scholarly journals Comparative Three-Dimensional Morphology of Baleen: Cross-Sectional Profiles and Volume Measurements Using CT Images

2017 ◽  
Vol 300 (11) ◽  
pp. 1942-1952 ◽  
Author(s):  
Megan M. Jensen ◽  
Amalia H. Saladrigas ◽  
Jeremy A. Goldbogen
2018 ◽  
Vol 21 (3) ◽  
pp. 134-137
Author(s):  
Yong Cheol Jun ◽  
Young Lae Moon ◽  
Moustafa I Elsayed ◽  
Jae Hwan Lim ◽  
Dong Hyuk Cha

BACKGROUND: In a previous study undertaken to quantify capsular volume in rotator cuff interval or axillary pouch, significant differences were found between controls and patients with instability. However, the results obtained were derived from two-dimensional cross sectional areas. In our study, we sought correlation between three-dimensional (3D) capsular volumes, as measured by magnetic resonance arthrography (MRA), and multidirectional instability (MDI) of the shoulder.METHODS: The MRAs of 21 patients with MDI of the shoulder and 16 control cases with no instability were retrospectively reviewed. Capsular areas determined by MRA were translated into 3D volumes using 3D software Mimics ver. 16 (Materilise, Leuven, Belgium), and glenoid surface area was measured in axial and coronal MRA views. Then, the ratio between capsular volume and glenoid surface area was calculated, and evaluated with control group.RESULTS: The ratio between 3D capsular volume and glenoid surface area was significantly increased in the MDI group (3.59 ± 0.83 cm³/cm²) compared to the control group (2.53 ± 0.62 cm³/cm²) (p < 0.01).CONCLUSIONS: From these results, we could support that capsular volume enlargement play an important role in MDI of the shoulder using volume measurement.


2012 ◽  
Vol 51 (03) ◽  
pp. 73-78 ◽  
Author(s):  
A. Darr ◽  
J.-H. Schierz ◽  
E. Schleußner ◽  
S. Wiegand ◽  
T. Opfermann ◽  
...  

SummaryPurpose: It has recently become possible to generate and archive three-dimensional ultrasound (3D-US) volume data with the DICOM standard Enhanced Ultrasound Volume Storage (EUVS). The objective of this study was to examine the application of the EUVS standard based on the example of thyroid ultrasound. Patients, methods: 32 patients, who were referred for thyroid diagnosis, were given a 3D-US examination of the thyroid gland (GE Voluson E8, convex 3D probe RAB4–8-D). The 3D data sets were exported to EUVS. Necessary additions to DICOM entries and transformation into an established DICOM standard were carried out. The visual assessment and volume measurements were performed by two experts on nuclear medicine using standard software in our hospital. Results: In 24/32 (75%) of the patients, the whole organ was successfully recorded in a single 3D scan; in 8/32 (25%), only part of organ could be covered. In all cases, 3D-US data could be exported and archived. After supplementing the DICOM entry Patient Orientation and transformation into the DICOM PET format, 3D-US data could be displayed in the correct orientation and size at any viewing workstation and any web browser-based PACS viewer. Afterwards, 3D processing such as multiplanar reformation, volumetric measurements and image fusion with data of other cross sectional modalities could be performed. The intraclass correlation of the volume measurements was 0,94 and the interobserver variability was 5.7%. Conclusion: EUVS allows the generation, distribution and archiving of 3D-US data of the thyroid, facilitates a second reading by another physician and creates conditions for advanced 3D processing using routine software


2020 ◽  
Author(s):  
Naotoshi Fujita ◽  
Katsuhiko Kato ◽  
Shinji Abe ◽  
Shinji Naganawa

Abstract Background This study examined the variation in the thyroid volume determined by the ellipsoid approximation method due to differences in the measured length or area of the cross-sectional plane of CT images. Methods Forty-five patients with Graves' diseasewere included in this retrospective study. We designated the three-dimensional thyroid volumes extracted manually (VCT) as the reference data and calculated five approximate volumes for comparison: (1) the mean volume of 8100 different thyroid volumes depending on the diameter of the cross-sectional plane at the midpoint of the major axis, (Vellipsoid,mean); (2) the volume using the maximum diameter and its orthogonal diameter, (Vellipsoid,maxlength); (3) the maximum (Vellipsoid,maxvolume) and (4) minimum (Vellipsoid,minvolume) of the 8100 thyroid volumes; and (5) the volume determined with an equivalent circle diameter, (Vellipsoid,Heywood). Results Thyroid volumes obtained via the ellipsoid approximation method varied depending on the diameter of the cross-sectional plane and included a mean error of approximately 20%, while the concordance correlation coefficient (CCC) differed for each approximate volume. Among these volumes, Vellipsoid,meanand Vellipsoid,Heywoodwere in good agreement with VCT, according to single regression analyses and the resultant CCC values, with mean errors of 7.0% and 2.5%, respectively. Conclusion WhileVellipsoid,Heywoodapproximated thyroid volumes with vastly reduced errors, we recommend utilizing three-dimensional thyroid volumetry if measurement accuracy is required.


Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.


