Towards an improved qualitative and quantitative determination of glutathione peroxidase, selenoprotein P and selenoalbumin in human serum by HPLC coupled to ICP-MS

2010 ◽  
Vol 2 (9) ◽  
pp. 1382 ◽  
Author(s):  
Petru Jitaru ◽  
Giulio Cozzi ◽  
Roberta Seraglia ◽  
Pietro Traldi ◽  
Paolo Cescon ◽  
...  
Chemosensors ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 77
Author(s):  
Davide Spanu ◽  
Gilberto Binda ◽  
Marcello Marelli ◽  
Laura Rampazzi ◽  
Sandro Recchia ◽  
...  

A laser ablation–inductively coupled plasma–mass spectrometry (LA–ICP–MS) based method is proposed for the quantitative determination of the spatial distribution of metal nanoparticles (NPs) supported on planar substrates. The surface is sampled using tailored ablation patterns and the data are used to define three-dimensional functions describing the spatial distribution of NPs. The volume integrals of such interpolated surfaces are calibrated to obtain the mass distribution of Ag NPs by correlation with the total mass of metal as determined by metal extraction and ICP–MS analysis. Once this mass calibration is carried out on a sacrificial sample, quantifications can be performed over multiple samples by a simple micro-destructive LA–ICP–MS analysis without requiring the extraction/dissolution of metal NPs. The proposed approach is here tested using a model sample consisting of a low-density polyethylene (LDPE) disk decorated with silver NPs, achieving high spatial resolution over cm2-sized samples and very high sensitivity. The developed method is accordingly a useful analytical tool for applications requiring both the total mass and the spatial distribution of metal NPs to be determined without damaging the sample surface (e.g., composite functional materials and NPs, decorated catalysts or electrodic materials).


2021 ◽  
Author(s):  
Yiwen Cao ◽  
Shenjie Zhu ◽  
Lin Zhang ◽  
Qun Cui ◽  
Haiyan Wang

Aiming at the difficulty in qualitative and quantitative analysis of trace compositions in food preservative propionic acid, the trace compositions and the key components influencing the total aldehyde content in...


1987 ◽  
Vol 20 (4) ◽  
pp. 290-291
Author(s):  
M. Moss ◽  
C.S.Y. Wong ◽  
T. McMahon ◽  
C. Cousins ◽  
C. Jacklyn

2011 ◽  
Vol 66 (1) ◽  
pp. 102-108 ◽  
Author(s):  
Shihu Wei ◽  
Peicheng Zhang ◽  
Xizhi Feng ◽  
Hiroyuki Kodama ◽  
Changyuan Yu ◽  
...  

Author(s):  
BS Dattilo ◽  
S Gallo ◽  
G Lionetti ◽  
SG Rossi

AbstractA new method is described for the qualitative and quantitative determination of both free and bound maleic hydrazide residues in tobacco leaves and cigarette filler by high performance liquid chromatography. Analyses were carried out by hydrolyzing samples of ground tobacco with 4 N hydrochloric acid for 40 minutes under reflux followed by sample chromatography, running isocratic elutions with a dilute solution of phosphoric acid. The quantitative determination of maleic hydrazide was performed by light absorption at 320 nm, by the calibration curve method. Recoveries of maleic hydrazide added to tobacco samples were greater than 90 %. The detection limit of the method, determined on ground tobacco leaves, was at least 5 ppm. The results obtained by this procedure and by the ISO standard method no. 4876 are in good accordance.


2010 ◽  
Vol 878 (29) ◽  
pp. 2943-2948 ◽  
Author(s):  
Shuli Man ◽  
Wenyuan Gao ◽  
Yanjun Zhang ◽  
Jieyin Wang ◽  
Wanshun Zhao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document