plastic front
Recently Published Documents


TOTAL DOCUMENTS

8
(FIVE YEARS 2)

H-INDEX

2
(FIVE YEARS 0)

2021 ◽  

Contents Structural components/Strukturbauteile Development of an energy-absorbing structural element made of polyamide integrated in the plastic front-end carrier of the new Mercedes S-Class ..... 1 Entwicklung eines energieabsorbierenden Strukturelements aus Polyamid integriert im Kunststoff-Frontendträger der neuen Mercedes S-Klasse ..... 5 BAGS: Highly-integrated front-end module carrier ..... 9 BAGS: Hochintegrierter Front End Modulträger ..... 19 Surfaces/Oberflächen Lightweight plastic construction with visible surface as examplified by the Volkswagen ID 3 tailgate ..... 29 Kunststoffleichtbau mit Sichtoberfläche am Beispiel der Heckklappe Volkswagen ID3 ..... 39 Breakthrough in producing soft and sustainable interior surfaces by injection moulding of TPE ..... 49 Simulation The all-new MAN high-roof cab – epoxy sandwich RTM – simulated using FEM and crashed under real conditions ..... 61 Epoxid-Sandwich-RTM – FEM gerechnet und real gecrasht ..... 75 Development and validation of a simulation methodology for the prediction of surface defects for plastic components with metallic effect pig...


2015 ◽  
Vol 1 (2) ◽  
pp. 58-64
Author(s):  
Shoichi Takekawa ◽  
Yoshihiko Ueda ◽  
Yoshihiko Ueda ◽  
Yoshihiro Hiramatsu ◽  
Hirotsugu Munechika ◽  
...  

Background: Autoradiography of tissue with radioactive substance such as Thorotrast by Fuji Computed Radiography (FCR) has been available. We obtained autoradiographs from Thorotrast-deposited tissue by FCR. However, the nature of  radiation from tissue with Thorotrast was not certain, because alpha particles are shielded by the plastic front of the FCR cassette. Therefore, we undertook investigation to clearly explain the nature of radiation from Thorotrast in case of autoradiography.Materials and Methods: Tissue blocks of liver and spleen with Thorotrast deposition were imaged by autoradiography using FCR, and radioactivity of tissue blocks was measured by a GM survey meter. Measurement was carried out by both with and without an aluminum plate between the tissue and the surface of GM survey meter to shield beta-rays.Results: Autoradiographs of the liver and spleen with Thorotrast were successful. It took only one day to obtain autoradiograph of the spleen, and 14 days for the liver. The radioactivity count decreased dramatically when an aluminum plate was inserted between the specimen and GM survey meter, but some radiation remained. The tissue blocks were contained in a plastic bag and the front of the Cassette of Imaging Plate is covered by a thin plastic board, so alpha-rays from Thorium dioxide in Thorotrast had been shielded from the beginning.Conclusion: We concluded that the radiation from the tissue blocks with Thorotrast in a plastic bag was mostly from beta-rays and less than 5% of radiation was from gamma-rays from the daughter nuclei of Thorium dioxide.


2014 ◽  
Vol 496-500 ◽  
pp. 2703-2706
Author(s):  
Ming He Sun

The multifunction treadmill from the rack, motor, adjustable power, running belts and instrument control panel composition, in order to ensure that the entire system stability and damping effectiveness of the system, the base frame all welded structures. Stent design is divided into two parts by plugging in the form of installation and removal, use of ABS plastic front and rear covers, analyzes and running with running board design, and wriggled plate design.


2013 ◽  
Vol 6 (1) ◽  
pp. 44-52 ◽  
Author(s):  
H.S. Park ◽  
X.P. Dang ◽  
A. Roderburg ◽  
B. Nau
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document