scholarly journals Assessing radiation exposure during endoscopic-guided percutaneous nephrolithotomy

2014 ◽  
Vol 8 (9-10) ◽  
pp. 347 ◽  
Author(s):  
Andrea G Lantz ◽  
Padraic O'Malley ◽  
Michael Ordon ◽  
Jason Y Lee

Introduction: Percutaneous nephrolithotomy (PCNL) may be associated with significant ionizing radiation exposure for patients and operating room staff. Endoscopic-guided PCNL (ePCNL) is a technique that may be associated with less radiation exposure. This study examines ePCNL-related radiation exposure (fluoroscopytime, effective dose) and investigates variables that may predict increased exposure.Methods: A retrospective review of all consecutive ePCNLs performed at our institution, by a single surgeon, was conducted between November 2011 and November 2013. Patient demographics, stone characteristics and perioperative details were recorded, including radiation exposure. Pearson and Spearman correlation were used to assess variables correlated with radiation exposure.Results: In total, 55 ePCNL cases were included in the study. The mean age was 60 ± 15 years, mean body mass index (BMI) 30.0 ± 6.4 kg/m2 and mean stone size 3.2 × 2.1 cm. Seven cases (13%) involved complete staghorn stones, and 69% involved supracostal punctures. The mean fluoroscopy time was 3.4 ± 2.3 minutes, mean ED 2.4 ± 1.9 mSv. The treatment success rate, assessed 1-week postoperatively, was 87.3% and 7.3% of cases required ancillary procedures. The overall complication rate was 29%, but only 3 cases (5.5%) were Clavien ≥3. Longer fluoroscopy time correlated with increased stone size (p < 0.01), longer operative time (p < 0.01) and lower treatment success rates (p < 0.01); higher effective dose correlated with longer fluoroscopy time (p < 0.01) and increased skin-to-stone distance (p < 0.01). BMI did not correlate with fluoroscopy time or effective dose.Conclusions: Outcomes of ePCNL are comparable to traditional PCNL techniques and may be associated with lower radiation exposure, particularly beneficial for patients with higher BMI.

2008 ◽  
Vol 47 (04) ◽  
pp. 175-177 ◽  
Author(s):  
J. Dolezal

SummaryAim: To assess a radiation exposure and the quality of radiation protection concerning a nuclear medicine staff at our department as a six-year retrospective study. Therapeutic radionuclides such as 131I, 153Sm, 186Re, 32P, 90Y and diagnostic ones as a 99mTc, 201Tl, 67Ga, 111In were used. Material, method: The effective dose was evaluated in the period of 2001–2006 for nuclear medicine physicians (n = 5), technologists (n = 9) and radiopharmacists (n = 2). A personnel film dosimeter and thermoluminescent ring dosimeter for measuring (1-month periods) the personal dose equivalent Hp(10) and Hp(0,07) were used by nuclear medicine workers. The wearing of dosimeters was obligatory within the framework of a nationwide service for personal dosimetry. The total administered activity of all radionuclides during these six years at our department was 17,779 GBq (99mTc 14 708 GBq, 131I 2490 GBq, others 581 GBq). The administered activity of 99mTc was similar, but the administered activity of 131I in 2006 increased by 200%, as compared with the year 2001. Results: The mean and one standard deviation (SD) of the personal annual effective dose (mSv) for nuclear medicine physicians was 1.9 ± 0.6, 1.8 ± 0.8, 1.2 ± 0.8, 1.4 ± 0.8, 1.3 ± 0.6, 0.8 ± 0.4 and for nuclear medicine technologists was 1.9 ± 0.8, 1.7 ± 1.4, 1.0 ± 1.0, 1.1 ± 1.2, 0.9 ± 0.4 and 0.7 ± 0.2 in 2001, 2002, 2003, 2004, 2005 and 2006, respectively. The mean (n = 2, estimate of SD makes little sense) of the personal annual effective dose (mSv) for radiopharmacists was 3.2, 1.8, 0.6, 1.3, 0.6 and 0.3. Although the administered activity of 131I increased, the mean personal effective dose per year decreased during the six years. Conclusion: In all three professional groups of nuclear medicine workers a decreasing radiation exposure was found, although the administered activity of 131I increased during this six-year period. Our observations suggest successful radiation protection measures at our department.


