oscillographic method
Recently Published Documents


TOTAL DOCUMENTS

28
(FIVE YEARS 1)

H-INDEX

4
(FIVE YEARS 0)

2021 ◽  
Vol 410 ◽  
pp. 737-741
Author(s):  
Marina V. Koryachko ◽  
Danila E. Pshonkin ◽  
Arkady A. Skvortsov

The work is devoted to processes during melting of thin aluminium film on silicon surface in pulse current mode. An experiment was conducted to study the dynamics during the onset of the liquid phase on a metal film. Besides, the process of formation droplet localization zones is considered. The experimental part revealed critical current values ​ during an electrical explosion of thin metal films near the thermal shock source. Using the oscillographic method, the temperature profile of the metallization track is calculated.


Author(s):  
D. V. Vakulenko ◽  
L. O. Vakulenko ◽  
O. V. Kutakova

It is considered the application of oscillographic method, arterial oscillograms (at morphological, temporal and spectral methods). Indicated method makes it possible to assess the condition of specific (related to the regulation of vascular tone) and sympathoadrenal nonspecific mechanisms of adaptation on active orthostatic test. Application of oscillographic method during orthostatic test enables early detection of prenosological and premorbid conditions and assessing the reserve capacity of the organism to help doctor better plan preventive, diagnostic and therapeutic process.


2008 ◽  
Vol 26 (3) ◽  
pp. 133-139 ◽  
Author(s):  
John W Thompson ◽  
Mike Cummings

Our wish to know more about the paths taken by electrical currents in electroacupuncture (EA) with special reference to the heart, particularly in patients with an implanted pacemaker, prompted us to undertake this study. Using ourselves as subjects, we have developed a safe oscillographic method to detect, visualise and record the EA currents that avoids the use of equipment requiring mains electricity. After two trials with unsatisfactory equipment, we found that the newly developed model 3425 PicoScope™ (Pico Technology Ltd), with a four channel differential amplifier input connected to a laptop PC operating in battery mode, satisfied our criteria. With this recording system, we carried out two sets of experiments in which EA was provided by a Cefar acus4™ stimulator. The results confirm that the placement of a pair of acupuncture needles for EA can be used to predict the paths taken by the stimulating currents, and thus their areas of likely influence. When the needles are placed in closely adjacent acupuncture points in a limb, there is little or no detectable spread of the currents along the limb or into the chest. By contrast, when the needles are placed far apart, the electrical currents spread widely. Thus, when each of a pair of needles is placed in a point on opposite arms, the electrical currents recorded in the area of the pectoral muscles is of an order that might trigger an abnormal cardiac rhythm in a susceptible heart or activate a cardiac pacemaker incorporating an intracardiac defibrillator (ICD). Our results confirm the guidelines for EA safe practice recommended by the British Medical Acupuncture Society (BMAS) to avoid adverse events, ie EA should not be applied such that the current is likely to traverse the heart. We can now be confident that electric fields generated by pairs of needles below the knee or elbow do not create detectable currents in the chest. It is likely that similar results would be obtained with the use of transcutaneous electrical nerve stimulation (TENS) but this remains to be established by additional experiments.


1996 ◽  
Vol 39 (10) ◽  
pp. 1038-1040
Author(s):  
V. I. Zhavoronkov ◽  
V. A. Morozov

Sign in / Sign up

Export Citation Format

Share Document