scholarly journals Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs

Diagnostics ◽  
2021 ◽  
Vol 11 (5) ◽  
pp. 757
Author(s):  
Maged Sultan Alhammadi ◽  
Abeer Abdulkareem Al-mashraqi ◽  
Rayid Hussain Alnami ◽  
Nawaf Mohammad Ashqar ◽  
Omar Hassan Alamir ◽  
...  

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18–30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland–Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.

2008 ◽  
Vol 78 (5) ◽  
pp. 880-888 ◽  
Author(s):  
Brian Schlueter ◽  
Ki Beom Kim ◽  
Donald Oliver ◽  
Gus Sortiropoulos

Abstract Objective: To determine the ideal window level and width needed for cone beam computed three-dimensional (3D) reconstruction of the condyle. Materials and Methods: Linear dimensions were measured with a digital caliper to assess the anatomic truth for 50 dry human mandibular condyles. Condyles were scanned with the i-CAT cone beam computed tomography (CBCT) and 3D-models were reconstructed. Three linear three-dimensional measurements were made on each of the 50 condyles at 8 different Hounsfield unit (HU) windows. These measurements were compared with the anatomic truth. Volumetric measurements were also completed on all 50 condyles, at 23 different window levels, to define the volumetric distribution of bone mineral density (BMD) within the condyle. Results: Significant differences were found in two of the three linear measurement groups at and below the recommended viewing window for osseous structures. The most accurate measurements were made within the soft tissue range for HU window levels. Volumetric distribution measurements revealed that the condyles were mostly comprised of low-density bone, and that condyles exhibiting significant changes in linear measurements were shown to have higher percentages of low-density bone than those condyles with little change from the anatomic truth. Conclusions: CBCT assessment of the mandibular condyle, using the 3D reconstruction, is most accurate when accomplished at density levels below that recommended for osseous examination. However, utilizing lower window levels which extend into the soft tissue range, may compromise one's capacity to view the bony topography.


2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Xueman Zhou ◽  
Xin Xiong ◽  
Zhebin Yan ◽  
Chuqiao Xiao ◽  
Yingcheng Zheng ◽  
...  

Objective. To assess the differences in hyoid bone position in patients with and without temporomandibular joint osteoarthrosis (TMJOA). Methods. The present cross-sectional study was conducted in 427 participants whose osseous status was evaluated using cone-beam computed tomography and classified into normal, indeterminate osteoarthrosis (OA), and OA. The hyoid bone position and craniofacial characteristics were evaluated using cephalograms. Patients were divided into the normal group (N = 89), indeterminate OA group (N = 182), and OA group (N = 156). Descriptive statistics, one-way analysis of variance, and age- and sex-based stratified analyses were performed. P < 0.05 was considered statistically significant. Results. The differences in Hy to MP, Hy-RGn, Hy to C3-RGn, C3-RGn, and Go-Hy-Me among the three groups were statistically significant. The differences in the Frankfort-mandibular plane angle, saddle angle, articular angle, gonial angle, ramus height, and posterior facial height were statistically significant. After adjusting age and sex, the Hy-RGn and C3-RGn in the normal group were significantly greater than the OA group. No statistical differences were observed in the hyoid measurements in the stratified analyses in males or subjects less than 18 years old. The differences in Hy to MP, Hy to C3-RGn, and Go-Hy-Me in female patients among the three groups were statistically significant. The differences in Hy to SN, Hy to FH, Hy to PP, Hy to MP, Hy-RGn, Hy-C3, Hy to C3-RGn, Go-Hy-Me, Hy-S, and C3-Hy-S in adults were statistically significant. Conclusion. The differences in the hyoid bone position, mainly relative to the mandible, were statistically significant in patients with or without TMJOA. The difference pattern varied among different age and sex groups. Clinical evaluation of the hyoid position must consider the age and sex of patients. Longitudinal studies are required to clarify the causal relationship between TMJOA and hyoid bone position.


2019 ◽  
Vol 89 (5) ◽  
pp. 758-767 ◽  
Author(s):  
Joorok Park ◽  
Sheldon Baumrind ◽  
Sean Curry ◽  
Sean K. Carlson ◽  
Robert L. Boyd ◽  
...  

