gold ultramicroelectrode
Recently Published Documents


TOTAL DOCUMENTS

13
(FIVE YEARS 1)

H-INDEX

8
(FIVE YEARS 0)

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1811
Author(s):  
Sandra Enn D. Bahinting ◽  
Analiza P. Rollon ◽  
Sergi Garcia-Segura ◽  
Vince Carlo C. Garcia ◽  
Benny Marie B. Ensano ◽  
...  

The widespread presence of heavy metals in drinking water sources arises as a major health concern, particularly in developing countries. The development of low-cost and reliable detection techniques is identified as a societal need to provide affordable water quality control. Herein, a bismuth film-coated gold ultramicroelectrode array (BF-UMEA) was used for the detection of Pb(II) and Cd(II) in water samples via square wave anodic stripping voltammetry (SWASV). Experimental parameters such as deposition time, Bi(III) concentration, acetate buffer concentration, pH, square wave frequency, amplitude, and step potential were all varied to determine their effects on the current peak intensities of the target metal ions. Ten-fold excess in the concentration of interferences was found to cause a decrease in the stripping peak areas of Cd(II) and Pb(II) in the following order of magnitude: benzene < NaCl < Ni(II) < Cu(II). Using Box–Behnken design, the optimum SWASV parameters that provided maximum current peak areas were 14.76 Hz (frequency), 50.10 mV (amplitude), and 8.76 mV (step potential). The limits of detection of the as-prepared BF-UMEA were 5 and 7 µg L−1 for Pb(II) and Cd(II), respectively. These results demonstrate the potential use of a BF-UMEA in SWASV for the trace quantification of Pb(II) and Cd(II) in water samples.


2019 ◽  
Vol 21 (10) ◽  
pp. 5416-5423 ◽  
Author(s):  
Simon Rano ◽  
Christel Laberty-Robert ◽  
Kieu Ngo ◽  
Carlos M. Sánchez-Sánchez ◽  
Vincent Vivier

Transient electrochemical experiments associated with the collisions between hydrothermally synthesized LiCoO2 (LCO) nanoparticles/aggregates of different sizes and a polarized gold ultramicroelectrode (UME) were used as a new additive-free analytical tool applied to characterize Li ion insertion compounds.


Author(s):  
Manuel Gutierrez-Capitan ◽  
Antoni Baldi ◽  
Cecilia Jimenez-Jorquera ◽  
Cesar Fernandez-Sanchez ◽  
Raquel Gomez ◽  
...  

2007 ◽  
Vol 19 (4) ◽  
pp. 429-435 ◽  
Author(s):  
Olga González-García ◽  
Cristina Ariño ◽  
José Manuel Díaz-Cruz ◽  
Miquel Esteban

2006 ◽  
Vol 18 (3) ◽  
pp. 247-252 ◽  
Author(s):  
Olga Ordeig ◽  
Craig E. Banks ◽  
F. Javier del Campo ◽  
Francesc Xavier Muñoz ◽  
James Davis ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document