scholarly journals Diagnostic accuracy of postmortem ultrasound vs 1.5T postmortem MRI for non‐invasive perinatal autopsies

Author(s):  
Susan Cheng Shelmerdine ◽  
Neil James Sebire ◽  
Owen John Arthurs
2020 ◽  
Vol 13 (4) ◽  
pp. 184-190
Author(s):  
Muhammad Irfan ◽  
Abdul Rasheed Qureshi ◽  
Zeeshan Ashraf ◽  
Muhammad Amjad Ramzan ◽  
Tehmina Naeem ◽  
...  

ABSTRACT Background: Conventionally Pleural effusions are suspected by history of pleuritis, evaluated by physical signs and multiple view radiography. Trans-thoracic pleural aspiration is done and aspirated pleural fluid is considered the gold-standard for pleural effusion. Chest sonography has the advantage of having high diagnostic efficacy over radiography for the detection of pleural effusion. Furthermore, ultrasonography is free from radiation hazards, inexpensive, readily available  and feasible for use in ICU, pregnant and pediatric patients. This study aims to explore the diagnostic accuracy of trans-thoracic ultrasonography for pleural fluid detection, which is free of such disadvantages. The objective is to determine the diagnostic efficacy of trans-thoracic ultrasound for detecting pleural effusion and also to assess its suitability for being a non-invasive gold-standard.   Subject and Methods: This retrospective study of 4597 cases was conducted at pulmonology  OPD-Gulab Devi Teaching Hospital, Lahore from November 2016 to July 2018. Adult patients with clinical features suggesting pleural effusions were included while those where no suspicion of pleural effusion, patients < 14 years and pregnant ladies were excluded. Patients were subjected to chest x-ray PA and Lateral views and chest ultrasonography was done by a senior qualified radiologist in OPD. Ultrasound-guided pleural aspiration was done in OPD & fluid was sent for analysis. At least 10ml aspirated fluid was considered as diagnostic for pleural effusion. Patient files containing history, physical examination, x-ray reports, ultrasound reports, pleural aspiration notes and informed consent were retrieved, reviewed and findings were recorded in the preformed proforma. Results were tabulated and conclusion was drawn by statistical analysis. Results: Out of 4597 cases, 4498 pleural effusion were manifested on CXR and only 2547(56.62%) pleural effusions were proved by ultrasound while 2050 (45.57%) cases were reported as no Pleural effusion. Chest sonography demonstrated sensitivity, specificity, PPV, NPV and diagnostic accuracy 100 % each. Conclusions: Trans-thoracic ultrasonography revealed an excellent efficacy that is why it can be considered as non-invasive gold standard for the detection of pleural effusion.


BJS Open ◽  
2021 ◽  
Vol 5 (1) ◽  
Author(s):  
M J Wilkinson ◽  
H Snow ◽  
K Downey ◽  
K Thomas ◽  
A Riddell ◽  
...  

Abstract Background Diagnosis of lymph node (LN) metastasis in melanoma with non-invasive methods is challenging. The aim of this study was to evaluate the diagnostic accuracy of six LN characteristics on CT in detecting melanoma-positive ilioinguinal LN metastases, and to determine whether inguinal LN characteristics can predict pelvic LN involvement. Methods This was a single-centre retrospective study of patients with melanoma LN metastases at a tertiary cancer centre between 2008 and 2016. Patients who had preoperative contrast-enhanced CT assessment and ilioinguinal LN dissection were included. CT scans containing significant artefacts obscuring the pelvis were excluded. CT scans were reanalysed for six LN characteristics (extracapsular spread (ECS), minimum axis (MA), absence of fatty hilum (FH), asymmetrical cortical nodule (CAN), abnormal contrast enhancement (ACE) and rounded morphology (RM)) and compared with postoperative histopathological findings. Results A total of 90 patients were included. Median age was 58 (range 23–85) years. Eighty-eight patients (98 per cent) had pathology-positive inguinal disease and, of these, 45 (51 per cent) had concurrent pelvic disease. The most common CT characteristics found in pathology-positive inguinal LNs were MA greater than 10 mm (97 per cent), ACE (80 per cent), ECS (38 per cent) and absence of RM (38 per cent). In multivariable analysis, inguinal LN characteristics on CT indicative of pelvic disease were RM (odds ratio (OR) 3.3, 95 per cent c.i. 1.2 to 8.7) and ECS (OR 4.2, 1.6 to 11.3). Cloquet’s node is known to be a poor predictor of pelvic spread. Pelvic LN disease was present in 50 per cent patients, but only 7 per cent had a pathology-positive Cloquet’s node. Conclusion Additional CT radiological characteristics, especially ECS and RM, may improve diagnostic accuracy and aid clinical decisions regarding the need for inguinal or ilioinguinal dissection.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
L Stazzoni ◽  
L Tessandori ◽  
P Spontoni ◽  
M Angelillis ◽  
C Giannini ◽  
...  