ABSTRACT Objectives: To quantify reliability of three-dimensional skeletal landmarks and a comprehensive set of dental landmarks in cone-beam computed tomography (CBCT) and to determine the shapes of envelope of error. Materials and Methods: Three judges located 31 skeletal landmarks and 60 dental landmarks on the pre- and posttreatment CBCT images of 22 patients. Landmark error was determined by calculating the distance of deviation of landmark locations around their average. Standard deviation and mean radial spherical error were calculated. Scatterplots were constructed to characterize envelope of error. Results: The midline landmarks of the cranial base were highly reliable. Bilateral skeletal landmarks tended to have larger error than midline landmarks. Among the nonconventional landmarks, fronto-zygomatic suture, condyle, and mental foramen showed relatively high reliability. However, foramen spinosum and temporal fossa showed larger errors. Gonion was the least reliable landmark. Most dental landmarks were located more reliably than skeletal landmarks. The highest reliability was found at incisal edges. Mesiobuccal cusp of first molars also showed high reliability. Conclusions: There were differences in the size and shape of the distributions of errors of different landmarks. Most landmarks showed elongated envelopes. Bilateral structures tended to show greater errors than midline structures. Most dental landmarks were more reliable than skeletal landmarks.


2020 ◽  
Vol 9 (6) ◽  
pp. 457-465
Author(s):  
Patricio Meléndez-Rojas ◽  
◽  
Leniz Arancibia-Mesas ◽  
Carolina Poblete-Carrasco ◽  
◽  
...  

Soft tissue calcifications can indicate the presence of more serious, potentially life-threatening pathologies. Therefore, their study can lead to an early diagnosis of those conditions that have not yet become clinically apparent. Main objective: To determine the prevalence of calcifications in soft tissues of the head and neck in cone beam computed tomography images obtained from the Oral and Maxillofacial Radiology Service at Universidad Andrés Bello (UNAB), Viña del Mar, Chile. Material and Methods: Retrospective, cross-sectional, quantitative study. A total of 288 images of cone beam computed tomography (CBCT) were used. Images were obtained at random from the database of the Oral and Maxillofacial Radiology Service at UNAB, Viña Del Mar, between 2014 and 2019. Results: A prevalence of 59.72% of soft tissue calcifications was obtained. The most prevalent were: tonsilloliths and calcified stylohyoid ligament, accounting for 30.65% and 45.56%, respectively. Conclusion: A high prevalence of soft tissue calcifications was found in a population that has not been studied previously; therefore, it is important that the dentist perform a detailed analysis of the cone beam computed tomography.


2020 ◽  
pp. 1-9
Author(s):  
Nasser Alqhtani ◽  
Fawaz Alqahtani ◽  
Abdulrahman Almalki ◽  
Ahmed Alanazi ◽  
Hamad Alkhuriaf ◽  
...  

BACKGROUND: Assessment of buccal alveolar bone thickness (ABT) and crown-to-root dimensions are essential in implant density; therefore, three-dimensional evaluation of these parameters provides a superior visualization than conventional radiographs. OBJECTIVE: The present cross-sectional cohort study aims to investigate the relationship between buccal ABT and crown-to-root dimensions around the mandibular first and second molars using cone-beam-computed tomography (CBCT). METHODS: Initially, CBCT-based scans from 271 individuals were assessed. Based on the inclusion and exclusion criteria, 171 CBCT-based scans were excluded. In total, 100 CBCT-scans were included in the present investigation and processed for data extraction. On the mandibular first and second molars, the mesial and distal root lengths and mesiodistal diameter of the crowns were measured. The pulpal floor served as a reference point for assessment of root length. The buccal ABT was measured at the coronal, middle and apical one-third of the root. Statistical analysis was performed and the level of significance was set at P< 0.01. One-hundred CBCT-scans from 294 mandibular teeth (137 first molars and 157 second molars) were included. One hundred and eighty-nine and 105 teeth were from males and females, respectively. RESULTS: The normality plot showed a normal data distribution. The mesiodistal crown width showed a weak yet significant correlation with mesial root length (r= 0.137), bone thickness at mesial apical third (r= 0.180), distal apical (r= 0.157) and distal coronal third (r= 0.161). Bone thickness at mesial, middle and apical third correlated significantly with one other (r= 0.786). CONCLUSION: There is a direct correlation between the buccal ABT and tooth dimensions around the mandibular first and second molars.


2013 ◽  
Vol 84 (2) ◽  
pp. 337-342 ◽  
Author(s):  
Koshu Katayama ◽  
Tetsutaro Yamaguchi ◽  
Mami Sugiura ◽  
Shugo Haga ◽  
Koutaro Maki

ABSTRACT Objective: To investigate the association between maxillofacial morphology and mandibular bone volume in patients with skeletal malocclusion. Materials and Methods: Subjects were 118 adult Japanese (58 males and 60 females). Skeletal malocclusion was classified, based on cephalometric analysis, into skeletal Classes I (−1° ≤ ANB &lt; 4°), II (ANB ≥ 4°), and III (ANB &lt; −1°). Using cone-beam computed tomography and three-dimensional image analysis software, the dental crowns and mandible were separated, with only the mandible extracted. This was then reconstructed as a three-dimensional model, from which the mandibular volume was measured. Results: No significant difference in mandibular volume was noted among skeletal Classes I, II, and III, nor was there any significant correlation between mandibular volume and the ANB, SNB, or mandibular plane angles. There was occasional and limited correlation between mandible volume and gonial angle and certain cephalometric distance parameters. Conclusion: We conclude that proper understanding of the three-dimensional maxillofacial morphology requires not only cephalometric radiographic tracings but also high-resolution analysis of the mandibular area, width, and volume.


