pulse flux
Recently Published Documents


TOTAL DOCUMENTS

6
(FIVE YEARS 2)

H-INDEX

2
(FIVE YEARS 0)

2021 ◽  
Vol 2103 (1) ◽  
pp. 012084
Author(s):  
Yu F Gunko ◽  
N A Gunko

Abstract The purpose of this work is to create a method for determining the aerodynamic characteristics of fine particles in a highly rarefied plasma. The created method is based on the theorem on the change in momentum imparted to the body. The “body+surrounding plasma” system was considered to be closed; therefore, the change in the momentum of the body is equal in the impulse of the incident flow and is opposite to it in direction. The change in the pulse flux is calculated using the statistical method. To compare the results and approbation of the calculation method, the deceleration forces of a spherical body in a flow of neutral gas were determined. Next, we calculated the drag coefficient from the side of the charged plasma component. The calculation results are presented in the graphs.


2021 ◽  
Vol 12 (2) ◽  
pp. 133-138
Author(s):  
A. M. Vodovozov

The paper considers the operation of radioisotope measuring devices under dynamic conditions, when the Poisson pulse flux at the output of the radiation detector becomes unsteady and the nonlinearity of the calibration curve of the device, the stochasticity of the radiation signal and the inertia of the meter significantly complicate the task of estimating the measured physical parameter. of the device and analysis of the possibility of its application for linearization of the characteristics of the device, increasing the speed of the devices and solving the measuring problem in real time.The process of nonlinear transformation of the radiation signal in the system is analyzed on the basis of the assumption about the exponential distribution of the intervals between the pulses of the information flow at the output of the radiation detector. A generalized algorithm for the synthesis of a given transformation function of a time-pulse computing device of a radioisotope device has been developed according to its mathematical description. To describe the transformation function given by a set of points, it is proposed to use its approximation by a power series.The proposed calculation formulas are verified by modeling in the Scilab program on a specific example of linearization of the curve of a radioisotope altimeter with a given tabular calibration characteristic. The results obtained confirm the expediency of using time-pulse computing devices for linearizing the conversion curve of radioisotope devices in real time.Carrying out calculations according to the proposed algorithms by means of modern microelectronics opens up new possibilities for expanding the field of application of radioisotope devices in dynamic problems of industrial flaw detection, measuring the parameters of object movement, thickness of rolled products and coatings, in devices for continuous monitoring of liquid media.


2020 ◽  
Vol 0 (2) ◽  
Author(s):  
Олег Григорович Левченко ◽  
Анна Олегівна Лук’яненко ◽  
Юрій Олексійович Полукаров

2013 ◽  
Vol 555 ◽  
pp. A28 ◽  
Author(s):  
O. Maron ◽  
M. Serylak ◽  
J. Kijak ◽  
K. Krzeszowski ◽  
D. Mitra ◽  
...  

2001 ◽  
Vol 280 (1) ◽  
pp. E31-E39 ◽  
Author(s):  
Cinzia L. Paolini ◽  
Giacomo Meschia ◽  
Paul V. Fennessey ◽  
Adrian W. Pike ◽  
Cecilia Teng ◽  
...  

Under normal physiological conditions, essential amino acids (EA) are transported from mother to fetus at different rates. The mechanisms underlying these differences include the expression of several amino acid transport systems in the placenta and the regulation of EA concentrations in maternal and fetal plasma. To study the relation of EA transplacental flux to maternal plasma concentration, isotopes of EA were injected into the circulation of pregnant ewes. Measurements of concentration and molar enrichment in maternal and fetal plasma and of umbilical plasma flow were used to calculate the ratio of transplacental pulse flux to maternal concentration (clearance) for each EA. Five EA (Met, Phe, Leu, Ile, and Val) had relatively high and similar clearances and were followed, in order of decreasing clearance, by Trp, Thr, His, and Lys. The five high-clearance EA showed strong correlation ( r 2 = 0.98) between the pulse flux and maternal concentration. The study suggests that five of the nine EA have similar affinity for a rate-limiting placental transport system that mediates rapid flux from mother to fetus, and that differences in transport rates within this group of EA are determined primarily by differences in maternal plasma concentration.


Sign in / Sign up

Export Citation Format

Share Document