atomic emission detector
Recently Published Documents


TOTAL DOCUMENTS

46
(FIVE YEARS 2)

H-INDEX

13
(FIVE YEARS 0)

2021 ◽  
Vol 14 (3) ◽  
pp. 1817-1831
Author(s):  
Einar Karu ◽  
Mengze Li ◽  
Lisa Ernle ◽  
Carl A. M. Brenninkmeijer ◽  
Jos Lelieveld ◽  
...  

Abstract. A gas detection system has been developed, characterized, and deployed for pressurized gas-phase sample analyses and near-real-time online measurements. It consists of a cryogenic pre-concentrator (CryoTrap), a gas chromatograph (GC), and a new high-resolution atomic emission detector (AED III HR). Here the CryoTrap–GC–AED instrumental setup is presented, and the performance for iodine (1635 ± 135 counts I atom−1 pptv−1), sulfur (409 ± 57 counts S atom−1 pptv−1), carbon (636 ± 69 counts C atom−1 pptv−1), bromine (9.1 ± 1.8 counts Br atom−1 pptv−1), and nitrogen (28 ± 2 counts N atom−1 pptv−1) emission lines is reported and discussed. The limits of detection (LODs) are in the low parts per trillion by volume range (0.5–9.7 pptv), and the signal is linear to at least 4 orders of magnitude, which makes it a suitable method for diverse volatile organic compound (VOC) measurements in the atmosphere, even in remote unpolluted regions. The new system was utilized in a field study in a boreal forest at Hyytiälä, Finland, in late summer 2016, which made monoterpene measurements possible among other VOCs. Furthermore, pressurized global whole-air samples, collected on board the Lufthansa Airbus A340-600 IAGOS–CARIBIC aircraft in the upper troposphere and lower stratosphere region, were measured with the new setup, providing data for many VOCs, including the long-lived organosulfur compound carbonyl sulfide.


2020 ◽  
Author(s):  
Einar Karu ◽  
Mengze Li ◽  
Lisa Ernle ◽  
Carl A. M. Brenninkmeijer ◽  
Jos Lelieveld ◽  
...  

Abstract. A gas detection system has been developed, characterized and deployed for pressurized gas phase sample analyses and near real-time online measurements. It consists of a cryogenic pre-concentrator (CryoTrap), a gas chromatograph (GC), and a new high-resolution atomic emission detector (AED III). Here the CryoTrap–GC–AED instrumental setup is presented and the performance for iodine (1635 ± 135 counts I-atom-1 pptv-1), sulfur (409 ± 57 counts S-atom-1 pptv-1), carbon (636 ± 69 counts C-atom-1 pptv-1), bromine (9.1 ± 1.8 counts Br-atom-1 pptv-1) and nitrogen (28 ± 2 counts N-atom-1 pptv-1) emission lines is reported and discussed. The limits of detection (LODs) are in the low pptv range (0.5–9.7 pptv) and the signal is linear to at least 4 orders of magnitude, which makes it a suitable method for diverse volatile organic compound (VOC) measurements in the atmosphere, even in remote, unpolluted regions. The new system was utilized in a field study in a boreal forest at Hyytiälä, Finland in late summer 2016 which made monoterpene measurements possible among the other VOCs. Furthermore, pressurized global whole-air sample measurement collected onboard the Lufthansa Airbus A340-600 IAGOS-CARIBIC aircraft in the upper troposphere and lower stratosphere region was carried out with the new setup, providing the observational data of many VOCs, including the long-lived organosulfur compound carbonyl sulfide.


2013 ◽  
Vol 62 (3) ◽  
pp. 199-206 ◽  
Author(s):  
Tatsuro NAKAGAMA ◽  
Kensuke SHINOHARA ◽  
Shinji UCHIYAMA ◽  
Jun TSUNOKAWA ◽  
Hulie ZENG ◽  
...  

2012 ◽  
Vol 61 (11) ◽  
pp. 969-977 ◽  
Author(s):  
Mieko KANAMORI-KATAOKA ◽  
Masumi TACHIKAWA ◽  
Ryoji SEKIOKA ◽  
Hiroshi SEKIGUCHI ◽  
Hisashi MARUKO ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document