Urolithiasis ◽  
2021 ◽  
Author(s):  
R. A. Kingma ◽  
M. J. H. Voskamp ◽  
B. H. J. Doornweerd ◽  
I. J. de Jong ◽  
S. Roemeling

AbstractCone beam computed tomography (CBCT) provides multiplanar cross-sectional imaging and three-dimensional reconstructions and can be used intraoperatively in a hybrid operating room. In this study, we investigated the feasibility of using a CBCT-scanner for detecting residual stones during percutaneous nephrolithotomy (PCNL). Intraoperative CBCT-scans were made during PCNL procedures from November 2018 until March 2019 in a university hospital. At the point where the urologist would have otherwise ended the procedure, a CBCT-scan was made to image any residual fragments that could not be detected by either nephroscopy or conventional C-arm fluoroscopy. Residual fragments that were visualized on the CBCT-scan were attempted to be extracted additionally. To evaluate the effect of this additional extraction, each CBCT-scan was compared with a regular follow-up CT-scan that was made 4 weeks postoperatively. A total of 19 procedures were analyzed in this study. The mean duration of performing the CBCT-scan, including preparation and interpretation, was 8 min. Additional stone extraction, if applicable, had a mean duration of 11 min. The mean effective dose per CBCT-scan was 7.25 mSv. Additional extraction of residual fragments as imaged on the CBCT-scan occurred in nine procedures (47%). Of the follow-up CT-scans, 63% showed a stone-free status as compared to 47% of the intraoperative CBCT-scans. We conclude that the use of CBCT for the detection of residual stones in PCNL is meaningful, safe, and feasible.


Author(s):  
Ibraheim Ahmed Diab ◽  
Shaimaa Abdel-hamid Hassanein ◽  
Hala Hafez Mohamed

Abstract Background Hepatocellular carcinoma (HCC) is the most common primary hepatic malignancy of adults. One of the established treatment procedures performed worldwide for HCC is transcatheter arterial chemoembolization (TACE). By using conventional angiography in TACE, we can detect and identify the vascular anatomy of the liver through obtaining 2D images. Recently C-arm cone beam computed tomography (CBCT) is introduced for obtaining cross-sectional and three-dimensional (3D) images for better visualization of small tumors and their feeding arteries. Results The number of detected focal lesions by angiography was 51 compared to 87 focal lesion detected by CBCT; of those, 45 and 77 were active lesions by both procedures respectively. For lesions, less than 1 cm CBCT detected 23 lesions while angiography detected only one lesion. Angiography detected 87 feeding arterial branch while cone beam CT-HA detected 130 branches to the same number of target lesion. Feeder tractability and confidence were better by CBCT. Conclusion CBCT is superior to angiography in tumor detectability, detection of lesions less than 1 cm, feeder detection, and feeder traction; however, conventional angiography and DSA are irreplaceable. Thus, combination of CBCT with angiography during TACE produces better results and less complication.


Author(s):  
Marcin Stasiak ◽  
Anna Wojtaszek-Słomińska ◽  
Bogna Racka-Pilszak

Abstract Purpose The aims of this retrospective cross-sectional study were to measure and compare labial and palatal alveolar bone heights of maxillary central incisors in unilateral cleft lip and palate patients, following STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Patients and methods The study group consisted of 21 patients with a mean age of 16 years. High-resolution cone-beam computed tomography was performed at least one year after secondary alveolar bone grafting. The experimental side was the cleft side and the contralateral side without congenital cleft was the control. Measurements were performed on incisors’ midsagittal cross-sections. The Wilcoxon signed-rank test was used for intergroup comparisons. Results The labial and palatal distances between alveolar bone crests and cementoenamel junctions were significantly greater on the cleft side than on the noncleft side. Mean differences were 0.75 and 1.41 mm, respectively. The prevalence of dehiscences at the cleft side maxillary central incisors was 52% on the labial surface and 43% on the palatal surface. In the controls, it was 19% and 14%, respectively. Conclusion The cleft-adjacent maxillary central incisors had more apically displaced alveolar bone crests on the labial and palatal sides of the roots than the controls. Higher prevalence of dehiscences was found on the cleft side. Bone margin differences predispose to gingival height differences of the central incisors. These differences could increase the demands of patients to obtain more esthetic treatment results with orthodontic extrusion and periodontal intervention on the cleft side.


Sign in / Sign up

Export Citation Format

Share Document