Use of x-ray microbeams for cross-section depth profiling of MeV ion-implantation-induced defect clusters in Si

1999 ◽  
Vol 75 (18) ◽  
pp. 2791-2793 ◽  
Author(s):  
Mirang Yoon ◽  
B. C. Larson ◽  
J. Z. Tischler ◽  
T. E. Haynes ◽  
J.-S. Chung ◽  
...  
1998 ◽  
Vol 524 ◽  
Author(s):  
C. H. Chang ◽  
U. Beck ◽  
T. H. Metzger ◽  
J. R. Patel

ABSTRACTTo characterize the point defects and point defect clusters introduced by ion implantation and annealing, we have used grazing incidence x-rays to measure the diffuse scattering in the tails of Bragg peaks (Huang Scattering). An analysis of the diffuse scattered intensity will allow us to characterize the nature of point defects or defect clusters introduced by ion implantation. We have also observed unexpected satellite peaks in the diffuse scattered tails. Possible causes for the occurrence of the peaks will be discussed.


2012 ◽  
Vol 195 ◽  
pp. 274-276 ◽  
Author(s):  
Philipp Hönicke ◽  
Matthias Müller ◽  
Burkhard Beckhoff

The continuing shrinking of the component dimensions in ULSI technology requires junction depths in the 20-nm regime and below to avoid leakage currents. These ultra shallow dopant distributions can be formed by ultra-low energy (ULE) ion implantation. However, accurate measurement techniques for ultra-shallow dopant profiles are required in order to characterize ULE implantation and the necessary rapid thermal annealing (RTA) processes.


1997 ◽  
Vol 504 ◽  
Author(s):  
M. Soltani-Farshi ◽  
H. Baumann ◽  
D. Rück ◽  
G. Walter ◽  
K. Bethge

ABSTRACTThe influence of nitrogen ion implantation on the hydrogen accumulation in titanium was investigated as function of sample temperature and ion fluence. 150 keV nitrogen (15N) ions were implanted at different sample temperatures up to 700°C with fluences ranging from 1 × 1017 to 1 × 1018 ions/cm2. The amount of accumulated hydrogen and its depth distribution was measured quantitatively with the 15N depth profiling method. The implanted 15N depth profiles were measured by the reverse reaction 15N(p, αγ)12C at 429 keV. The binary phases of the implanted nitrogen with titanium are detected by grazing incidence x-ray diffraction. The results are compared with those obtained for samples implanted at RT and subsequently thermally treated.


2020 ◽  
Vol 35 (12) ◽  
pp. 2964-2973
Author(s):  
Mateusz Czyzycki ◽  
Mike Kokkoris ◽  
Andreas-Germanos Karydas

Grazing-incidence X-ray fluorescence is applied to obtain shallow depth distributions using the X-ray standing wave (XSW). A new XSW-free mathematical model is proposed that allows the quantitative derivation of much deeper depth distributions.


Author(s):  
Thomas S. Leeson ◽  
C. Roland Leeson

Numerous previous studies of outer segments of retinal receptors have demonstrated a complex internal structure of a series of transversely orientated membranous lamellae, discs, or saccules. In cones, these lamellae probably are invaginations of the covering plasma membrane. In rods, however, they appear to be isolated and separate discs although some authors report interconnections and some continuities with the surface near the base of the outer segment, i.e. toward the inner segment. In some species, variations have been reported, such as longitudinally orientated lamellae and lamellar whorls. In cross section, the discs or saccules show one or more incisures. The saccules probably contain photolabile pigment, with resulting potentials after dipole formation during bleaching of pigment. Continuity between the lamina of rod saccules and extracellular space may be necessary for the detection of dipoles, although such continuity usually is not found by electron microscopy. Particles on the membranes have been found by low angle X-ray diffraction, by low temperature electron microscopy and by freeze-etching techniques.


