Maksimova

Purpose: Harmonization and improvement of the system for regulating the internal radiation exposure of workers and the basic requirements for ensuring radiation safety with international requirements and recommendations. Material and methods: Issues related to the development of approaches to regulation and monitoring of workers for internal radiation exposure in the process of evolution of the ICRP recommendations and the national radiation safety standards, are considered. The subject of analysis is the standardized values: dose limits for workers and permissible levels as well as directly related methods of monitoring of workers for internal radiation exposure, whose purpose is to determine the degree of compliance with the principles of radiation safety and regulatory requirements, including non-exceeding the basic dose limits and permissible levels. The permissible levels of inhalation intake of insoluble compounds (dioxide) of plutonium-239 are considered as a numerical example. Results: Based on the analysis of approaches to the regulation and monitoring of workers for internal radiation exposure for the period from 1959 to 2019, it is shown that a qualitative change in the approach occurred in the 1990s. It was due to a decrease in the number of standardized values by introducing a single dose limit for all types of exposure: the effective dose E, which takes into account the different sensitivity of organs and tissues for stochastic radiation effects (WT), using the previously accepted concepts of the equivalent dose H and groups of critical organs. From the analysis it follows that the committed effective dose is a linear transformation of the intake, linking these two quantities by the dose coefficient, which does not depend on the time during which the intake occurred, and reflects certain exposure conditions of the radionuclide intake (intake routes, parameters of aerosols and type of radionuclide compounds). It was also shown that the reference value of the function z(t) linking the measured value of activity in an organ (tissue) or in excretion products with the committed effective dose for a reference person, which is introduced for the first time in the publications of the ICRP OIR 2015-2019, makes it possible to standardize the method of measuring the normalized value of the effective dose. Based on the comparison of the predicted values of the lung and daily urine excretion activities following constant chronic inhalation intake of insoluble plutonium compounds at a rate equal annual limit of intake (ALI) during the period of occupational activity 50 years it was shown that the modern biokinetic models give a slightly lower level (on average 2 times) of the lungs exposure compared to the models of the previous generation and a proportionally lower level (on average 1.4 times) of plutonium urine excretion for the standard type of insoluble plutonium compounds S. However, for the specially defined insoluble plutonium compound, PuO2, the level of plutonium urine excretion differs significantly downward (on average 11.5 times) compared to the models of the previous generation. Conclusion: With the practical implementation of new ICRP OIR models, in particular for PuO2 compounds, additional studies should be carried out on the behavior of insoluble industrial plutonium compounds in the human body. Besides, additional possibilities should be used to determine the intake of plutonium by measuring in the human body the radionuclide Am-241, which is the Pu-241 daughter. To determine the plutonium urine excretion, the most sensitive measurement techniques should be used, having a decision threshold about fractions of mBq in a daily urine for S-type compounds and an order of magnitude lower for PuO2 compounds. This may require the development and implementation in monitoring practice the plutonium-DTPA Biokinetic Model.


2019 ◽  
Vol 186 (2-3) ◽  
pp. 386-390
Author(s):  
V Dufek ◽  
H Zackova ◽  
L Kotik ◽  
I Horakova

Abstract About 26 000 patients are treated per year with radiotherapy for non-malignant diseases in the Czech Republic. Approximately 75% of them are treated on X-ray therapy units and most of these patients undergo radiotherapy of heel spurs. The evaluation of radiation exposure of these patients was based on measured organ doses and on data from clinical practice. Collective effective doses for particular diagnoses were calculated in order to compare doses resulting from different diagnoses treated on X-ray therapy units. The collective effective dose from radiotherapy of heel spurs in the Czech Republic in 2013 was evaluated to 77 manSv. It represents 25.6% of the total collective effective dose for all diagnoses of radiotherapy for non-malignant diseases treated on X-ray therapy units.