Abstract Background Instantaneous Wave-Free Ratio (iFR) allows for the assessment of the haemodynamic effects of epicardial coronary stenoses without the need for hyperaemia; iFR is currently recommended as a means to evaluate myocardial ischaemia. Purpose To assess the diagnostic accuracy of iFR with respect to the identification of coronary epicardial stenoses causing ischemia. Therefore, we combined anatomical (% stenosis at invasive coronary angiography, ICA) and functional (non-invasive imaging stress test, NIST) information to obtain a “gold standard” for the identification of stenoses causing ischaemia. Methods We enrolled 71 patients (52 male, 19 female; age mean 68.4±8.1 years) with chronic coronary syndrome or low-risk acute coronary syndrome without ST segment elevation who had at least a NIST and who had at least one vessel with a 50%-85% stenosis at ICA. iFR was measured in all coronary arteries with stenosis &gt;50% and categorised according to the 0.89 threshold for ischaemia. Results iFR was assessed in 122 vessels. In a per-vessel analysis, in 56.7% ischaemia was present both at iFR and NIST, in 21.3% ischaemia was absent in both, while in 23.0% ischaemia was found at NIST but not confirmed by iFR. The overall accuracy of iFR with respect to NIST was 90.1%. However, when considering as the “gold standard” for coronary disease causing ischaemia the contemporary presence of an epicardial stenosis &gt;70% at ICA and a positive NIST, the diagnostic accuracy of iFR greatly improved. The sensibility, specificity, PPV, NPV and accuracy were 96.5%, 75.0%, 73.3%, 96.7% and 84.4%, respectively. In case of discordance between NIST and iFR, revascularization was based on iFR. At a mean follow-up of 23±18 months, the composite endpoint of MACE (major adverse cardiac events, defined as the composite of all-cause death, nonfatal MI and unplanned coronary revascularization) occurred in 16.4%, while death/MI occurred in 11.9%. Stratification according to the per-patient concordance between iFR and NIST showed no significant differences in rates of MACE (p=0.50) and death/MI (p=0.20). Stratification based on iFR showed a higher death/MI rate in iFR-positive patients (11.9% vs. 0%, p=0.047) and a trend to higher MACE rate (11.9% vs. 4.47% p=0.14), Conclusions The diagnostic accuracy of iFR is low when compared with NIST as the reference for myocardial ischaemia, but it is very high when compared with the combined presence of epicardial stenosis and positive NIST. Therefore, iFR can accurately guide the decision to treat or defer revascularization of intermediate coronary stenoses, being most useful in patients with multivessel CAD and when non-invasive functional data are lacking or discordant with anatomy. Funding Acknowledgement Type of funding source: None


2018 ◽  
Vol 12 (supplement_1) ◽  
pp. S200-S201
Author(s):  
D Abdulganieva ◽  
D Mukhametova ◽  
A Odintsova

2017 ◽  
Vol 46 (6) ◽  
pp. 617-627 ◽  
Author(s):  
S. Petta ◽  
V. W.-S. Wong ◽  
C. Cammà ◽  
J.-B. Hiriart ◽  
G. L.-H. Wong ◽  
...  

Author(s):  
Pooja J. Mise ◽  
Sangamesh J. Mise ◽  
Aditya Mise ◽  
Margol Siddappa

Background: Transvaginal sonography (TVS) is a new diagnostic technique used for the evaluation of the female pelvis. The objective of the present study was to study the role of TVS and to assess the diagnostic accuracy in gynecological disorders.Methods: Total number of 100 patients attending OPDs with various complaints was selected by random technique of the study.  All the patients have informed consent and thorough clinical examination including general, systemic and pelvic examination was conducted after taking a detailed history then the patients underwent TVS followed by one of the procedures like fractional curettage, dilatation and curettage and abdominal hysterectomy (with or without conservation of ovaries) or conservative management with regular follow up.Results: The sensitivity of TVS in diagnosing dysfunctional uterine bleeding (DUB) and pelvic inflammatory diseases (PID) was 100% and specificity was 85.1% and 95% respectively. For fibroids and ovarian mass diagnosis, sensitivity was 68.9% and 80.9% respectively and specificity was 100%. Diagnostic accuracy of clinical diagnosis was 70.0% whereas TVS had 94.0% of diagnostic accuracy in diagnosing various gynecological disorders.Conclusions: The final outcome is that TVS examination is an important non-invasive investigation, can be used as important diagnostic method in various gynecological disorders as it has got a high diagnostic accuracy.


1987 ◽  
Vol 48 (11) ◽  
pp. 1779-1783
Author(s):  
Kazuhiko YOSHIDA ◽  
Fujio KASUMI ◽  
Atsuo FUKAMI ◽  
Kenji NISHIHARA ◽  
Ikuo NAGANO ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document