2021 ◽  
Vol 11 (8) ◽  
pp. 3404
Author(s):  
Majid Hejazian ◽  
Eugeniu Balaur ◽  
Brian Abbey

Microfluidic devices which integrate both rapid mixing and liquid jetting for sample delivery are an emerging solution for studying molecular dynamics via X-ray diffraction. Here we use finite element modelling to investigate the efficiency and time-resolution achievable using microfluidic mixers within the parameter range required for producing stable liquid jets. Three-dimensional simulations, validated by experimental data, are used to determine the velocity and concentration distribution within these devices. The results show that by adopting a serpentine geometry, it is possible to induce chaotic mixing, which effectively reduces the time required to achieve a homogeneous mixture for sample delivery. Further, we investigate the effect of flow rate and the mixer microchannel size on the mixing efficiency and minimum time required for complete mixing of the two solutions whilst maintaining a stable jet. In general, we find that the smaller the cross-sectional area of the mixer microchannel, the shorter the time needed to achieve homogeneous mixing for a given flow rate. The results of these simulations will form the basis for optimised designs enabling the study of molecular dynamics occurring on millisecond timescales using integrated mix-and-inject microfluidic devices.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Zhe Li ◽  
Guanzhi Liu ◽  
Run Tian ◽  
Ning Kong ◽  
Yue Li ◽  
...  

Abstract Background Our objective was to obtain normal patellofemoral measurements to analyse sex and individual differences. In addition, the absolute values and indices of tibial tuberosity-trochlear groove (TT-TG) distances are still controversial in clinical application. A better method to enable precise prediction is still needed. Methods Seventy-eight knees of 78 participants without knee pathologies were included in this cross-sectional study. A CT scan was conducted for all participants and three-dimensional knee models were constructed using Mimics and SolidWorks software. We measured and analysed 19 parameters including the TT-TG distance and dimensions and shapes of the patella, femur, tibia, and trochlea. LASSO regression was used to predict the normal TT-TG distances. Results The dimensional parameters, TT-TG distance, and femoral aspect ratio of the men were significantly larger than those of women (all p values < 0.05). However, after controlling for the bias from age, height, and weight, there were no significant differences in TT-TG distances and anterior-posterior dimensions between the sexes (all p values > 0.05). The Pearson correlation coefficients between the anterior femoral offset and other indexes were consistently below 0.3, indicating no relationship or a weak relationship. Similar results were observed for the sulcus angle and the Wiberg index. Using LASSO regression, we obtained four parameters to predict the TT-TG distance (R2 = 0.5612, p < 0.01) to achieve the optimal accuracy and convenience. Conclusions Normative data of patellofemoral morphology were provided for the Chinese population. The anterior-posterior dimensions of the women were thicker than those of men for the same medial-lateral dimensions. More attention should be paid to not only sex differences but also individual differences, especially the anterior condyle and trochlea. In addition, this study provided a new method to predict TT-TG distances accurately.


2021 ◽  
Vol 45 (3) ◽  
Author(s):  
C. M. Durnea ◽  
S. Siddiqi ◽  
D. Nazarian ◽  
G. Munneke ◽  
P. M. Sedgwick ◽  
...  

AbstractThe feasibility of rendering three dimensional (3D) pelvic models of vaginal, urethral and paraurethral lesions from 2D MRI has been demonstrated previously. To quantitatively compare 3D models using two different image processing applications: 3D Slicer and OsiriX. Secondary analysis and processing of five MRI scan based image sets from female patients aged 29–43 years old with vaginal or paraurethral lesions. Cross sectional image sets were used to create 3D models of the pelvic structures with 3D Slicer and OsiriX image processing applications. The linear dimensions of the models created using the two different methods were compared using Bland-Altman plots. The comparisons demonstrated good agreement between measurements from the two applications. The two data sets obtained from different image processing methods demonstrated good agreement. Both 3D Slicer and OsiriX can be used interchangeably and produce almost similar results. The clinical role of this investigation modality remains to be further evaluated.


Author(s):  
Shu Yan ◽  
Yan Jiang ◽  
Yan Wang ◽  
Kaixuan Chen ◽  
Xudong Yan ◽  
...  

Abstract Purpose To report our experience using endoscopic intranasal incision reduction (EIIR) for nasal fractures and to assess effectiveness of the method. Methods 30 patients who underwent EIIR were retrospectively analysed. All the patients were examined by three-dimensional computed tomography (3D CT), acoustic rhinometry and rhinomanometry, preoperatively and postoperatively at 1 month. The visual analogue scale (VAS) was used to assess the preoperative aesthetics and nasal airflow satisfaction and at 1, 3 and 6 months postoperatively. VAS aesthetic satisfaction was also scored by two junior doctors. Results 3D CT showed that the fracture fragments fitted well in 30 patients postoperatively at 1 month. VAS aesthetics and nasal airflow scores were significantly improved postoperatively at 1, 3 and 6 months compared with preoperative scores (P < 0.01). The VAS aesthetic scores from the two surgeons were also significantly improved (P < 0.01). The minimal cross-sectional area increased from 0.39 ± 0.13 to 0.64 ± 0.13 (P < 0.001), the nasal volume increased from 4.65 ± 0.86 to 6.37 ± 0.94 (P < 0.001) and the total inspiratory airway resistance of the bilateral nasal cavity median decreased from 0.467 Pa/mL/s to 0.193 Pa/mL/s (P < 0.001). There were no technique-related intraoperative complications. Conclusion EIIR was a practical choice, and the aesthetics and nasal airflow were significantly improved in patients with overlapped and displaced bone fragments, patients with fractures of the frontal process of the maxilla (FFPM), patients who underwent failed CR and patients beyond the optimal temporal window.


Sign in / Sign up

Export Citation Format

Share Document