neurally adjusted ventilator assist
Recently Published Documents


TOTAL DOCUMENTS

16
(FIVE YEARS 2)

H-INDEX

4
(FIVE YEARS 0)

Author(s):  
Theodore Dassios ◽  
Aggeliki Vervenioti ◽  
Gabriel Dimitriou

Abstract Our aim was to summarise the current evidence and methods used to assess respiratory muscle function in the newborn, focusing on current and future potential clinical applications. The respiratory muscles undertake the work of breathing and consist mainly of the diaphragm, which in the newborn is prone to dysfunction due to lower muscle mass, flattened shape and decreased content of fatigue-resistant muscle fibres. Premature infants are prone to diaphragmatic dysfunction due to limited reserves and limited capacity to generate force and avoid fatigue. Methods to assess the respiratory muscles in the newborn include electromyography, maximal respiratory pressures, assessment for thoraco-abdominal asynchrony and composite indices, such as the pressure–time product and the tension time index. Recently, there has been significant interest and a growing body of research in assessing respiratory muscle function using bedside ultrasonography. Neurally adjusted ventilator assist is a novel ventilation mode, where the level of the respiratory support is determined by the diaphragmatic electrical activity. Prolonged mechanical ventilation, hypercapnia and hypoxia, congenital anomalies and systemic or respiratory infection can negatively impact respiratory muscle function in the newborn, while caffeine and synchronised or volume-targeted ventilation have a positive effect on respiratory muscle function compared to conventional, non-triggered or pressure-limited ventilation, respectively. Impact Respiratory muscle function is impaired in prematurely born neonates and infants with congenital anomalies, such as congenital diaphragmatic hernia. Respiratory muscle function is negatively affected by prolonged ventilation and infection and positively affected by caffeine and synchronised compared to non-synchronised ventilation modes. Point-of-care diaphragmatic ultrasound and neurally adjusted ventilator assist are recent diagnostic and therapeutic technological developments with significant clinical applicability.


2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Julia Harris ◽  
Shane M Tibby ◽  
Ruth Endacott ◽  
Jos M. Latour

2019 ◽  
Vol 127 (1) ◽  
pp. 264-271 ◽  
Author(s):  
Annemijn H. Jonkman ◽  
Diana Jansen ◽  
Suvarna Gadgil ◽  
Christiaan Keijzer ◽  
Armand R. J. Girbes ◽  
...  

The patient-ventilator breath contribution (PVBC) index estimates the relative contribution of the patient to total tidal volume (Vtinsp) during mechanical ventilation in neurally adjusted ventilator assist mode and has been used to titrate ventilator support. The reliability of this index in ventilated patients is unknown and was investigated in this study. PVBC was calculated by comparing tidal volume (Vtinsp) and diaphragm electrical activity (EAdi) during assisted breaths (Vtinsp/EAdi)assist and during unassisted breaths (Vtinsp/EAdi)no-assist. Vtinsp was normalized to peak EAdi (EAdipeak) using 1) one assisted breath, 2) five consecutive assisted breaths, or 3) five assisted breaths with matching EAdi preceding the unassisted breath (N1PVBC2, X5PVBC2, and [Formula: see text], respectively). In addition, PVBC was calculated by comparing only Vtinsp for breaths with matching EAdi (PVBCβ2). Test-retest reliability of the different PVBC calculation methods was evaluated with the intraclass correlation coefficient (ICC) using five repeated PVBC maneuvers performed with a 1-min interval. In total, 125 PVBC maneuvers were analyzed in 25 patients. ICC [95% confidence interval] values were 0.46 [0.23–0.66], 0.51 [0.33–0.70], and 0.42 [0.14–0.69] for N1PVBC2, X5PVBC2, [Formula: see text], respectively. Complex waveform analyses showed that insufficient EAdi filtering by the ventilator software affects reliability of PVBC calculation. With our new EAdi-matching techniques reliability improved (PVBCβ2 ICC: 0.78 [0.60–0.90]). We conclude that current techniques to calculate PVBC exhibit low reliability and that our newly developed criteria and estimation of PVBC—using Vtinsp of assisted breaths and unassisted breaths with matching EAdi—improves reliability. This may help implementation of PVBC in clinical practice. NEW & NOTEWORTHY The patient-ventilator breath contribution (PVBC) index estimates the relative contribution of the patient to tidal volume generated by the patient and the mechanical ventilator during mechanical ventilation in neurally adjusted ventilator assist mode. It could be used to titrate ventilator support and thus to limit development of diaphragm dysfunction in intensive care unit patients. Currently available methods for bedside assessment of PVBC are unreliable. Our newly developed criteria and estimation of PVBC largely improve reliability and help to quantify patient contribution to total inspiratory effort.


Author(s):  
Yohan Soreze ◽  
Emmanuelle Motte ◽  
Valentina Dell’Orto ◽  
Nadya Yousef ◽  
Daniele De Luca