Trace lead measurement and on-line removal of matrix interference in seawater by isotope dilution coupled with flow injection and ICP-MS

2004 ◽  
Vol 508 (2) ◽  
pp. 239-245 ◽  
Author(s):  
Zhi-Yong Huang ◽  
Fa-Rong Chen ◽  
Zhi-Xia Zhuang ◽  
Xiao-Ru Wang ◽  
Frank S.C. Lee
1998 ◽  
Vol 70 (5) ◽  
pp. 1036-1040 ◽  
Author(s):  
August A. Specht ◽  
Diane Beauchemin

2016 ◽  
Vol 31 (1) ◽  
pp. 270-279 ◽  
Author(s):  
David N. Douglas ◽  
Jennifer O'Reilly ◽  
Ciaran O'Connor ◽  
Barry L. Sharp ◽  
Heidi Goenaga-Infante

A strategy, systematically developed, is reported for the quantitative analysis of the Fe spatial distribution in biological tissue using laser ablation with ICP-MS and on-line double isotope dilution analysis.


2015 ◽  
Vol 93 (11) ◽  
pp. 1226-1231 ◽  
Author(s):  
R. Douglas Evans ◽  
Andrei Izmer ◽  
Karima Benkhedda ◽  
Andrew Toms ◽  
Angelo Fernando ◽  
...  

A measurement system capable of continuous on-line matrix removal, pre-concentration and analysis of 226Ra using pre-packed columns coupled to a flow injection system and an ICP-MS was developed. Full instrumental control of both the ICP-MS and the flow injection system provided automatic integration of the transient signals. The flow injection system was programmed to control column conditioning, sample loading, column rinsing, analyte elution and column cleaning operations employing appropriate solutions. The application of this system to the 226Ra analysis of an industrial liquid effluent was demonstrated. Using this particular instrument together with pre-concentration and matrix removal procedures, a limit of detection of 5.4 fg L−1 (2 mBq L−1) and a method detection limit of 16.2 fg L−1 (6 mBq L−1) were achieved for the measurement of 226Ra using a 25 mL sample volume. Total time for sample handling and analysis is approximately 10 minutes. The concentration of 226Ra in a discharged effluent sample was 0.73 pg L−1 (27 mBq L−1), which is in good agreement with the value of 0.81 pg L−1 (30 mBq L−1) measured using conventional alpha counting techniques.


2019 ◽  
Vol 34 (2) ◽  
pp. 407-412 ◽  
Author(s):  
David Clases ◽  
Raquel Gonzalez de Vega ◽  
Paul A. Adlard ◽  
Philip A. Doble

We present a novel on-line isotope dilution analysis (IDA) approach for the quantification of isotopically enriched metal labels used in immunohistochemical assisted imaging mass spectrometry.


2011 ◽  
Vol 402 (1) ◽  
pp. 439-448 ◽  
Author(s):  
Björn Meermann ◽  
Marc Bockx ◽  
Aline Laenen ◽  
Cis Van Looveren ◽  
Filip Cuyckens ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document