extended field of view
Recently Published Documents


TOTAL DOCUMENTS

169
(FIVE YEARS 15)

H-INDEX

21
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Mariana C. Potcoava ◽  
Christopher J. Mann ◽  
Simon T. Alford ◽  
Jonathan Art

2021 ◽  
Author(s):  
RITIKA MALIK ◽  
ravikrishnan elangovan ◽  
Kedar Khare

2021 ◽  
Author(s):  
Gabriel Paiva Fonseca ◽  
Matthias Baer‐Beck ◽  
Eric Fournie ◽  
Christian Hofmann ◽  
Ilaria Rinaldi ◽  
...  

2021 ◽  
Vol 22 (1) ◽  
Author(s):  
A. Wayne Johnson ◽  
Lauren Adams ◽  
Jade B. Kho ◽  
Daniel M. Green ◽  
Nicolas B. Pace ◽  
...  

Abstract Background The strength and size of core muscles, including the abdominal muscles, are crucial to proper function in most activities. Therefore, it is important to reliably assess these characteristics. Our primary objective was to determine if the length, thickness and cross-sectional area of the transversus abdominis (TrA) can be visualized independently from the internal and external abdominal oblique muscles using extended field of view ultrasound imaging at rest and with contraction and to establish its intra- and inter-tester reliability. Methods Twenty-six individuals were recruited to participate in the study (20 F, 6 M), average age 24.0 years (SD 9.4), height 170.7 cm (SD 8.6) and weight 63.9 kg (SD 9.0). From this total number of participants, two groups of 16 randomly selected participants were assessed to determine intra- and inter-tester reliability respectively. Extended field of view ultrasound images were obtained at three vertebral levels during rest and contraction in the side lying position for both the right and left sides of the trunk. Results Excellent intra-tester and inter-tester reliability was seen (ICC range of 0.972 to 0.984). The overall average percent standard error of the measurement for all measurements and locations was approximately 4%. The overall average minimal difference for the thickness measurement for the resting and contraction conditions combined were as follows: intratester 0.056 (0.014) cm and intertester 0.054 (0.017) cm, for area intratester 0.287 (0.086) cm2 and intertester 0.289 (0.101) cm2 and for length intratester 0.519 (0.097) cm and intertester 0.507 (0.085) cm. Conclusions Extended field of view ultrasound imaging is an effective method of reliably capturing clear images of the TrA during rest and contraction. It provides an efficient mechanism for the analysis of muscle morphology by being able to measure the cross-sectional area, thickness, and length on one image. This methodology is recommended for studies investigating TrA function and training.


2021 ◽  
Vol 7 (3) ◽  
pp. 54
Author(s):  
Van Nguyen ◽  
Joaquim G. Sanctorum ◽  
Sam Van Van Wassenbergh ◽  
Joris J. J. Dirckx ◽  
Jan Sijbers ◽  
...  

Compared to single source systems, stereo X-ray CT systems allow acquiring projection data within a reduced amount of time, for an extended field-of-view, or for dual X-ray energies. To exploit the benefit of a dual X-ray system, its acquisition geometry needs to be calibrated. Unfortunately, in modular stereo X-ray CT setups , geometry misalignment occurs each time the setup is changed, which calls for an efficient calibration procedure. Although many studies have been dealing with geometry calibration of an X-ray CT system, little research targets the calibration of a dual cone-beam X-ray CT system. In this work, we present a phantom-based calibration procedure to accurately estimate the geometry of a stereo cone-beam X-ray CT system. With simulated as well as real experiments, it is shown that the calibration procedure can be used to accurately estimate the geometry of a modular stereo X-ray CT system thereby reducing the misalignment artifacts in the reconstruction volumes.


2021 ◽  
Vol 6 (1) ◽  
pp. 26
Author(s):  
Eleftherios Kellis ◽  
Athina Konstantinidou ◽  
Athanasios Ellinoudis

Muscle morphology is an important contributor to hamstring muscle injury and malfunction. The aim of this study was to examine if hamstring muscle-tendon lengths differ between various measurement methods as well as if passive length changes differ between individual hamstrings. The lengths of biceps femoris long head (BFlh), semimembranosus (SM), and semitendinosus (ST) of 12 healthy males were determined using three methods: Firstly, by identifying the muscle attachments using ultrasound (US) and then measuring the distance on the skin using a flexible ultrasound tape (TAPE-US). Secondly, by scanning each muscle using extended-field-of view US (EFOV-US) and, thirdly, by estimating length using modelling equations (MODEL). Measurements were performed with the participant relaxed at six combinations of hip (0°, 90°) and knee (0°, 45°, and 90°) flexion angles. The MODEL method showed greater BFlh and SM lengths as well as changes in length than US methods. EFOV-US showed greater ST and SM lengths than TAPE-US (p < 0.05). SM length change across all joint positions was greater than BFlh and ST (p < 0.05). Hamstring length predicted using regression equations is greater compared with those measured using US-based methods. The EFOV-US method yielded greater ST and SM length than the TAPE-US method. SM showed the highest change in length at different hip and knee joint positions.


Sign in / Sign up

Export Citation Format

Share Document