station structure
Recently Published Documents


TOTAL DOCUMENTS

90
(FIVE YEARS 13)

H-INDEX

5
(FIVE YEARS 0)

2022 ◽  
Vol 119 ◽  
pp. 104255
Author(s):  
Zhidong Gao ◽  
Mi Zhao ◽  
Jingqi Huang ◽  
Weiwei Wang ◽  
Xiuli Du

2021 ◽  
Vol 11 (24) ◽  
pp. 11927
Author(s):  
Huafei He ◽  
Zhaoping Li

The seismic response of a fabricated subway station is a complex structural connection problem that depends on the mechanical properties of the joints. In order to obtain the optimal joint distribution of a fabricated station structure under earthquake action, three finite element models of a single ring structure of fabricated subway stations assembled with seven, five, and four prefabricated components were proposed. Seismic wave characteristics, peak acceleration, and coupled horizontal and vertical seismic components were considered to study the seismic response of the fabricated subway station structure with different forms of the joint distribution. The dynamic time history method was used to analyze the seismic response in three aspects: structure plastic strain, interlayer relative deformation, and internal force. The damage indexes and residual strength indexes of the joints were offered based on the concrete damage index to evaluate the joints’ damage degree. The results showed that the joints of the vault or bottom plate had little influence on the seismic response of the fabricated station structure. The sidewall joints had the obvious seismic response and the most severe damage under horizontal ground motion or coupled ground motion, which were the weak joints of the fabricated station structure. The existence of vertical ground motion aggravated the damage degree of sidewall joints, making the damage occurrence time of sidewall joints earlier and the damage end time extended. On the premise of meeting the mechanical load and site requirements, an assembly scheme with fewer prefabricated components can be selected.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Ying Zeng ◽  
Shiguang Xu ◽  
Shiqian Yin

China Earthquake Parameter Zoning (2016) has increased the seismic fortification intensity in Chengdu from VII to VIII. It is necessary to conduct in-depth discussion on the impact of the seismic performance of the built underground station structure. In this paper, a stratum-structure finite element model is established with a Chengdu subway station as an example. The model boundary adopts viscoelastic boundary, and the ground motion is input in the form of equivalent nodal force. The equivalent linearization method is used to consider the nonlinearity of soil materials. The time-history analysis of seismic fortification intensity of VII and VIII degrees is carried out, respectively. By comparing the calculation results of the two seismic fortification intensity ground motion conditions, it is concluded that the connection between the side wall and the floor is the weakest position of the station structure under the action of the earthquake; the seismic fortification intensity is increased from VII to VIII to the internal force of the structure. It has a relatively large impact, especially the most obvious impact on the bending moment. The results of the verification of the seismic time-history analysis show that the increase of fortification intensity will have a more obvious impact on the structural deformation, and the structural design of the station can meet the safety performance requirements of VII and VIII degrees of seismic fortification. The research has certain reference significance for the seismic safety evaluation of the built underground station structure in Chengdu area.


2021 ◽  
Vol 2021 ◽  
pp. 1-18
Author(s):  
Sheng Li ◽  
Haiyang Zhuang ◽  
Wei Wang ◽  
Liguo Jin ◽  
Zhengfang Dong

In view of the seismic weak component of the single-frame-type subway station structure, the three-dimensional (3D) time-domain nonlinear finite element static-dynamic coupling analysis model of interaction between soil and subway station structure is established by, respectively, using rectangular reinforced concrete (RRC) columns, circular reinforced concrete (CRC) columns, and prefabricated concrete-filled steel tube (CFST) columns with a quick-connection device proposed in this article. This analysis model is further used to investigate the influence of different types of middle columns on the seismic response characteristics of the underground structure, such as the interstory displacement angle, seismic damage, and dynamic response. The results show that, compared with the rectangular columns, the circular columns with the equal moment of inertia suffer less damage in the earthquake and have better seismic performance. The prefabricated CFST columns can effectively ensure that the middle columns of the station structure are not severely damaged and can be replaced quickly after the earthquake, which improves the overall seismic performance of the subway station structure and the rapid recovery ability of the structural function after the earthquake.


Author(s):  
D. O. BANNIKOV ◽  
V. P. KUPRII ◽  
D. YU. VOTCHENKO

Purpose. Perform numerical analysis of the station structure. Take into account in the process of mathematical modeling the process of construction of station tunnels of a three-vaulted station. Obtain the regularities of the stress-strain state of the linings, which is influenced by the processes of soil excavation and lining construction. Methodology. To achieve this goal, a series of numerical calculations of models of the deep contour interval metro pylon station was performed. Three finite-element models have been developed, which reflect the stages of construction of a three-vaulted pylon station. Numerical analysis was performed on the basis of the finite element method, implemented in the calculation complex Lira for Windows. Modeling of the stress-strain state of the station tunnel linings and the soil massif was performed using rectangular, universal quadrangular and triangular finite elements, which take into account the special properties of the soil massif. Station tunnel linings are modeled by means of rod finite elements. Findings. Isofields of the stress-strain state in finite-element models reflecting the stages of construction are obtained. The vertical displacements and horizontal stresses that are characteristic of a three-vaulted pylon station are analyzed. The analysis of horizontal stresses proved that at the stage of opening of the middle tunnel the scheme of pylon operation is rather disadvantageous. The analysis of bending moments and normal forces was also carried out and the asymmetry of their distribution was noted. Originality. Based on the obtained patterns of distribution of stress-strain state and force factors, it is proved that numerical analysis of the station structure during construction is necessary to take measures to prevent or reduce deformation of frames that are in unfavorable conditions. Practical value. In the course of research, the regularities of changes in stresses, displacements, bending moments and normal forces in the models of the pylon station, which reflect the sequence of its construction, were obtained.


2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Xiuren Yang ◽  
Fang Lin ◽  
Meiqun Huang

The grouted mortise-tenon joint, invented as the connection between the large prefabricated components, is the key to the prefabricated underground structures, and the double-tenon joint is most widely used in the prefabricated metro station structure. This paper conducts characteristic analysis of bending stiffness with a 1 : 1 prototype test in key working direction of different joint types for grouted double mortise-tenon joint. The results show that the double-tenon joint is characteristic of variable stiffness under different loads. Change laws of double-tenon joint bending stiffness without and with auxiliary pretightening device in tension side and compression side are also discussed. The correlations for calculating double-tenon joint bending stiffness with various axial loads and bending moments are derived at last, which offers the theory foreshadowing of similar joints.


2021 ◽  
Vol 59 (3) ◽  
pp. 183-198
Author(s):  
N. D. Beklemishev ◽  
A. A. Boguslavskii ◽  
M. Yu. Belyaev ◽  
O. N. Volkov ◽  
V. V. Sazonov ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document