2020 ◽  
Vol 189 (1) ◽  
pp. 35-47
Author(s):  
Anna Bågenholm ◽  
Pål Løvhaugen ◽  
Rune Sundset ◽  
Tor Ingebrigtsen

Abstract This audit describes ionizing and non-ionizing diagnostic imaging at a regional trauma centre. All 144 patients (males 79.2%, median age 31 years) met with trauma team activation from 1 January 2015 to 31 December 2015 were included. We used data from electronic health records to identify all diagnostic imaging and report radiation exposure as dose area product (DAP) for conventional radiography (X-ray) and dose length product (DLP) and effective dose for CT. During hospitalization, 134 (93.1%) underwent X-ray, 122 (84.7%) CT, 92 (63.9%) focused assessment with sonography for trauma (FAST), 14 (9.7%) ultrasound (FAST excluded) and 32 (22.2%) magnetic resonance imaging. One hundred and sixteen (80.5%) underwent CT examinations during trauma admissions, and 73 of 144 (50.7%) standardized whole body CT (SWBCT). DAP values were below national reference levels. Median DLP and effective dose were 2396 mGycm and 20.42 mSv for all CT examinations, and 2461 mGycm (national diagnostic reference level 2400) and 22.29 mSv for a SWBCT.


2020 ◽  
Vol 189 (4) ◽  
pp. 466-474
Author(s):  
Wiam Elshami ◽  
Mohamed Abuzaid ◽  
Antti Pekkarinen ◽  
Mika Kortesniemi

Abstract Purpose Occupational radiation exposure for medical workers in radiology and cardiology was analyzed in nine hospitals in the UAE between 2002 and 2016. The purpose of the study was to determine the time trend and the differences in occupational radiation exposure among worker groups and hospitals in the country. Methods Readings of 5700 thermoluminescence dosimeters (TLDs) were obtained from 1011 medical workers and grouped into 5 worker groups (radiographers, diagnostic radiologists, nurses, cardiologists and physicians). Results The mean annual effective dose was from 0.38 to 0.62 mSv per worker. Even though an increase in the collective effective dose has been noticed during the study period, no significant time trend was observed in the mean effective dose. Furthermore, cardiologists received higher mean and maximum effective doses than the other worker groups. Conclusion The annual effective doses were below the limits set by national legislation and international standards, and for the average worker, the likelihood of high exposure is small. However, improvements in radiation protection practices could be implemented to reduce occupational radiation dose to cardiologists, who were the most exposed worker group in this study.


2014 ◽  
Vol 8 (9-10) ◽  
pp. 347 ◽  
Author(s):  
Andrea G Lantz ◽  
Padraic O'Malley ◽  
Michael Ordon ◽  
Jason Y Lee

Introduction: Percutaneous nephrolithotomy (PCNL) may be associated with significant ionizing radiation exposure for patients and operating room staff. Endoscopic-guided PCNL (ePCNL) is a technique that may be associated with less radiation exposure. This study examines ePCNL-related radiation exposure (fluoroscopytime, effective dose) and investigates variables that may predict increased exposure.Methods: A retrospective review of all consecutive ePCNLs performed at our institution, by a single surgeon, was conducted between November 2011 and November 2013. Patient demographics, stone characteristics and perioperative details were recorded, including radiation exposure. Pearson and Spearman correlation were used to assess variables correlated with radiation exposure.Results: In total, 55 ePCNL cases were included in the study. The mean age was 60 ± 15 years, mean body mass index (BMI) 30.0 ± 6.4 kg/m2 and mean stone size 3.2 × 2.1 cm. Seven cases (13%) involved complete staghorn stones, and 69% involved supracostal punctures. The mean fluoroscopy time was 3.4 ± 2.3 minutes, mean ED 2.4 ± 1.9 mSv. The treatment success rate, assessed 1-week postoperatively, was 87.3% and 7.3% of cases required ancillary procedures. The overall complication rate was 29%, but only 3 cases (5.5%) were Clavien ≥3. Longer fluoroscopy time correlated with increased stone size (p < 0.01), longer operative time (p < 0.01) and lower treatment success rates (p < 0.01); higher effective dose correlated with longer fluoroscopy time (p < 0.01) and increased skin-to-stone distance (p < 0.01). BMI did not correlate with fluoroscopy time or effective dose.Conclusions: Outcomes of ePCNL are comparable to traditional PCNL techniques and may be associated with lower radiation exposure, particularly beneficial for patients with higher BMI.


Radiology ◽  
2008 ◽  
Vol 249 (3) ◽  
pp. 1002-1009 ◽  
Author(s):  
Valerie L. Ward ◽  
Keith J. Strauss ◽  
Carol E. Barnewolt ◽  
David Zurakowski ◽  
Vaidehi Venkatakrishnan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document