2019 ◽  
Vol 25 (1) ◽  
Author(s):  
Elsayed M. Salih ◽  
Ibrahim Elsotohi ◽  
Hisham Elhelaly ◽  
Mohamed Elsalhy ◽  
Mourad M. Mourad

Abstract Background The goal for using smaller caliber instruments in PNL was to reduce the access-related complications and to decrease morbidity. The objective of this study was to evaluate the safety and efficacy of Chinese minimally invasive percutaneous nephrolithotomy (MIPNL) in the treatment of renal stones ≤ 20 mm. Results Sixty-seven patients completed the study protocol. The mean age was 41.10 ± 13.99 years (range 18–68 years). There were 43 (64%) male and 24 (36%) females. The mean stone size was ranged from 78.5 to 439.6 mm2 (mean ± SD 172.48 ± 69.54 mm2). The overall SFR was (82%). Twelve (18%) needed post-MIPNL auxiliary procedure, in the form of second MIPNL in 3 (4.5%) cases, SWL in 7 (10%), and RIRS in 2 (3%) cases. The intraoperative complication was present in four patients (5%) include bleeding necessitate blood transfusion in one patient (1.5%) and renal collecting system perforation 3 (4.5%). The postoperative complication was urine leakage 5 (7.5) and fever in 6 (9%) of patients. Conclusion Chinese MIPNL is safe and effective method for treatment of renal stone ≤ 20 mm size with satisfactory SFR and low complication rate when SWL failed or contraindicated. It is considered a feasible treatment alternative to standard PNL, in the absence of flexible URS or miniature nephroscope.


Author(s):  
Andrew G. Yun ◽  
Marilena Qutami ◽  
Kory B. Dylan Pasko

AbstractPreoperative templating for total hip arthroplasty (THA) is fraught with uncertainty. Specifically, the conventional measurement of the lesser trochanter to the center (LTC) of the femoral head used in preoperative planning is easily measured on a template but not measurable intraoperatively. The purpose of this study was to examine the utility of a novel measurement that is reproducible both on templating and in surgery as a more accurate and practical guide. We retrospectively reviewed 201 patients with a history of osteoarthritis who underwent primary THA. For preoperative templating, the distance from the top of the lesser trochanter to the equator (LeTE) of the femoral head was measured on a calibrated digital radiograph with a neutral pelvis. This measurement was used intraoperatively to guide the choice of the trial neck and head. As with any templating technique, the goal was to construct a stable, impingement-free THA with equivalent leg lengths and hip offset. In evaluating this novel templating technique, the primary outcomes measured were the number of trial reductions and the amount of fluoroscopic time, exposures, and radiation required to obtain a balanced THA reconstruction. Using the LeTE measurement, the mean number of trial reductions was 1.21, the mean number of intraoperative fluoroscopy images taken was 2.63, the mean dose of radiation exposure from fluoroscopy was 0.02 mGy, and the mean fluoroscopy time per procedure was 0.6 seconds. In hips templated with the conventional LTC prior to the LeTE, the mean fluoroscopy time was 0.9 seconds. There was a statistically significant difference in fluoroscopy time (p < 0.001). The LeTE is a reproducible measurement that transfers reliably from digital templating to surgery. This novel preoperative templating metric reduces the fluoroscopy time and consequent radiation exposure to the surgical team and may minimize the number of trial reductions.


2020 ◽  
Vol 19 (5) ◽  
pp. 495-501 ◽  
Author(s):  
Joshua H Weinberg ◽  
Ahmad Sweid ◽  
Omaditya Khanna ◽  
Nikolaos Mouchtouris ◽  
Ashlee Asada ◽  
...  

