The Accuracy of Saccadic and Perceptual Decisions in Visual Search

Perception ◽  
1997 ◽  
Vol 26 (1_suppl) ◽  
pp. 133-133
Author(s):  
M P Eckstein ◽  
B B Beutter ◽  
L S Stone

Saccadic eye movements during search for a target embedded in noise are suboptimally guided by information about target location (Eckstein et al, 1997, paper presented at ARVO). Our goal was to compare the spatial information used to guide the saccades with that used for the perceptual decision. Three observers were asked to determine the location of a bright disk (diameter 21 min arc) in white noise (signal-to-noise ratio 4.2) from among ten possible locations evenly spaced at 5.9 deg eccentricity. In the first of four conditions, observers used natural eye movements. In the three remaining conditions, observers fixated a central cross at all times. The fixation conditions consisted of three different presentation times (100, 200, 300 ms), each followed by a mask. Eye-position data were collected with a resolution of ∼0.2 deg. In the natural viewing condition, we measured the accuracy with respect to the target and the latency of the first saccade. In the fixation conditions, we discarded trials in which observers broke fixation. Perceptual performance was computed for all conditions. Averaged across observers, the first saccade was correct (closest to the target location) for 56±7 (SD) % of trials (chance 10%) and occurred after a latency of 313±56 ms. Perceptual performance averaged 53±4%, 63±4%, 65±2% correct at 100, 200, and 300 ms, respectively. We conclude that, for the signal-to-noise ratio used, at the time of initiation of the first saccade there is little difference between the amount of information about target location available to the perceptual and saccadic systems.

2002 ◽  
Vol 13 (01) ◽  
pp. 038-049 ◽  
Author(s):  
Gabrielle H. Saunders ◽  
Kathleen M. Cienkowski

Measurement of hearing aid outcome is particularly difficult because there are numerous dimensions to consider (e.g., performance, satisfaction, benefit). Often there are discrepancies between scores in these dimensions. It is difficult to reconcile these discrepancies because the materials and formats used to measure each dimension are so very different. We report data obtained with an outcome measure that examines both objective and subjective dimensions with the same test format and materials and gives results in the same unit of measurement (signal-to-noise ratio). Two variables are measured: a “performance” speech reception threshold and a “perceptual” speech reception threshold. The signal-to-noise ratio difference between these is computed to determine the perceptual-performance discrepancy (PPDIS). The results showed that, on average, 48 percent of the variance in subjective ratings of a hearing aid could be explained by a combination of the performance speech reception threshold and the PPDIS. These findings suggest that the measure is potentially a valuable clinical tool.


2012 ◽  
Vol 126 (10) ◽  
pp. 1010-1015 ◽  
Author(s):  
V Possamai ◽  
G Kirk ◽  
A Scott ◽  
D Skinner

AbstractObjectives:To assess the feasibility of designing and implementing a speech in noise test in children before and after grommet insertion, and to analyse the results of such a test in a small group of children.Methods:Twelve children aged six to nine years who were scheduled to undergo grommet insertion were identified. They underwent speech in noise testing before and after grommet insertion. This testing used Arthur Boothroyd word lists read at 60 dB in four listening conditions presented in a sound field: firstly in quiet conditions, then in signal to noise ratios of +10 (50 dB background noise), 0 (60 dB) and −10 (70 dB).Results:Mean phoneme scores were: in quiet conditions, 28.1 pre- and 30 post-operatively (p = 0.04); in 50 dB background noise (signal to noise ratio +10), 24.2 pre- and 29 post-operatively (p < 0.01); in 60 dB background noise (signal to noise ratio 0), 22.6 pre- and 27.5 post-operatively (p = 0.06); and in 70 dB background noise (signal to noise ratio −10), 13.9 pre- and 21 post-operatively (p = 0.05).Conclusion:This small study suggests that speech in noise testing is feasible in this scenario. Our small group of children demonstrated a significant improvement in speech in noise scores following grommet insertion. This is likely to translate into a significant advantage in the educational environment.


2017 ◽  
Vol 14 (1) ◽  
pp. 149-160
Author(s):  
Lazar Cokic ◽  
Aleksandra Marjanovic ◽  
Sanja Vujnovic ◽  
Zeljko Djurovic

In this paper a short theoretical overview of differential quantizer and its implementations is given. Afterward, the effect of the order of prediction in differential quantizer and the effect of the difference in order of predictor in the input and output of differential quantizer is analyzed. Then it was proceeded with the examination of the robustness of the differential quantizer in the case in which a noise signal is brought to the input of the differential quantizer, instead of the clean speech signal. The analysis was conducted with a uniform distribution, as well as the noise with the gaussian distribution, and the obtained results were adequately commented on. Also, experimentally a limit was set which refers to the intensity of the noise and still enable results which are better that a regular uniform quantizer. The whole analysis is done by using the fixed number of bits in quantization, i.e. 12-bit quantizer is used in all the implementations of differential quantizer. In the conclusion of this paper there is a discussion about the possibility of implementing a differential quantizer which will be able to recognize which noise attacks the system, and in addition to that, in what form it adapts its coefficients so that it at any moment acquires the optimal signal to noise ratio.


2016 ◽  
Vol 34 (3) ◽  
Author(s):  
Cristian D. Ariza A. ◽  
Milton J. Porsani

ABSTRACT. The ground-roll is a type of noise normally present in land seismic data. It strongly harms the signal-to-noise ratio, and interferes in several stages of the seismic data processing, strongly affecting the final quality of the obtained seismic images...Keywords: seismic noise, signal-to-noise ratio, adaptive filters, Burg algorithm, seismic signal decomposition.  RESUMO. O ground-roll é um tipo de ruído normalmente presente nos dados sísmicos terrestres. Ele prejudica muito a razão sinal-ruído e interfere em vários est´ágios do processamento de dados sísmicos, afetando fortemente a qualidade final das imagens sísmicas obtidas...Palavras-chave: ruídos sísmicos, relação sinal-ruído, filtragem adaptativo, algoritmo de Burg, decomposição do sinal sísmico.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Sign in / Sign up

Export Citation Format

Share Document