2020 ◽  
Vol 11 (3) ◽  
pp. 187-195 ◽  
Author(s):  
P. Rogalski

The paper presents a measuring stand designed and built for testing direct and alternating current properties of power transformers basic insulation component i.e. electrotechnical pressboard impregnated with transformer oil. Measurements of direct and alternating current parameters are performed using the frequency domain spectroscopy and polarization depolarization current methods.The measuring station includes a specially developed climatic chamber which is characterized by high accuracy of temperature stabilization and maintenance during several dozen hours of measurements. The uncertainty of temperature maintaining during several dozen hours of measurements does not exceed ± 0.01 °C. The computer software developed to control the station allows for remote measurements, changes in supply voltage and temperature settings and acquisition of the obtained results. A new type of measuring capacitor was developed and manufactured, the structure of which significantly reduces the chance of samples contamination during measurements. By increasing the accuracy of temperature stabilization during measurements, the resolution of measurement temperatures was increased, at which it is possible to perform measurements with the frequency domain spectroscopy and polarization depolarization current methods. This allowed to reduce the step of measurement temperature change and thus to increase the accuracy of determining the activation energy of the measured parameters.The article also contains basic information on the analysis of the direct and alternating current electrical parameters of the composite electrotechnical pressboard-mineral oil-water nanoparticles. The results of several direct and alternating current parameters measurements of a transformer oil impregnated pressboard sample with a moisture content of (5.2 ± 0.1) % by weight obtained by the use of a measuring stand are presented as examples. 


2020 ◽  
Vol 11 (2) ◽  
pp. 140-147 ◽  
Author(s):  
C. Kozak

The paper presents a new test stand for ivestigating the rate of penetration of transformer oil through electrotechnical pressboard. The stand consists of a pipe, to the lower end of which is glued a pressboard plate. The pipe is filled with insulating oil. A mirror is placed under the plate, which directs its image to the lens of the camera, which takes a series of photographs at a given time interval. After being saturated with the insulating oil, the pressboard changes colour from light to dark yellow. The absorbing time is defined as the time in which a dark yellow spot appears on the lower light surface of the pressboard after the pipe is filled with oil.A new way of determining capillary diameters has been developed when the number of capillaries is unknown and the volume of liquid flowing through them is not measurable. The distribution of the times of penetration of transformer oil through 2 mm thick electrotechnical pressboard was determined, the values of which range from about 220 min to about 550 min. It was found that the radii of capillaries through which the insulating oil penetrates are within the range from about 45 nm to about 70 nm. Due to the structure of the pressboard, which consists of cellulose fibres, arranged more or less tightly, there are capillaries in the structure of the board, each of which has sections of varying lengths of radii. This means that short sections of a single capillary can have radii both smaller than 45 nm and larger than 70 nm.The developed stand and the new analysis method can be used for testing various porous materials for penetration by various liquids. 


2018 ELEKTRO ◽  
2018 ◽  
Author(s):  
Przemyslaw Rogalski ◽  
Pawel Zukowski ◽  
Milan Sebok ◽  
Miroslav Gutten

Sign in / Sign up

Export Citation Format

Share Document