Design of FeBi nanoparticles for imaging applications

2014 ◽  
Vol 175 ◽  
pp. 97-111 ◽  
Author(s):  
M. Branca ◽  
F. Pelletier ◽  
B. Cottin ◽  
D. Ciuculescu ◽  
C.-C. Lin ◽  
...  

A variety of imaging technologies are now routinely used in the medical field, their use being continuously enlarged through the development of contrast agents. Recently nanoparticles (NPs) proved efficient to improve imaging in vivo by increasing contrast and targeting capabilities. The current trend is now focused on the development of dual contrast agents combining two or more functionalities on the same NP. Motivated by this new challenge we developed FeBi NPs as new nanomaterials with potential application as a contrast agent for MRI and CT imaging. In addition to the well-known use of iron in the development MRI contrast agents, we chose Bi as a CT imaging agent rather than the more documented gold, because it possesses a larger X-ray attenuation coefficient and is much less expensive. Two sets of NPs, with sizes around 150 nm and 14 nm, were synthesized using organometallic approaches. In both cases, the NPs are spherical, and contain distinct domains of Fe and Bi, with the surface being enriched with Fe, and a hydrophobic coating. This coating differs from one sample to the other: the surfaces of the 150 nm large NPs are coated by amine ligands, while those of the 14 nm large NPs are coated by a mixture of an amine and its hydrochloride salt. Exchange of the surface ligands to afford water soluble NPs has been attempted. We show that only the larger NPs could be functionalized with water soluble ligands, which is in agreement with the lability of their initial surface coating. Colloidal aqueous solutions of FeBi NPs with glycoPEG ligands have been obtained.

2021 ◽  
Vol 9 (7) ◽  
pp. 1787-1791
Author(s):  
Run Wang ◽  
Lu An ◽  
Jing He ◽  
Mengmeng Li ◽  
Jingjing Jiao ◽  
...  

Water-soluble Fe(iii) coordination complexes were fabricated as T1-weighted magnetic resonance imaging contrast agents in vivo.


2021 ◽  
Vol 11 (3) ◽  
pp. 1165
Author(s):  
Wen-Tien Hsiao ◽  
Yi-Hong Chou ◽  
Jhong-Wei Tu ◽  
Ai-Yih Wang ◽  
Lu-Han Lai

The purpose of this study is to establish the minimal injection doses of magnetic resonance imaging (MRI) contrast agents that can achieve optimized images while improving the safety of injectable MRI drugs. Gadolinium-diethylenetriamine penta-acetic acid (Gd-DTPA) and ferucarbotran, commonly used in clinical practice, were selected and evaluated with in vitro and in vivo experiments. MRI was acquired using T1-weighted (T1W) and T2-weighted (T2W) sequences, and the results were quantitatively analyzed. For in vitro experiments, results showed that T1W and T2W images were optimal when Gd-DTPA-bisamide (2-oxoethyl) (Gd-DTPA-BMEA) and ferucarbotran were diluted to a volume percentage of 0.6% and 0.05%; all comparisons were significant differences in grayscale statistics using one-way analysis of variance (ANOVA). For in vivo experiments, the contrast agent with optimal concentration percentages determined from in vitro experiments were injected into mice with an injection volume of 100 μL, and the images of brain, heart, liver, and mesentery before and after injection were compared. The statistical results showed that the p values of both T1W and T2W were less than 0.001, which were statistically significant. Under safety considerations for MRI contrast agent injection, optimized MRI images could still be obtained after reducing the injection concentration, which can provide a reference for the safety concentrations of MRI contrast agent injection in the future.


2011 ◽  
Vol 40 (14) ◽  
pp. 3616 ◽  
Author(s):  
Hong Yang ◽  
Hong Zhou ◽  
Cuixia Zhang ◽  
Xuejian Li ◽  
He Hu ◽  
...  