Author(s):  
Shawn Williams ◽  
Xiaodong Zhang ◽  
Susan Lamm ◽  
Jack Van’t Hof

The Scanning Transmission X-ray Microscope (STXM) is well suited for investigating metaphase chromosome structure. The absorption cross-section of soft x-rays having energies between the carbon and oxygen K edges (284 - 531 eV) is 6 - 9.5 times greater for organic specimens than for water, which permits one to examine unstained, wet biological specimens with resolution superior to that attainable using visible light. The attenuation length of the x-rays is suitable for imaging micron thick specimens without sectioning. This large difference in cross-section yields good specimen contrast, so that fewer soft x-rays than electrons are required to image wet biological specimens at a given resolution. But most imaging techniques delivering better resolution than visible light produce radiation damage. Soft x-rays are known to be very effective in damaging biological specimens. The STXM is constructed to minimize specimen dose, but it is important to measure the actual damage induced as a function of dose in order to determine the dose range within which radiation damage does not compromise image quality.


Author(s):  
Imre Pozsgai ◽  
Klara Erdöhalmi-Torok

The paintings by the great Hungarian master Mihaly Munkacsy (1844-1900) made in an 8-9 years period of his activity are deteriorating. The most conspicuous sign of the deterioration is an intensive darkening. We have made an attempt by electron beam microanalysis to clarify the causes of the darkening. The importance of a study like this is increased by the fact that a similar darkening can be observed on the paintings by Munkacsy’s contemporaries e.g Courbet and Makart. A thick brown mass the so called bitumen used by Munkacsy for grounding and also as a paint is believed by the art historians to cause the darkening.For this study, paint specimens were taken from the following paintings: “Studio”, “Farewell” and the “Portrait of the Master’s Wife”, all of them are the property of the Hungarian National Gallery. The paint samples were embedded in a polyester resin “Poly-Pol PS-230” and after grinding and polishing their cross section was used for x-ray mapping.


Author(s):  
Douglas L. Dorset

A variety of linear chain materials exist as polydisperse systems which are difficultly purified. The stability of continuous binary solid solutions assume that the Gibbs free energy of the solution is lower than that of either crystal component, a condition which includes such factors as relative molecular sizes and shapes and perhaps the symmetry of the pure component crystal structures.Although extensive studies of n-alkane miscibility have been carried out via powder X-ray diffraction of bulk samples we have begun to examine binary systems as single crystals, taking advantage of the well-known enhanced scattering cross section of matter for electrons and also the favorable projection of a paraffin crystal structure posited by epitaxial crystallization of such samples on organic substrates such as benzoic acid.


Author(s):  
G. Remond ◽  
R.H. Packwood ◽  
C. Gilles ◽  
S. Chryssoulis

Merits and limitations of layered and ion implanted specimens as possible reference materials to calibrate spatially resolved analytical techniques are discussed and illustrated for the case of gold analysis in minerals by means of x-ray spectrometry with the EPMA. To overcome the random heterogeneities of minerals, thin film deposition and ion implantation may offer an original approach to the manufacture of controlled concentration/ distribution reference materials for quantification of trace elements with the same matrix as the unknown.In order to evaluate the accuracy of data obtained by EPMA we have compared measured and calculated x-ray intensities for homogeneous and heterogeneous specimens. Au Lα and Au Mα x-ray intensities were recorded at various electron beam energies, and hence at various sampling depths, for gold coated and gold implanted specimens. X-ray intensity calculations are based on the use of analytical expressions for both the depth ionization Φ (ρz) and the depth concentration C (ρz) distributions respectively.


Author(s):  
Matthew T. Johnson ◽  
Ian M. Anderson ◽  
Jim Bentley ◽  
C. Barry Carter

Energy-dispersive X-ray spectrometry (EDS) performed at low (≤ 5 kV) accelerating voltages in the SEM has the potential for providing quantitative microanalytical information with a spatial resolution of ∼100 nm. In the present work, EDS analyses were performed on magnesium ferrite spinel [(MgxFe1−x)Fe2O4] dendrites embedded in a MgO matrix, as shown in Fig. 1. spatial resolution of X-ray microanalysis at conventional accelerating voltages is insufficient for the quantitative analysis of these dendrites, which have widths of the order of a few hundred nanometers, without deconvolution of contributions from the MgO matrix. However, Monte Carlo simulations indicate that the interaction volume for MgFe2O4 is ∼150 nm at 3 kV accelerating voltage and therefore sufficient to analyze the dendrites without matrix contributions.Single-crystal {001}-oriented MgO was reacted with hematite (Fe2O3) powder for 6 h at 1450°C in air and furnace cooled. The specimen was then cleaved to expose a clean cross-section suitable for microanalysis.


Sign in / Sign up

Export Citation Format

Share Document