PULSE-ECHO REFLECTIONOFTHE SH0 GUIDED WAVE MODE FROM A PART-THICKNESS ELLIPTICAL DEFECT IN A PLATE

2010 ◽  
Author(s):  
J. Ma ◽  
P. Cawley ◽  
M. Lowe ◽  
Donald O. Thompson ◽  
Dale E. Chimenti
2013 ◽  
Vol 113 (14) ◽  
pp. 144904 ◽  
Author(s):  
Pasi Karppinen ◽  
Ari Salmi ◽  
Petro Moilanen ◽  
Timo Karppinen ◽  
Zuomin Zhao ◽  
...  

Abstract. Micro-damages such as pores, closed delamination/debonding and fiber/matrix cracks in carbon fiber reinforced plastics (CFRP) are vital factors towards the performance of composite structures, which could collapse if defects are not detected in advance. Nonlinear ultrasonic technologies, especially ones involving guided waves, have drawn increasing attention for their better sensitivity to early damages than linear acoustic ones. The combination of nonlinear acoustics and guided waves technique can promisingly provide considerable accuracy and efficiency for damage assessment and materials characterization. Herein, numerical simulations in terms of finite element method are conducted to investigate the feasibility of micro-damage detection in multi-layered CFRP plates using the second harmonic generation (SHG) of asymmetric Lamb guided wave mode. Contact acoustic nonlinearity (CAN) is introduced into the constitutive model of micro-damages in composites, which leads to the distinct SHG compared with material nonlinearity. The results suggest that the generated second order harmonics due to CAN could be received and adopted for early damage evaluation without matching the phase of the primary waves.


2021 ◽  
Author(s):  
Christian Peyton ◽  
Rachel S. Edwards ◽  
Steve Dixon ◽  
Ben Dutton ◽  
Wilson Vesga

Abstract This paper investigates the interaction behaviour between the fundamental shear horizontal guided wave mode and small defects, in order to understand and develop an improved inspection system for titanium samples. In this work, an extensive range of defect sizes have been simulated using finite element software. The SH0 reflection from a defect has been shown previously to depend on its length as the total reflection consists of reflections from both the front and back face. However, for small defect widths, this work has found that the width also affects this interference, changing the length at which the reflection is largest. In addition, the paper looks at how the size of the defect affects the mode converted S0 reflection and SH0 diffraction. The relationship between the SH0 diffraction and defect size is shown to be more complex compared to the reflections. The mode converted S0 reflection occurs at an angle to the incident wave direction; therefore, the most suitable angle for the detection has been found. Simultaneous measurement of multiple waves would bring benefits to inspection.


Sensors ◽  
2019 ◽  
Vol 19 (24) ◽  
pp. 5443 ◽  
Author(s):  
Anurag Dhutti ◽  
Saiful Asmin Tumin ◽  
Wamadeva Balachandran ◽  
Jamil Kanfoud ◽  
Tat-Hean Gan

High-temperature (HT) ultrasonic transducers are of increasing interest for structural health monitoring (SHM) of structures operating in harsh environments. This article focuses on the development of an HT piezoelectric wafer active sensor (HT-PWAS) for SHM of HT pipelines using ultrasonic guided waves. The PWAS was fabricated using Y-cut gallium phosphate (GaPO4) to produce a torsional guided wave mode on pipes operating at temperatures up to 600 °C. A number of confidence-building tests on the PWAS were carried out. HT electromechanical impedance (EMI) spectroscopy was performed to characterise piezoelectric properties at elevated temperatures and over long periods of time (>1000 h). Laser Doppler vibrometry (LDV) was used to verify the modes of vibration. A finite element model of GaPO4 PWAS was developed to model the electromechanical behaviour of the PWAS and the effect of increasing temperatures, and it was validated using EMI and LDV experimental data. This study demonstrates the application of GaPO4 for guided-wave SHM of pipelines and presents a model that can be used to evaluate different transducer designs for HT applications.


Sensors ◽  
2020 ◽  
Vol 20 (15) ◽  
pp. 4335
Author(s):  
Jeong Nyeon Kim ◽  
Tianning Liu ◽  
Thomas N. Jackson ◽  
Kyusun Choi ◽  
Susan Trolier-McKinstry ◽  
...  

Piezoelectric micromachined ultrasound transducers (PMUT) incorporating lead zirconate titanate PbZr0.52Ti0.48O3 (PZT) thin films were investigated for miniaturized high-frequency ultrasound systems. A recently developed process to remove a PMUT from an underlying silicon (Si) substrate has enabled curved arrays to be readily formed. This research aimed to improve the design of flexible PMUT arrays using PZFlex, a finite element method software package. A 10 MHz PMUT 2D array working in 3-1 mode was designed. A circular unit-cell was structured from the top, with concentric layers of platinum (Pt)/PZT/Pt/titanium (Ti) on a polyimide (PI) substrate. Pulse-echo and spectral response analyses predicted a center frequency of 10 MHz and bandwidth of 87% under water load and air backing. A 2D array, consisting of the 256 (16 × 16) unit-cells, was created and characterized in terms of pulse-echo and spectral responses, surface displacement profiles, crosstalk, and beam profiles. The 2D array showed: decreased bandwidth due to protracted oscillation decay and guided wave effects; mechanical focal length at 2.9 mm; 3.7 mm depth of field for -6 dB; and -55.6 dB crosstalk. Finite element-based virtual prototyping identified figures of merit—center frequency, bandwidth, depth of field, and crosstalk—that could be optimized to design robust, flexible PMUT arrays.


2013 ◽  
Author(s):  
P. Puthillath ◽  
B. Ren ◽  
C. J. Lissenden ◽  
J. L. Rose

Sign in / Sign up

Export Citation Format

Share Document