Carbon ◽  
2006 ◽  
Vol 44 (3) ◽  
pp. 496-500 ◽  
Author(s):  
Chun-Ying Shu ◽  
Li-Hua Gan ◽  
Chun-Ru Wang ◽  
Xin-long Pei ◽  
Hong-bin Han

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Christian E. Anderson ◽  
Mette Johansen ◽  
Bernadette O. Erokwu ◽  
He Hu ◽  
Yuning Gu ◽  
...  

AbstractSynchronous assessment of multiple MRI contrast agents in a single scanning session would provide a new “multi-color” imaging capability similar to fluorescence imaging but with high spatiotemporal resolution and unlimited imaging depth. This multi-agent MRI technology would enable a whole new class of basic science and clinical MRI experiments that simultaneously explore multiple physiologic/molecular events in vivo. Unfortunately, conventional MRI acquisition techniques are only capable of detecting and quantifying one paramagnetic MRI contrast agent at a time. Herein, the Dual Contrast – Magnetic Resonance Fingerprinting (DC-MRF) methodology was extended for in vivo application and evaluated by simultaneously and dynamically mapping the intra-tumoral concentration of two MRI contrast agents (Gd-BOPTA and Dy-DOTA-azide) in a mouse glioma model. Co-registered gadolinium and dysprosium concentration maps were generated with sub-millimeter spatial resolution and acquired dynamically with just over 2-minute temporal resolution. Mean tumor Gd and Dy concentration measurements from both single agent and dual agent DC-MRF studies demonstrated significant correlations with ex vivo mass spectrometry elemental analyses. This initial in vivo study demonstrates the potential for DC-MRF to provide a useful dual-agent MRI platform.


2002 ◽  
Vol 9 (2) ◽  
pp. S495-S497 ◽  
Author(s):  
Masafumi Okumura ◽  
Masahito Mikawa ◽  
Takashi Yokawa ◽  
Yoko Kanazawa ◽  
Haruhito Kato ◽  
...  

2020 ◽  
Vol 11 (44) ◽  
pp. 11998-12008
Author(s):  
Alessandro Fracassi ◽  
Jianbo Cao ◽  
Naoko Yoshizawa-Sugata ◽  
Éva Tóth ◽  
Corey Archer ◽  
...  

LDL-mimetic lipid nanoparticles, decorated with MRI contrast agents and fluorescent dyes, were prepared by the covalent attachments of an apoB100-mimetic peptide, Gd(iii)-chelate, and rhodamine to enhance atherosclerosis in the in vivo imaging.


2020 ◽  
Vol 11 ◽  
pp. 1000-1009
Author(s):  
Miao Qin ◽  
Yueyou Peng ◽  
Mengjie Xu ◽  
Hui Yan ◽  
Yizhu Cheng ◽  
...  

The multimodal magnetic resonance imaging (MRI) technique has been extensively studied over the past few years since it offers complementary information that can increase diagnostic accuracy. Simple methods to synthesize contrast agents are necessary for the development of multimodal MRI. Herein, uniformly distributed Fe3O4/Gd2O3 nanocubes for T 1–T 2 dual-mode MRI contrast agents were successfully designed and synthesized. In order to increase hydrophilicity and biocompatibility, the nanocubes were coated with nontoxic 3,4-dihydroxyhydrocinnamic acid (DHCA). The results show that iron (Fe) and gadolinium (Gd) were homogeneously distributed throughout the Fe3O4/Gd2O3-DHCA (FGDA) nanocubes. Relaxation time analysis was performed on the images obtained from the 3.0 T scanner. The results demonstrated that r 1 and r 2 maximum values were 67.57 ± 6.2 and 24.2 ± 1.46 mM−1·s−1, respectively. In vivo T 1- and T 2-weighted images showed that FGDA nanocubes act as a dual-mode contrast agent enhancing MRI quality. Overall, these experimental results suggest that the FGDA nanocubes are interesting tools that can be used to increase MRI quality, enabling accurate clinical diagnostics.


Small ◽  
2014 ◽  
Vol 10 (6) ◽  
pp. 1116-1124 ◽  
Author(s):  
Imen Miladi ◽  
Christophe Alric ◽  
Sandrine Dufort ◽  
Pierre Mowat ◽  
Aurélie Dutour ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document