On-line automatic detection of wood pellets in pneumatically conveyed wood dust flow

2014 ◽  
Author(s):  
Duo Sun ◽  
Yong Yan ◽  
Robert M. Carter ◽  
Lingjun Gao ◽  
Xiangchen Qian ◽  
...  
Holzforschung ◽  
2008 ◽  
Vol 62 (4) ◽  
Author(s):  
Torbjörn A. Lestander

Abstract Samples of wood pellets were adjusted into six water content classes from 0% to 12%. The water content in single pellets varied between 0.1% and 14.2%. Three equations were constructed to estimate the differential heat of sorption (-ΔH) values from (1) fractal-geometry, (2) isosteric, and (3) calorimetric data. The ranges in calculated -ΔH of single pellets were (1) 133–1475, (2) 315–881, and (3) 195–1188 J g-1 water, respectively, across the studied moisture content range. Partial least squares regression was used to model near-infrared (NIR) spectra from single pellets and to predict -ΔH values and water content. The explained variation in test sets for the different models ranged from 97.1% to 99.9%. The shifts in peak absorbance for two water bands indicated that frequency in overtone vibration of O-H stretching and bending decreased, when water content was raised. Simulations of mixes between pellets of differential heat values showed that released heat was up to 0.03% of the gross calorific value of wood pellets. This heat may be a major contributor to initial temperature increases in pellet stacks during storage. The results indicate that on-line NIR based predictions of differential heat in wood pellets is possible to apply in the pellet industry.


2010 ◽  
Vol 34-35 ◽  
pp. 1810-1815
Author(s):  
An Du ◽  
Rui Na Ma ◽  
Yong Zhe Fan ◽  
Xiao Ming Cao ◽  
Shi Jie Li ◽  
...  

A spectral absorption of the ferrous ion in fluxing was investigated in this paper due to the significant effect of ferrous ion on the quality of hot-dip galvanizing production. Based on analysis of spectrophotometry, an automatic detection equipment of ferrous ions is developed according to its special characteristics. On-line measuring of ferrous ion in fluxing of the hot-dip galvanizing is realized by the micro-pump and the equipment. Results show that the lowest limit to be detected is 0.1 g/L, measuring errors are less than 0.05 g/L, the linear equations of the absorption and concentration of the ferrous ions shows a good correlation coefficient which is 0.99995 when the ferrous ions concentration is between 0.1g/L and 10g/L in fluxing.


2002 ◽  
Vol 12 ◽  
pp. 239-241
Author(s):  
Hermann Boehnhardt ◽  
Olivier Hainaut

AbstractWe propose a wide-shallow TNO search to be done with the Wide Field Imager (WFI) instrument at the 2.2m MPG/ESO telescope in La Silla/Chile. The WFI is a half-deg camera equipped with an 8kx8k CCD (0.24 arcsec/pixel). It was used in 1999 to run a pilot project for a TNO search. Using the images of typically 24mag limiting brightness and an automatic detection software (developed at ESO Chile) it was possible to discover 6 TNOs in a small search area of 1.5 sdeg. The project is now continued on a somewhat larger scale in order to discover more TNOs in a systematic way and to reach operational status for a full on-line detection of the objects as well as astrometric and photometric reduction at the telescope. The final goal is to perform a survey of a major part of the sky (typically 2000 sdeg in and out of the ecliptic) down to 24mag. Follow-up astrometry and photometry of the expected more than 3000 discovered objects will secure their orbital and physical characterisation for synoptic dynamical and taxonomic studies of the transneptunian population.


2014 ◽  
Vol 63 (5) ◽  
pp. 993-1001 ◽  
Author(s):  
Duo Sun ◽  
Yong Yan ◽  
Robert M. Carter ◽  
Lingjun Gao ◽  
Gang Lu ◽  
...  

2005 ◽  
Vol 32 (6Part1) ◽  
pp. 1521-1523 ◽  
Author(s):  
Laurence Smith ◽  
Mike Pleasance ◽  
Rosalyn Seeton ◽  
Neculai Archip ◽  
Robert Rohling

Sign in / Sign up

Export Citation Format

Share Document