urban canopy parameterizations
Recently Published Documents


TOTAL DOCUMENTS

5
(FIVE YEARS 1)

H-INDEX

2
(FIVE YEARS 0)

2021 ◽  
Author(s):  
Ge Cheng ◽  
David Grawe ◽  
K. Heinke Schlünzen

<p>Nudging is a simple method that aims to dynamically adjust the model toward the observations by including an additional feedback term in the model governing equation. This method is widely applied in data assimilation due to its simple implementation and reasonable model results. The basic concept of nudging is similar to that of urban canopy parameterization, in which additional terms are usually added in the conservation equations of momentum and energy aiming to simulate the canopy effects. However, few studies have investigated the implementation of nudging methods in urban canopy parameterizations. In this study we developed a multi-layer urban canopy parameterization (UCP) by using a nudging approach to represent the impacts of vegetated urban canopies on temperatures and winds in mesoscale models.</p><p>The difficulty of developing UCP by using a nudging method lies in defining appropriate values for the nudging coefficients and the forcing fields (e.g. indoor temperature fields for temperature nudging). To determine nudging coefficients, we use three major urban canopy morphological parameters: building height, frontal area density and building density. The ranges of these parameters are taken from the values for the Local Climate Zones datasets, in our case for the city of Hamburg. The UCP is employed in the three -dimensional atmospheric mesoscale model METRAS. Results show that this UCP can well simulate wind-blocking effects induced from obstacles as buildings and trees and urban heat island phenomenon for cities. Thus, nudging is an efficient and effective method that can be used for urban canopy parameterizations. However, as well known for nudging, it is not conserving energy. Therefore, we investigated the energy loss by tracking the reduced kinetic energy and internal energy. The UCP and model results will be presented.</p>


2011 ◽  
Vol 50 (5) ◽  
pp. 1107-1128 ◽  
Author(s):  
Francisco Salamanca ◽  
Alberto Martilli ◽  
Mukul Tewari ◽  
Fei Chen

AbstractIn the last two decades, mesoscale models (MMs) with urban canopy parameterizations have been widely used to study urban boundary layer processes. Different studies show that such parameterizations are sensitive to the urban canopy parameters (UCPs) that define the urban morphology. At the same time, high-resolution UCP databases are becoming available for several cities. Studies are then needed to determine, for a specific application of an MM, the optimum degree of complexity of the urban canopy parameterizations and the resolution and details necessary in the UCP datasets. In this work, and in an attempt to answer the previous issues, four urban canopy schemes, with different degrees of complexity, have been used with the Weather Research and Forecasting (WRF) model to simulate the planetary boundary layer over the city of Houston, Texas, for two days in August 2000. For the UCP two approaches have been considered: one based on three urban classes derived from the National Land Cover Data of the U.S. Geological Survey and one based on the highly detailed National Urban Database and Access Portal Tool (NUDAPT) dataset with a spatial resolution of 1 km2. Two-meter air temperature and surface wind speed have been used in the evaluation. The statistical analysis shows a tendency to overestimate the air temperatures by the simple bulk scheme and underestimate the air temperatures by the more detailed urban canopy parameterizations. Similarly, the bulk and single-layer schemes tend to overestimate the wind speed while the multilayer schemes underestimate it. The three-dimensional analysis of the meteorological fields revealed a possible impact (to be verified against measurements) of both the urban schemes and the UCP on cloud prediction. Moreover, the impact of air conditioning systems on the air temperature and their energy consumption has been evaluated with the most developed urban scheme for the two simulated days. During the night, this anthropogenic heat was responsible for an increase in the air temperature of up to 2°C in the densest urban areas, and the estimated energy consumption was of the same magnitude as energy consumption obtained with different methods when the most detailed UCP database was used. On the basis of the results for the present case study, one can conclude that if the purpose of the simulation requires only an estimate of the 2-m temperature a simple bulk scheme is sufficient but if the purpose of the simulation is an evaluation of an urban heat island mitigation strategy or the evaluation of the energy consumption due to air conditioning at city scale, it is necessary to use a complex urban canopy scheme and a detailed UCP.


2005 ◽  
Vol 5 (6) ◽  
pp. 11183-11213 ◽  
Author(s):  
A. Mahura ◽  
S. Leroyer ◽  
P. Mestayer ◽  
I. Calmet ◽  
S. Dupont ◽  
...  

Abstract. The large eddy simulations employing the SUBMESO model with the urban soil layer model SM2-U were performed for the model domain covering the Danish Island of Sealand and including the Copenhagen metropolitan area. Monthly and diurnal cycle variability were studied for the net radiation, sensible and storage heat fluxes, surface's temperatures, and others. These were evaluated for selected urban vs. non urban related types of covers/surfaces and urban districts such as city center, high buildings, industrial, and residential. Results showed strong effects of urban features on temporal and spatial variability. They are useful and applicable for verification of numerical weather prediction models and development of urban canopy parameterizations.


Sign in / Sign up

Export Citation Format

Share Document