Three‐dimensional interventional photoacoustic imaging for biopsy needle guidance with a linear array transducer

2019 ◽  
Vol 12 (12) ◽  
Author(s):  
Hang Wang ◽  
Songde Liu ◽  
Tong Wang ◽  
Chenxi Zhang ◽  
Ting Feng ◽  
...  
Author(s):  
Suhyun Park ◽  
Andrei B. Karpiouk ◽  
Salavat R. Aglyamov ◽  
Stanislav Y. Emelianov

Sensors ◽  
2020 ◽  
Vol 20 (14) ◽  
pp. 4052
Author(s):  
João H. Uliana ◽  
Diego R. T. Sampaio ◽  
Guilherme S. P. Fernandes ◽  
María S. Brassesco ◽  
Marcello H. Nogueira-Barbosa ◽  
...  

Photoacoustic imaging (PAI) combines optical contrast with ultrasound spatial resolution and can be obtained up to a depth of a few centimeters. Hand-held PAI systems using linear array usually operate in reflection mode using a dark-field illumination scheme, where the optical fiber output is attached to both sides of the elevation plane (short-axis) of the transducer. More recently, bright-field strategies where the optical illumination is coaxial with acoustic detection have been proposed to overcome some limitations of the standard dark-field approach. In this paper, a novel multiangle long-axis lateral illumination is proposed. Monte Carlo simulations were conducted to evaluate light delivery for three different illumination schemes: bright-field, standard dark-field, and long-axis lateral illumination. Long-axis lateral illumination showed remarkable improvement in light delivery for targets with a width smaller than the transducer lateral dimension. A prototype was developed to experimentally demonstrate the feasibility of the proposed approach. In this device, the fiber bundle terminal ends are attached to both sides of the transducer’s long-axis and the illumination angle of each fiber bundle can be independently controlled. The final PA image is obtained by the coherent sum of subframes acquired using different angles. The prototype was experimentally evaluated by taking images from a phantom, a mouse abdomen, forearm, and index finger of a volunteer. The system provided light delivery enhancement taking advantage of the geometry of the target, achieving sufficient signal-to-noise ratio at clinically relevant depths.


2014 ◽  
Author(s):  
Haroon Zafar ◽  
Aedán Breathnach ◽  
Hrebesh M. Subhash ◽  
Martin J. Leahy

Author(s):  
Guangzhi Dai ◽  
Zhiyong He ◽  
Hongwei Sun

Background: This study is carried out targeting the problem of slow response time and performance degradation of imaging system caused by large data of medical ultrasonic imaging. In view of the advantages of CS, it is applied to medical ultrasonic imaging to solve the above problems. Objective: Under the condition of satisfying the speed of ultrasound imaging, the quality of imaging can be further improved to provide the basis for accurate medical diagnosis. Methods: According to CS theory and the characteristics of the array ultrasonic imaging system, block compressed sensing ultrasonic imaging algorithm is proposed based on wavelet sparse representation. Results: Three kinds of observation matrices have been designed on the basis of the proposed algorithm, which can be selected to reduce the number of the linear array channels and the complexity of the ultrasonic imaging system to some extent. Conclusion: The corresponding simulation program is designed, and the result shows that this algorithm can greatly reduce the total data amount required by imaging and the number of data channels required for linear array transducer to receive data. The imaging effect has been greatly improved compared with that of the spatial frequency domain sparse algorithm.


Sensors ◽  
2018 ◽  
Vol 18 (8) ◽  
pp. 2477 ◽  
Author(s):  
Jubo Hao ◽  
Jin Li ◽  
Yiming Pi

Due to the non-contact detection ability of radar and the harmlessness of terahertz waves to the human body, three-dimensional (3D) imaging using terahertz synthetic aperture radar (SAR) is an efficient method of security detection in public areas. To achieve high-resolution and all aspect imaging, circular trajectory movement of radar and linear sensor array along the height direction were used in this study. However, the short wavelength of terahertz waves makes it practically impossible for the hardware to satisfy the half-wavelength spacing condition to avoid grating lobes. To solve this problem, a sparse linear array model based on the equivalent phase center principle was established. With the designed imaging geometry and corresponding echo signal model, a 3D imaging algorithm was derived. Firstly, the phase-preserving algorithm was adopted to obtain the 2D image of the ground plane for each sensor. Secondly, the sparse recovery method was applied to accomplish the scattering coefficient reconstruction along the height direction. After reconstruction of all the range-azimuth cells was accomplished, the final 3D image was obtained. Numerical simulations and experiments using terahertz radar were performed. The imaging results verify the effectiveness of the 3D imaging algorithm for the proposed model and validate the feasibility of terahertz radar applied in security detection.


2013 ◽  
Vol 21 (22) ◽  
pp. 26671 ◽  
Author(s):  
Antonio M. Caravaca-Aguirre ◽  
Donald B. Conkey ◽  
Jacob D. Dove ◽  
Hengyi Ju ◽  
Todd W. Murray ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document