hfc refrigerant
Recently Published Documents


TOTAL DOCUMENTS

13
(FIVE YEARS 0)

H-INDEX

4
(FIVE YEARS 0)

The use of HC refrigerant mixtures has been a topic of current research in view of the concerns related to global warming and Ozone depletion problems caused by CFCs and HFCs.. The HC mixture as an alternate refrigerant has been reported to be a promising one in addressing the global warming and Ozone depletion problems. In the present work an experimental set-up is built up to test Vapour Compression Refrigeration (VCR) system with different refrigerants. The aim of this work is to investigate the performance analysis of Vapor Compression Refrigeration system with alternate refrigerants such as Hydrocarbon (HC) refrigerants mixture and compare with Hydro Fluoro Carbon (HFC) refrigerant (R134a) under the similar operating conditions. The alternate refrigerant mixture is selected in the combination of Propane (R290) and Iso-butane (R600a). The refrigeration system variables considered for the investigation of performance are evaporating temperature, condensing temperature and power consumption. The HC refrigerant mixture is observed to give superior performance compared to HFC refrigerant in terms of global warming.


2017 ◽  
Vol 24 (1) ◽  
pp. 31
Author(s):  
Salome Gonzales Chávez ◽  
Néstor Rosas Martínez

Se demuestra de forma experimental la mejora energética y económica de una refrigeradora tipo doméstica, a partir de solamente sustituir su refrigerante original R-12 (CFC de característica contaminante y degradante de la Capa de Ozono), por otro refrigerante del tipo ecológico (HFC) como el R-134a. Comúnmente se practica el reemplazo de una refrigeradora que usa CFC, por otra unidad nueva que utiliza refrigerante ecológico de origen. Sin embargo, en países en vías de desarrollo el sector residencial mayormente cuenta con refrigeradoras que operan con R-12 y con vida de uso superior a los 10 años, no obstante la existencia de acuerdos internacionales que prohíben su utilización. El experimento consistió en: 1) preparación del equipo de refrigeración (dotación de reguladores de carga en el condensador y evaporador, dosificadores de refrigerante y aceite de lubricación-fluidización e instrumentación), 2) protocolo de mediciones, desarrollo de pruebas de operación con R-12 y con refrigerante ecológico sustituto R-134ª para las diversas combinaciones de carga realizadas durante un amplio periodo de experimentación. La evaluación energética se basa en las comparaciones de los ciclos termodinámicos, balances energéticos, potencias y rendimientos, operando el sistema de refrigeración tanto con R-12 como con R-134a. Como resultados se obtienen que el sistema de refrigeración operando con refrigerante ecológico R-134a frente al refrigerante R-12 de origen, se logra condiciones termodinámicas estables de operación y menor consumo de potencia del compresor, para cualquier condición de carga y en amplios periodos de operación. Por tanto, una de las soluciones más convenientes desde el punto de vista socioeconómico, es la sustitución solamente del refrigerante CFC en la misma refrigeradora usada (antigua), haciendo los ajustes y apropiada dosificación del refrigerante ecológico y del aceite de lubricación-fluidización. Palabras clave.- Refrigeración doméstica, Refrigerante CFC, Refrigerante ecológico HFC, Capa de ozono, Eficiencia energética, Confiabilidad, Economía. ABSTRACTWe demonstrate experimentally the energy and economic improvement of a domestic refrigerator, after only replace the original refrigerant R-12 (CFC) on the other ecological refrigerant R-134b (HFC). Commonly a refrigerator using CFC is replaced with new green refrigerator. However, in developing countries the residential sector has mostly refrigerators operating with R-12 and life exceeding 10 years use, despite the existence of international agreements that prohibit their use.As a result we obtain that the refrigerator in evaluating operating with ecological refrigerant, compared with R-12 refrigerant source, stable thermodynamic conditions operation and lower power consumption compressor, for all load conditions and extended periods of operation is achieved. Therefore, one of the most convenient solutions from a socioeconomic view point, it is only replacing CFC refrigerant used in the refrigerator (old), making the appropriate dosage of ecological coolant and lubrication oil-fluidization Keywords.- Domestic refrigeration, CFC refrigerant, HFC refrigerant, Ozone layer, Energy efficiency, Reliability, Economy.


Author(s):  
Srinivas Garimella ◽  
Biswajit Mitra ◽  
Ulf C. Andresen ◽  
Yirong Jiang ◽  
Brian M. Fronk

2009 ◽  
Vol 4 (1) ◽  
pp. 47-56
Author(s):  
Makoto GOTO ◽  
Koji TANIFUJI ◽  
Masahiro FUJITA ◽  
Tomohiro YAMAUCHI ◽  
Satoshi OHUCHIDA ◽  
...  

2007 ◽  
Vol 73 (725) ◽  
pp. 291-297 ◽  
Author(s):  
Makoto GOTO ◽  
Koji TANIFUJI ◽  
Masahiro FUJITA ◽  
Tomohiro YAMAUCHI ◽  
Satoshi OHUCHIDA ◽  
...  

2005 ◽  
Vol 128 (1) ◽  
pp. 218-220 ◽  
Author(s):  
Roger Tuomas ◽  
Ove Isaksson

A high-pressure chamber is used to study lubricant compressibility when refrigeration oil is diluted by refrigerant. The tested lubricant in this work is a POE (polyol ester) oil, POE diluted with nonchlorinated (HFC) refrigerant R-134a, a naphthenic mineral oil, and the mineral oil diluted with the chlorinated (HCFC) refrigerant R-22. The high-pressure chamber experiments show that by adding 20 wt% of R-134a to the polyol ester oil, the stiffness of the lubricant increases by approximately 38 wt% at 1 GPa and is much higher than for R-22 and mineral oil.