Abstract BACKGROUND Distal transradial catheterization in the anatomic snuffbox is an alternate route of access that has started to gain consideration for neuroendovascular procedures. OBJECTIVE To assess the feasibility and outcomes and present our institution's experience in performing neuroendovascular procedures via distal transradial access (dTRA). METHODS We conducted a retrospective analysis and identified 120 patients who underwent consecutive neuroendovascular procedures via dTRA in the anatomic snuffbox. Data collection was performed on indication for procedure, sheath size, number of vessels selectively catheterized, fluoroscopy time, procedure duration, radiation exposure, conversion to femoral approach, access site complication, and procedure success. RESULTS Of 120 patients with an average age of 54.7 yr ± 14.7, 73 (60.8%) underwent diagnostic angiograms, 38 (31.7%) underwent follow-up angiograms, and 9 (7.5%) underwent therapeutic procedures. The overall mean number of vessels catheterized was 2.5 ± 0.1 per procedure, the mean procedure time was 68.3 min ± 43.4, the mean fluoroscopy time was 10.8 min ± 7.6, the mean contrast dose was 70.6 mL ± 39.1, and the mean radiation exposure was 27 672.2 mGycm2 ± 42 728.4. Successfully completed therapeutic procedures included aneurysm 1 (0.8%), arteriovenous malformation (AVM)/arteriovenous fistula/carotid cavernous fistula 7 (5.8%), and 1 (0.8%) other treatment. Three patients (2.5%) required adjunct transfemoral endovenous access for AVM embolization. Two minor complications (1.67%) were a local wrist hematoma and a radial artery vasospasm without any sequelae. CONCLUSION Distal radial artery catheterization in the anatomic snuffbox is a safe and effective access site to perform neuroendovascular procedures. Complications and conversion rate are low making it a safe alternative.


2015 ◽  
Vol 143 (15) ◽  
pp. 3203-3210 ◽  
Author(s):  
H. BISHARA ◽  
D. GOLDBLATT ◽  
E. RORMAN ◽  
Z. MOR

SUMMARYThe incidence of tuberculosis (TB) in native ethnic minorities remains high in developed countries. Arabs, the major ethnic minority in Israel, comprise 21% of its population. This retrospective study compared TB incidence, demographic, clinical, laboratory, genotyping characteristics and treatment outcomes in all Israeli-born citizens diagnosed with TB between 1999 and 2011 by ethnicity, i.e. Israeli-born Arabs (IA) and Jews (IJ). A total of 831 Israeli-born TB patients were reported. Of those, there were 530 (64%) IJ and 301 (36%) IA, with an average annual TB rate of 1·1 and 1·6 cases/100 000 population, respectively, lower than the national average (7·0 cases/100 000 population). TB rates in IA and IJ declined and converged to 1 case/100 000 residents. IA TB patients were more likely to be older, have more pulmonary TB and have lower treatment success rates than IJ. Older age and HIV co-infection, but not ethnicity, were predictive of non-success in TB treatment. Ten mixed IA–IJ clades were detected by spoligotyping and three mixed IA–IJ clusters were identified by MIRU-VNTR typing. Only one IA–IJ couple recalled mutual contact. In conclusion, TB rate in IA was higher than in IJ, but declined and converged in both to 1 case/100 000. Treatment success was high in both groups, and was unrelated to ethnicity.


