oxford unicompartmental knee arthroplasty
Recently Published Documents


TOTAL DOCUMENTS

73
(FIVE YEARS 7)

H-INDEX

19
(FIVE YEARS 0)

2021 ◽  
Vol 6 (10) ◽  
pp. 850-860
Author(s):  
Stein J. Janssen ◽  
Iris van Oost ◽  
Stefan J.M. Breugem ◽  
Rutger C.I. van Geenen

Unicompartmental knee arthroplasty (UKA) has several advantages over total knee arthroplasty; however, in many reports, the risk of revision remains higher after UKA. Many reasons for failure of UKA exist. Successful treatment starts with accurate assessment of the symptomatic UKA as a specific mode of failure requires a specific solution. A structured and comprehensive evaluation aids assessment of the symptomatic UKA. This review provides an overview of the causes for a symptomatic medial UKA, its risk factors, diagnostic modalities that can be used, and briefly discusses treatment options. Cite this article: EFORT Open Rev 2021;6:850-860. DOI: 10.1302/2058-5241.6.200105


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Guangzhong Yang ◽  
Xufeng Jiao ◽  
Qianli Li ◽  
Zheng Li ◽  
Shuai An ◽  
...  

Abstract Background Hybrid Oxford unicompartmental knee arthroplasty (OUKA) consists of cementless femoral prostheses and cemented tibial prostheses. Although a hybrid OUKA has been used in clinical practice, the clinical outcome has not been reported. The purpose of this study was to compare the short-term clinical outcomes and rate of residual bone cement extrusion between hybrid and cemented prostheses and analyse the possible reasons for differences between outcomes. Methods A total of 128 knees (118 patients) with end-stage osteoarthritis were included in this study, of which underwent consecutive operations using unicondylar Oxford phase 3 implants from July 2017 and September 2019 in our centre. Follow-up was performed at 6 weeks, 3 and 6 months, 1 year and every year after operation, and complications and changes in the Oxford knee score (OKS) were recorded. The OKS of the two groups was analysed by the generalized estimating equation approach. Prosthesis-based standard fluoroscopy was performed in a timely manner after each operation, and the rate of residual cement extrusion of the two groups was estimated using T-tests and a multivariate regression analysis. Results Excluding the cases that lost follow-up, a total of 120 knees (65 in hybrid group and 55 in cemented group) were included in the analysis. There was no statistically significant difference in patient characteristics between the two groups (p > 0.05). The average follow-up time was 23.4 months (and ranged from 12 to 38 months). As of the last follow-up, there were no complications, such as dislocation, fracture, prosthesis loosening and subsidence, but one patient in the cemented group experienced symptoms caused by residual loose cement. Postoperative OKS in both groups improved significantly (p < 0.001). There was no significant difference in the OKS at any point during the follow-up or in the improvement of the OKS between the two groups (p > 0.05). Residual cement was mainly extruded behind the tibial prosthesis. The rate of hybrid periprosthetic residual cement extrusion was significantly lower in the hybrid group than in the cemented group, and the difference was statistically significant (OR = 3.38; p = 0.014). Conclusions Hybrid OUKA is as effective as cemented OUKA in the short term after operation and can significantly reduce the residual cement extrusion rate around the tibial prosthesis.


2021 ◽  
Author(s):  
Kohei Kawaguchi ◽  
Hiroshi Inui ◽  
Shuji Taketomi ◽  
Ryota Yamagami ◽  
Kenichi Kono ◽  
...  

Abstract Background: The choice of mobile bearing (MB) thickness is essential for obtaining successful results after mobile-bearing Oxford unicompartmental knee arthroplasty (UKA). This study aimed to investigate the effects of a 1-mm difference in bearing thickness on intraoperative MB movement and intraoperative knee kinematics in Oxford UKAs.Methods: We prospectively investigated the intraoperative MB movement and knee kinematics of 25 patients who underwent Oxford UKAs when surgeons didn’t know which bearing thickness to choose with 1-mm difference. A trial tibial component that was scaled every 2 mm was used to measure the intraoperative MB movement, and the tibial internal rotation relative to the femur and the knee varus angle was simultaneously evaluated using the navigation system as the knee kinematics. We separately evaluated sets of two MB thicknesses with 1-mm differences, and we compared the intraoperative parameters at maximum extension; 30º, 45º, 60º, and 90º flexion; and maximum flexion between the thicker MB (thick group) and the thinner MB (thin group).Results: The MB in the thin group was located significantly posteriorly at 90º flexion compared with that in the thick group; however, there were no differences at the other flexion angles. There was significantly less tibial internal rotation in the thin group at 90º flexion than that in the thick group; however, there were no differences at the other flexion angles. The knee varus angles in the thick group were significantly smaller than those in the thin group by approximately one degree at all angles other than at 30º and 45º flexion. Conclusion: The thicker MB could bring the less posterior MB movement and the more tibial internal rotation at 90º flexion, additionally the valgus correction angle in the thicker MB should be paid attention. These results could help surgeons to decide the thickness of MBs when they wonder the thickness of MB.


Author(s):  
Riccardo D'Ambrosi ◽  
Manuel J. de S.V. da Silva ◽  
João L. M. Moura ◽  
Ilaria Mariani ◽  
Luca D. Serrao ◽  
...  

