electromagnetic immunity
Recently Published Documents


TOTAL DOCUMENTS

112
(FIVE YEARS 6)

H-INDEX

5
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Xin Xu ◽  
Zongren Dai ◽  
Yifan Wang ◽  
Mingfang Li ◽  
Yidong Tan

<div> <p></p><p></p><p>In this paper, a novel optical rotary sensor based on laser self-mixing interferometry is developed for the full-circle rotation measurement. The proposed sensor is convenient to use for it does not need any contact with the target or a cooperative mirror. A prototype is fabricated and tested. The measured results demonstrate a good performance compared with other optical rotary sensors, in terms of the 0.1 μrad resolution, the 2.33×10<sup>-4</sup> linearity and 2 μrad stability over one hour. Additionally, the repeatability error is below 14.66 mrad under 9-group full-circle tests, which exhibits the potential to be instrumentalized reliably. Error analysis and limitation discussion have been also carried out. Although the accuracy needs further improvement compared with the best rotary sensor, this method has its unique advantages of high resolution, non-cooperative target sensing and electromagnetic immunity. Hence, the proposed optical rotary sensor provides a promising alternative in precise rotation measurement, tremor tracing and nano-motion monitoring.</p><p></p><p></p></div><p></p><p>In this paper, a novel optical rotary sensor based on laser self-mixing interferometry is developed for the full-circle rotation measurement. The proposed sensor is convenient to use for it does not need any contact with the target or a cooperative mirror. A prototype is fabricated and tested. The measured results demonstrate a good performance compared with other optical rotary sensors, in terms of the 0.1 μrad resolution, the 2.33×10<sup>-4</sup> linearity and 2 μrad stability over one hour. Additionally, the repeatability error is below 14.66 mrad under 9-group full-circle tests, which exhibits the potential to be instrumentalized reliably. Error analysis and limitation discussion have been also carried out. Although the accuracy needs further improvement compared with the best rotary sensor, this method has its unique advantages of high resolution, non-cooperative target sensing and electromagnetic immunity. Hence, the proposed optical rotary sensor provides a promising alternative in precise rotation measurement, tremor tracing and nano-motion monitoring.</p><p></p>


2021 ◽  
Author(s):  
Xin Xu ◽  
Zongren Dai ◽  
Yifan Wang ◽  
Mingfang Li ◽  
Yidong Tan

<div> <p>An optical rotary sensor based on laser self-mixing interferometry is proposed, which enables noncontact and full-circle rotation measurement of non-cooperative targets with high resolution and sensitivity. The prototype demonstrates that the resolution is 0.1μrad and the linearity is 2.33×10<sup>-4</sup>. Stability of the prototype is 2μrad over 3600s and the repeatability error is below 0.84°under 9-gruop full-circle tests. The theoretical resolution reaches up to 16nrad. Random rotation has been successfully traced with a bionic hand to simulate the tremor process. Error analysis and limitation discussion have been also carried out in the paper. Although the accuracy needs further improvement compared with the best rotary sensor, this method has its unique advantages of non-cooperative target sensing, high sensitivity and electromagnetic immunity. Hence, the optical rotary sensor provides a promising alternative in precise rotation measurement, tremor tracing and nano-motion monitoring.</p> </div> <b><br></b>


2021 ◽  
Author(s):  
Xin Xu ◽  
Zongren Dai ◽  
Yifang Wang ◽  
Mingfang Li ◽  
Yidong Tan

<div> <p>An optical rotary sensor based on laser self-mixing interferometry is proposed, which enables noncontact and full-circle rotation measurement of non-cooperative targets with high resolution and sensitivity. The prototype demonstrates that the resolution is 0.1μrad and the linearity is 2.33×10<sup>-4</sup>. Stability of the prototype is 2μrad over 3600s and the repeatability error is below 0.84°under 9-gruop full-circle tests. The theoretical resolution reaches up to 16nrad. Random rotation has been successfully traced with a bionic hand to simulate the tremor process. Error analysis and limitation discussion have been also carried out in the paper. Although the accuracy needs further improvement compared with the best rotary sensor, this method has its unique advantages of non-cooperative target sensing, high sensitivity and electromagnetic immunity. Hence, the optical rotary sensor provides a promising alternative in precise rotation measurement, tremor tracing and nano-motion monitoring.</p> </div> <b><br></b>


2021 ◽  
Author(s):  
Xin Xu ◽  
Zongren Dai ◽  
Yifang Wang ◽  
Mingfang Li ◽  
Yidong Tan

<div> <p>An optical rotary sensor based on laser self-mixing interferometry is proposed, which enables noncontact and full-circle rotation measurement of non-cooperative targets with high resolution and sensitivity. The prototype demonstrates that the resolution is 0.1μrad and the linearity is 2.33×10<sup>-4</sup>. Stability of the prototype is 2μrad over 3600s and the repeatability error is below 0.84°under 9-gruop full-circle tests. The theoretical resolution reaches up to 16nrad. Random rotation has been successfully traced with a bionic hand to simulate the tremor process. Error analysis and limitation discussion have been also carried out in the paper. Although the accuracy needs further improvement compared with the best rotary sensor, this method has its unique advantages of non-cooperative target sensing, high sensitivity and electromagnetic immunity. Hence, the optical rotary sensor provides a promising alternative in precise rotation measurement, tremor tracing and nano-motion monitoring.</p> </div> <b><br></b>


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3090
Author(s):  
Libor Dražan ◽  
René Križan ◽  
Miroslav Popela

This article describes the effect of high-power electromagnetic environments (HPEMs) on the operation of all basic elements of electrical power networks. Frequency bands are defined for the HPEM environments. Attention is focused particularly on directed energy weapons (DEWs) and intentional electromagnetic interference (IEMI). A classification of DEW and IEMI generators in terms of E-field level and target distance from the DEW or IEMI generator antenna aperture is also described. The main focus of this article is on the design and testing of a low-tech DEW generator used to determine the electromagnetic immunity of standard electronic circuits. In addition, verification of electromagnetic immunity for a simple electronic circuit without adequate protection against the E-field is also explained. The outcome of this article is the determination of the E-field limits for fault-free operation, for malfunctioning states of the tested circuits and for irreversible destruction of the circuits. The measured E-field was compared to basic microwave radiation theory and to simulation results in COMSOL Multiphysics software (COMSOL, Inc. 100 District Avenue Burlington, MA 01803 USA).


Sign in / Sign up

Export Citation Format

Share Document