2020 ◽  
Vol 189 (4) ◽  
pp. 466-474
Author(s):  
Wiam Elshami ◽  
Mohamed Abuzaid ◽  
Antti Pekkarinen ◽  
Mika Kortesniemi

Abstract Purpose Occupational radiation exposure for medical workers in radiology and cardiology was analyzed in nine hospitals in the UAE between 2002 and 2016. The purpose of the study was to determine the time trend and the differences in occupational radiation exposure among worker groups and hospitals in the country. Methods Readings of 5700 thermoluminescence dosimeters (TLDs) were obtained from 1011 medical workers and grouped into 5 worker groups (radiographers, diagnostic radiologists, nurses, cardiologists and physicians). Results The mean annual effective dose was from 0.38 to 0.62 mSv per worker. Even though an increase in the collective effective dose has been noticed during the study period, no significant time trend was observed in the mean effective dose. Furthermore, cardiologists received higher mean and maximum effective doses than the other worker groups. Conclusion The annual effective doses were below the limits set by national legislation and international standards, and for the average worker, the likelihood of high exposure is small. However, improvements in radiation protection practices could be implemented to reduce occupational radiation dose to cardiologists, who were the most exposed worker group in this study.


SICOT-J ◽  
2020 ◽  
Vol 6 ◽  
pp. 6
Author(s):  
Yuta Jinnai ◽  
Tomonori Baba ◽  
Xu Zhuang ◽  
Hiroki Tanabe ◽  
Sammy Banno ◽  
...  

Introduction: Intraoperative fluoroscopy can be easily used because patients are placed in the supine position during total hip arthroplasty via direct anterior approach (DAA-THA) to reduce complications. However, the cumulative level of radiation exposure by intraoperative fluoroscopy increases as the annual number of cases increases, increasing the risk of influencing the health of both the patients and medical workers. The objective of the study was to compare the radiation exposure time of DAA-THA with osteosynthesis and to determine if the level of radiation exposure exceeded safety limits. Material and methods: DAA-THA was performed in 313 patients between January 2016 and July 2018 and 60 patients with proximal femoral fracture were treated with osteosynthesis. The intraoperative fluoroscopy time was retrospectively surveyed and compared between these two groups. A total of eight surgeons operated DAA-THA employing the same procedure using a traction table. A total of nine surgeons operated osteosynthesis and fluoroscopy was appropriately used during reduction and implant insertion. Results: The mean operative time of DAA-THA was 103.3 min and that of osteosynthesis was 83.3 min, showing a significant difference (p < 0.05). The mean intraoperative fluoroscopy time was 0.83 min (SD ± 0.68) in DAA-THA and 8.91 min (SD ± 8.34) in osteosynthesis showing a significant difference (p < 0.05). Conclusions: The intraoperative exposure level was significantly lower and the fluoroscopy time was significantly shorter in DAA-THA than in osteosynthesis for proximal femoral fracture. It was clarified that the annual cumulative radiation exposure level in DAA-THA does not exceed the tissue dose limit.


Vascular ◽  
2019 ◽  
Vol 27 (6) ◽  
pp. 617-622 ◽  
Author(s):  
Jesse Chait ◽  
Nikolay Davis ◽  
Yuriy Ostrozhynskyy ◽  
Sareh Rajaee ◽  
Natalie Marks ◽  
...  