AbstractThe aim of the study is to evaluate whether the use of the new instrumentation Microplasty (MP) improves component positioning and the reliability of the surgical technique, reducing the implant outliers from the recommended range and providing a more accurate resection, while avoiding insufficient or excessive tibial resection and clinical scores. We prospectively analyzed clinical and radiographic outcomes of three consecutive cohorts for a total of 227 implants at a minimum follow-up of 36 months. The first cohort consisted of 67 Oxford unicompartmental knee arthroplasty (OUKA), using the phase III (Ph-III). The second cohort consisted of 136 OUKA, with the MP instrumentation. The third cohort consisted of 24 hypoallergenic OUKA, using the MP instrumentation (TiNbN). Postoperative alignment of the knee in the coronal and sagittal plane was measured using radiographs. No clinical differences were found among the three groups (p > 0.05). A significant difference was found on the slope between Ph-III and MP (p = 0.0005). Moreover, a significant difference was found in tibial angle and in tibial slope in arthroplasty with femoral size small (S), compared with size medium (M) or large (Ly) (tibia varus/valugs angle: p = 0.0484; tibial slope: p = 0.04). Similar results were found between small (AA, A, B) tibial size and large (C, D, E, F) tibial size for tibial varus/valgus (p = 0.03) angle and tibial slope (p = 0.003). A significant difference was found between Ph-III and MP in tibial slope in patients with body mass index (BMI) ≥25 kg/m2 (p = 0.0003). A positive correlation was noted between the femoral and tibial sizes and the tibial angle and the slope, and a negative correlation between weight and the tibial slope; furthermore, a positive correlation was found between Oxford knee score and radiographic angles. The MP instrumentation seems to be effective in determining the tibial cut and, particularly, improving the tibial slope, compared with Ph-III. The tibial slope is directly affected by the weight and measurements of the components, regardless of the instruments or the number of pegs, while clinical outcomes are correlated with implant position. This prospective comparative study reflects level of evidence II.


2021 ◽  
Author(s):  
Jirayu Paugchawee ◽  
Chaturong Pornrattanamaneewong ◽  
Pakpoom Ruangsomboon ◽  
Rapeepat Narkbunnam ◽  
Keerati Chareancholvanich

Abstract Background: Oxford unicompartmental knee arthroplasty (OUKA) yields favorable outcomes in patients with medial compartmental knee osteoarthritis; however, it remains unknown whether cemented or cementless OUKA fixation delivers better outcomes in Asian population. Accordingly, this study aimed to investigate the complications, reasons for reoperation, and 5-year prosthesis survival compared between cemented and cementless OUKA in Thai patients.Methods: A total of 466 cemented and 36 cementless OUKA that were performed during 2011-2015 with a minimum follow-up of five years were included. With reoperation for any reason as the endpoint, Kaplan-Meier analysis was performed to compare 5-year implant survival between groups. Complications, reasons for reoperation, and 90-day morbidity and mortality were compared between groups. Cox proportional hazards model was used to identify independent predictors of implant survival.Results: There was no significant difference in 5-year implant survival between the cemented and cementless groups (96.4% vs. 94.4%, p=0.375). The mean implant survival time was 113.0±0.8 and 70.8±1.9 months in the cemented and cementless groups, respectively (p=0.383). The most common reason for reoperation was bearing dislocation, and only one patient had 90-day morbidity. There was no significant difference between groups for complications or reasons for reoperation. No independent predictors of implant survival were identified in multivariate analysis.Conclusions: OUKA was shown to be a safe and durable reconstructive procedure in Thai patients with medial compartmental knee osteoarthritis. There was no significant difference in implant survival between the cemented and cementless groups during the 5-year follow-up, and no independent predictors of implant survival were identified. Trial registration: Thai Clinical Trials Registry, TCTR20200427004. Registered 27 April 2020 – Retrospectively registered.


The Knee ◽  
2020 ◽  
Vol 27 (6) ◽  
pp. 1721-1728
Author(s):  
Shiraz A. Sabah ◽  
Chin Tat Lim ◽  
Robert Middleton ◽  
Lennart von Fritsch ◽  
Nicholas Bottomley ◽  
...  

The Knee ◽  
2020 ◽  
Vol 27 (6) ◽  
pp. 1953-1962
Author(s):  
Jonathan Patrick Ng ◽  
Jason Chi Ho Fan ◽  
Wang Wai Chau ◽  
Chun Man Lau ◽  
Yik Cheung Wan ◽  
...  

Materials ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 4589
Author(s):  
Johannes Adrian Eckert ◽  
Ulrike Mueller ◽  
Tilman Walker ◽  
Martin Schwarze ◽  
Sebastian Jaeger ◽  
...  

The medial Oxford unicompartmental knee arthroplasty (OUKA) shows good survivorship, as well as clinical results. Aseptic loosening, however, remains one of the main reasons for revision and polyethylene debris is known to cause aseptic loosening. The role of bearing thickness in total as well as unicondylar knee arthroplasty has been the subject of controversial discussions, especially the longevity of lower thickness bearings in total knee arthroplasty was questioned. The purpose of this study was to assess the influence of bearing thickness on time to revision, damage pattern, penetration, and volumetric material loss. A cohort of 47 consecutively retrieved medial OUKA bearings was analyzed with conventional direct light microscopy applying the Hood damage analysis, as well as measuring the penetration depth. In this retrieval cohort, a difference on survival time, damage, penetration, as well as volumetric material loss could not be seen. We conclude that low as well as high thickness bearings can safely be used in OUKA without any relevant differences in terms of wear and damage.