conditioning room
Recently Published Documents


TOTAL DOCUMENTS

25
(FIVE YEARS 4)

H-INDEX

2
(FIVE YEARS 0)

2017 ◽  
Vol 3 (6) ◽  
pp. 404
Author(s):  
Dwi M. Syabani ◽  
Hana Eliyani ◽  
Suharsono Suharsono ◽  
Fedik A. Rantam ◽  
Anwar Ma’ruf

Estimation of Postmortem is one of the challenges in forensic science. The aim of this study was to construct a  MARS  model of  Postmortem interval  estimation time (PMT)  from  algor mortis temperature in Rat. Sixteen healthy male rats (Rattus norvegicus), onemonth old and weigh 100 gram were randomly divided into two groups (eight/each group) and were acclimated respectively among the ambient room (temperature over 28ºC) and at the conditioning room (temperature over 20ºC). The animals then were sacrificed in two days (four rats/day  for each divided room) then algor mortis by rectal temperature  were recorded after death at 0 and 2,4,6,8, 10,12, 14,16, 18,20 till 22 h respectively. The MARS model is nonlinear regression but performed as a multilinier curve that can have splines fitting and be defined as function model Y = 35.321 + 1.253 * BF1 + 0.436 * BF2 - 1.319 * BF3; and on 20ºC condition room as Y = 29.980 + 1.354 * BF1 + 0.799 * BF2 - 1.347 * BF3. Therefore,  performance model was comprised by multilinier  curve, then function model of  algor mortis on ambient  room be defined into three PMT intervals i.e: 1)Y=37,94 -0.11*(0-2h)  (p>0.00); 2) Y = 40.88 - 1.87* (2-6h) ( p<0.00) and 3) Y=30.82-0.09*(6-22h)  (p<0.00)  while on 20ºC condition room, was : 1)Y = 34.78-0.09* (0-2h) (p<0.00) ; 2) Y = 37.97-2.38* (2-6h) (p<0.00) and  3)Y = 25.36-0.04* 6-22 h (p>0.00). The acceleration of the declining algor mortis at conditioning room showed steeper than on ambient room at 2-6h PMT interval   (ß : 2,38 vs  1,87). Postmortem Time Interval Estimation from  Algormortis Temperature of Rats could be expressed by MARS Model. The pattern model of estimation comprised by multilinear curve with splines was fitted at both of the experimental rooms.Keywords : Postmortem time interval, algor mortis, MARS model estimation


2015 ◽  
Vol 121 ◽  
pp. 114-121 ◽  
Author(s):  
Zhiqiang Kang ◽  
Yixian Zhang ◽  
Hongbo Fan ◽  
Guohui Feng

2014 ◽  
Vol 694 ◽  
pp. 536-541
Author(s):  
Wan Ming Qiang ◽  
Su Juan Fu ◽  
Yang Jin

Taking an example of a passive public construction project of building the research and development center in hebei province and based on dynamic analysis of energy consumption principle, this models passive public buildings and simulates energy consumption, it concludes cold index that construction demands in air conditioning season is 5.93W/m2 and 23.75W/m2 in heating season. Where in the condition of sunshade and opening lighting in part of air conditioning room when calculating the difference between the air-conditioning season building energy consumption, it shows that shading effect is more obvious in 13:00~15:00pm,and Saving rate is 0.72%.Experimental study on the above analysis provides reference to Passive public buildings energy-saving operation.


Sign in / Sign up

Export Citation Format

Share Document