Objective Fluoroscopic-guided interventions have become a major part of the modern vascular surgeon’s practice. Imaging is typically required to safely and effectively perform both simple and complex endovascular interventions. With an ever-increasing volume of fluoroscopic-guided interventions being performed each year, the minimization of harmful radiation exposure has become of paramount concern for both patients and providers. The purpose of this study was to identify the extent of radiation exposure associated with venography and iliac vein stenting, an intervention utilized in the management of chronic venous insufficiency. Methods This was a single-center, retrospective analysis of 40 venograms performed on 29 unique patients over a three-month period. Patients with signs and symptoms of chronic venous insufficiency who failed conservative therapy underwent evaluation of the vena cava and iliofemoral veins with venography and intravascular ultrasound. Stent placement was performed if a >50% cross-sectional area or diameter reduction was identified via intravascular ultrasound. All patients were found to have non-thrombotic iliac vein lesions. All patients wore two individual film badge dosimeters – one on their chest and the other on the abdomen. The same mobile C-arm system was used for all interventions. Results There were 15 males and 14 females, with an average age of 70.6 years old (SD ± 9.5; range 53–89) and a mean body mass index of 33.9 kg/m2. Sixteen limbs had C6 disease, 10 had C4 disease, and 14 had C3 disease. Thirty-eight of the 40 procedures resulted in stent placement, with an average of 1.13 stents placed per intervention. The average fluoroscopy time was 76.5 s (SD ± 36.9; range 7.8–209.5), and the mean cumulative air kerma was 1.08 mGy (SD ± 0.55; range 0.362–2.24). Average cumulative air kerma was higher in procedures resulting >1 stent placement compared to those with placement of ≤1 stent (1.44 vs. 1.02 mGy; p = 0.04). Fluoroscopy time was also higher in procedures with >1 stent placed (120.1 vs. 68.8 s; p = 0.0004). The mean deep dose equivalent per procedure from the patient-worn abdominal badge was 0.221 mSv. Conclusion With the adjunctive use of intravascular ultrasound, iliac vein stenting can be safely and effectively performed with very low utilization of fluoroscopy, and therefore radiation exposure can be minimized for both patients and surgeons. Placement of >1 iliac vein stent resulted in higher cumulative air kerma and fluoroscopy time.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
V Varnavas ◽  
K De Schouwer ◽  
JP Abugattas ◽  
M Wolf ◽  
Y De Greef ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Cardiac computed tomography (CCT) is an essential tool for an efficient ablation for atrial fibrillation. 3D mapping guided ablation could also deliver sufficient results in the setting of cryoballoon ablation (CBA) with additional advantages regarding total patient radiation exposure, fluoroscopy and procedural time. Purpose To compare the 3D mapping with the Achieve® catheter versus the CCT on the procedural characteristics and acute outcome during CBA. Methods Consecutive patients who underwent CBA with the second-generation cryoballoon (CB) were retrospectively enrolled from a single centre registry. Baseline and procedural characteristics of patients with pre-procedural CCT (CT-Group) were compared to those with peri-procedural 3D mapping (Ensite PrecisionTM ) with the 1st generation Achieve® catheter (3D-Group). Results A total of 696 patients were enrolled, 327 (47%) in the CT-Group and 369 (53%) in the 3D-Group. Baseline characteristics were comparable between the two groups. Similar pulmonary vein (PV) anatomical variations were identified in both groups and all PVs were acutely isolated. The mean CB temperature (T) at 60s, the nadir T, the time to PV isolation, the T of isolation and the mean thaw time did not differ significantly. However, the total procedural and fluoroscopy time were significantly shorter as well as the dose area product was significantly less  in the 3D-Group. Conclusion 3D mapping guided CBA using the Achieve® catheter is associated with significantly shorter fluoroscopy and procedural time and less patient radiation exposure. The anatomical acquisition of the PVs and the acute ablation outcome is non inferior to the CCT guided CBA. Procedural characteristics CT-Group n = 327 3D- Groupn = 369 p-value Paroxysmal AF 214 244 0.87 Total procedure time (min) 73.3 ± 23.1 65.1 ± 18.9 &lt; 0.01 Fluoroscopy time (min) 14.9 ± 7.7 12.6 ± 7 0.02 DAP (Gy·cm2) 5924 ± 4991 4890 ± 3790 0.04 LCPV 37 41 1.00 RMPV 20 21 0.87 Mean T at 60s(oC) -41.9 ± 8.5 -40.6 ± 10.7 0.10 Mean nadir T(oC) -49.5 ± 6.4 -48.4 ± 7.8 0.18 Mean PVI time(s) 42.4 ± 26.3 38.1 ± 24.3 0.11 Mean PVI temperature(oC) -33.4 ± 11.6 -31.1 ± 22 0.16 Mean thaws time(s) 51.5 ± 20.5 51.8 ± 20.3 0.85


Sign in / Sign up

Export Citation Format

Share Document