finite element methodology
Recently Published Documents


TOTAL DOCUMENTS

77
(FIVE YEARS 4)

H-INDEX

13
(FIVE YEARS 0)

2021 ◽  
Vol 254 ◽  
pp. 106519
Author(s):  
J. N. Costa ◽  
P. Antunes ◽  
H. Magalhães ◽  
J. Pombo ◽  
J. Ambrósio

Crystals ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 998
Author(s):  
Guanjun Xu ◽  
Dongdong Jiao ◽  
Long Chen ◽  
Linbo Zhang ◽  
Jun Liu ◽  
...  

Ultra-stable optical cavities (USOCs) as fragile precision instruments have many important applications in space. In order to protect them from being damaged during a rocket launch, we analyzed a USOC by means of finite element methodology. The shock acceleration limits that the USOC can withstand in different directions and under various conditions are given. To increase the shock acceleration limit, the midplane thickness and the fixed hole diameter should be selected to be as high as possible. It is worth noting that the launch direction of the USOC should be selected as the horizontal direction, for which the shock acceleration limit that the USOC can withstand is approximately two times that of the vertical direction. In this paper, results provide guidance for the design of USOCs for space applications, especially the design to prevent the damage caused by a shock. The method could then be applied to other space optical cavities, providing a tool to improve the effect of shock at high accelerations.


2020 ◽  
Author(s):  
◽  
Marcos Choucino

Magnetic Resonance Imaging (MRI) scanners have become an essential tool in the medi-cal industry due to their ability to produce high resolution images of the human body. To generate an image of the body, MRI scanners combine strong static magnetic fields with transient gradient magnetic fields. The interaction of these magnetic fields with the con-ducting components present in superconducting MRI scanners gives rise to an important problem in the design of new MRI scanners. The transient magnetic fields give rise to the appearance of eddy currents in conducting components. These eddy currents, in turn, result in electromagnetic stresses, which cause the conducting components to deform and vibrate. The vibrations are undesirable as they lead to a deterioration in image quality (with image artefacts) and to the generation of noise, which can cause patient discomfort. The eddy currents, in addition, lead to heat being dissipated and deposited into the cryo-stat, which is filled with helium in order to maintain the coils in a superconducting state. This deposition of heat can cause helium boil off and potentially result in a costly magnet quench. Understanding the mechanisms involved in the generation of these vibrations and the heat being deposited into the cryostat are, therefore, key for a successful MRI scanner design. This involves the solution of a coupled magneto-mechanical problem, which is the focus of this work.In this thesis, a new computational methodology for the solution of three-dimensional (3D) magneto-mechanical coupled problems with application to MRI scanner design is presented. To achieve this, first an accurate mathematical description of the magneto-mechanical coupling is presented, which is based on a Lagrangian formulation and the assumption of small displacements. Then, the problem is linearised using an AC-DC splitting of the fields, and a variational formulation for the solution of the linearised prob-lem in a time-harmonic setting is presented. The problem is then discretised using high order finite elements, where a combination of hierarchical H1 and H(curl) basis func-tions is used. An efficient staggered algorithm for the solution of the coupled system is proposed, which combines the DC and AC stages and makes use of preconditioned iter-ative solvers when appropriate. This finite element methodology is then applied to a set of challenging academic and industrially relevant problems in order to demonstrate its accuracy and efficiency.This finite element methodology results in the accurate and efficient solution of the magneto-mechanical problem of interest. However, in the design stage of a new MRI scanner, this coupled problem must be solved repeatedly for varying model parameters such as frequency or material properties. Thus, even if an efficient finite element solver is available for the solution of the coupled problem, the need for these repeated simulations result in a bottleneck in terms of computational cost, which leads to an increase in design time and its associated financial implications. Therefore, in order to optimise this process, the application of Reduced Order Modelling (ROM) techniques is considered. A ROM based on the Proper Orthogonal Decomposition (POD) method is presented and applied to a series of challenging MRI configurations. The accuracy and efficiency of this ROM is demonstrated by performing comparisons against the full order or high fidelity finite element software, showing great performance in terms of computational speed-up, which has major benefits in the optimisation of the design process of new MRI scanners.


Sign in / Sign up

Export Citation Format

Share Document